AcuityBrands ARE2 and ARUE2 LED Post Top Lanterns Instruction Manual

June 9, 2024
AcuityBrands

AcuityBrands ARE2 and ARUE2 LED Post Top Lanterns
AcuityBrands ARE2 and ARUE2 LED Post Top Lanterns

LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the optic/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Optic/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe optic/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING
RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

WARNING
RISK OF BURN

  • Allow lamp/fixture to cool before handling.
    Do not touch enclosure or light source.

  • Do not exceed maximum wattage marked on luminaire label.

  • Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION
RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

CAUTION
RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Unless individual product specifications deem otherwise: Never connect an LED product directly to dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
  • Only use fixture in its intended location.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands

  • Indoor/Outdoor
    Lithonia Lighting
    Carandini
    Holophane
    RELOC

  • Indoor Lighting
    Gotham
    Mark Architectural Lighting
    Peerless
    Renaissance Lighting
    Winona Lighting

  • Outdoor Lighting
    American Electric Lighting
    Antique Street Lamps
    Hydrel
    Tersen

  • Controls
    DARK TO LIGHT
    Lighting Control & Design
    ROAM
    Sensor Switch
    Synergy

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2011 Acuity Brands Lighting, Inc. All rights reserved. 3/15/11

INTRODUCTION

Product Description.

This post top luminaire is designed with LED’s which do not require replacement.

The luminaire includes a plug-in electrical module that contains the photocontrol receptacle when specified. These modules are common to all luminaire styles in this series.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Alternate Information Sources.
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
866-759-1577

INSTALLATION

Tools and Material Required.
Table 1. Installation Tools and Materials

DESCRIPTION USE
Flat-end Screwdriver Installation of electrical wiring
1/4” Nut driver Electrical tray and reflector screws
1/8″ Allen Wrench Set screws (Mounting)
Torque Wrench Set screws

Luminaire Installation

  1. Place and level the luminaire on the pole.

  2. Orient Housing such that street aiming rib faces the street. See
    Figure 1
    Luminaire Installation

  3. Alternate tightening of the four set screws (See Figure 1) will assist in centering the luminaire on the post capital. Tighten the four set screws to 45-50 inch – pounds. (If the GV1A73 accessory is included; follow that torque specification for that part).

  4. Remove latch screw and latch and lift LED cover assembly back to gain access to the electrical tray and connections. Be cautious not to damage any component on this circuit board. See Figure 2.

  5. Disconnect the main power quick-disconnect and photo control circuit (If equipped with photo control option) and secure cover to remain in the open position. See Figure 2.
    Luminaire Installation

  6. Remove optic.

  7. Loosen reflector screws and remove reflector.

  8. Loosen two keyway screws, then turn and remove electrical tray; gently lay on its side to allow driver bracket to rest between arms of housing. Figure 3 shows electrical tray removed for clarity.

  9. Insert the electrical supply wiring into the luminaire wiring chamber through the center slot in the provided gasket. See Figure 3.
    Luminaire Installation

  10. Wire incoming leads to electrical tray accordingly. Connect incoming ground wire to ground wire attached to inside of wiring chamber. Carefully place connections in wiring chamber for future access.

  11. For units equipped with 0-10V dimming, locate the gray and violet leads coming from the driver. If the unit is to be connected to dimming control gear (not included), trim, strip and connect these leads per the dimming control gear manufacturer’s instructions. The violet lead is positive, and the gray lead is negative. If the unit is not to be connected to dimming control gear, leave the leads individually capped.

  12. Replace electrical tray on keyway slots, twist clock-wise and tighten screws

  13. Re-install reflector and tighten reflector screws.
    CAUTION
    LEADS USED FOR DIMMING CONTROLS ARE TO BE SEPARATED FROM MAIN POWER CONDUCTORS IN A MANNER TO SATISFY STATE AND LOCAL CODES

  14. Re-install optic.

  15. Orient “street side” on optic with street side rib on housing. See Figure 4.
    Luminaire Installation

  16. Orient “street side” and raised rib on heat sink with latch on cover. See Figure 5. Letter “A” on heat sink will face “street side” on optic and street side rib.
    Luminaire Installation

  17. Close LED cover assembly while ensuring no leads are pinched. Engage and secure the latch.

  18. Units supplied with a photo control option require a shorting plug or a twist lock photo control to be installed. Install the device by twisting it clockwise. See Figure 1.
    CAUTION
    A PHOTO CONTROL THAT MEETS THE REQUIREMENTS OF ANSI C136.10 AND WITH A CLEAR WINDOW ON THE SIDE THAT EXPOSES THE PHOTOCELL MUST BE USED.

  19. Energize the unit and check for proper operation

MAINTENANCE

Cleaning

  1. Make sure the unit is de-energized.
  2. Wipe off exterior dirt and debris using a soft, clean cloth.
    CAUTION
    DO NOT USE ABRASIVE CLEANSERS ON OPTICAL SURFACES. THEIR USE MAY RESULT IN THE LOSS OF OPTICAL EFFICIENCY.

Electrical Component Replacement

  1. To replace photocontrol. (If provided) Make sure the unit is de-energized. Twist counterclockwise and remove. Replace with equivalent photocontrol.

  2. For all other electrical parts- Make sure the unit is deenergized. Open housing by unscrewing and removing latch and latch screw (Figure 1). Disconnect main power quick disconnect and photo control disconnect (if applicable) and secure LED cover assembly in a way to prevent falling and/ or shock. (Or remove and place on a solid horizontal work bench).
    Remove the reflector by loosening (2) screws. See Figure 3.

  3. To replace LED driver. Make sure the unit is de-energized.
    Loosen and remove electrical tray to access parts. Disconnect input and output via quick disconnects and remove (2) mounting screws.
    Replace with Holophane approved driver. See Figure 6. If no other components are to be replaced go to Section 3.2.6

  4. Replacement of surge protector. Disconnect quick disconnect plug coming from terminal and quick disconnect going to optical compartment. Remove SPD SCREW connecting the surge protector to the plate; retain screws for re-installation.

  5. For standard surge units, remove the screw from mounting bracket and slide surge protector through opening in mounting bracket.
    Replace with Holophane approved device. See Figure 4.

  6. Bundle and secure the wiring in a manner like the way it was originally secured to avoid pinching of wires when re-installing the module into the housing.

  7. Replace electrical tray on keyway slots, twist clock-wise and tighten screws.

  8. Replace reflector (See Figure 1) and reconnect wiring harness(s), LED cover, latch and latch screw.
    HARNESS NOTES
    Any slack in the harnesses should neatly be pushed through the center opening in the lower reflector as the cover is closed.

  9. Energize the unit and check for proper operation.

Field Adjustable Output Module

The Field Adjustable Output (AO) module is an onboard device that adjusts the light output and input wattage to meet site specific requirements, allowing a single fixture configuration to be flexibly applied in many different applications. The following data tables are for the AS/MVOLT and AH/HVOLT voltage options.
Field Adjustable Output Module

P10 – AS/MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 76%
3| 63%| 64%
2| 52%| 54%
1| 39%| 42%
P20 – AS/MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 76%
3| 63%| 64%
2| 52%| 54%
1| 39%| 42%
P30 – AS/MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 74%
3| 64%| 62%
2| 52%| 51%
1| 40%| 39%
P40 – AS/MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 74%
3| 64%| 62%
2| 52%| 51%
1| 40%| 39%
P50 – AS/MVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 89%| 87%
4| 78%| 74%
3| 66%| 61%
2| 54%| 50%
1| 41%| 38%
P10 – AH/HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 63%| 64%
2| 52%| 53%
1| 39%| 41%
P20 – AH/HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 63%| 64%
2| 52%| 53%
1| 39%| 41%
P30 – AH/HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 64%| 63%
2| 52%| 51%
1| 40%| 40%
P40 – AH/HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 88%| 88%
4| 76%| 75%
3| 64%| 63%
2| 52%| 51%
1| 40%| 40%
P50 – AH/HVOLT ONLY

AO Position| % Lumens| % Wattage
8| 100%| 100%
7| 100%| 100%
6| 100%| 100%
5| 89%| 88%
4| 78%| 75%
3| 66%| 63%
2| 54%| 51%
1| 41%| 39%

LIMITED WARRANTY AND LIMITATION OF LIABILITY

The Holophane limited warranty and limitation of liability is published in the “Terms and Conditions” section of the current Holophane buyer’s guide, and is available from your local Holophane sales representative.

CUSTOMER SERVICE

LOGO
Acuity Brands Lighting, Inc.
3825 Columbus Rd SW, Granville, OH 43023
IM-433-A, 12/18/19 ©2019 Acuity Brands Lighting Inc.,
All Rights Reserved
Visit our web site at www.holophane.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AcuityBrands User Manuals

Related Manuals