NetWaySP4P Fiber Optic Transceivers Installation Guide
- June 4, 2024
- Netway
Table of Contents
Optic Transceivers
Installation Guide
NetWaySP4P Series
Fiber Optic Transceivers with Built-in Power Supplies
Models Include: NetWaySP4P
– 4-port Fiber Optic Transceiver with Built-in Power Supply for composite
Fiber (Powered) Cable
NetWaySP4P2
– 4-port Fiber Optic Transceiver with Power-Limited Outputs for Composite
Fiber (Powered) Cable
Installation Guide
DOC#: NETSP Rev. 020217
More than just power. TM
Installing Company: ___ Service Rep. Name:
Address: _____ Phone #:
Overview
Altronix NetWaySP4P/NetWaySP4P2 Fiber Optic Transceivers provide four (4) 1Gb SFP ports and four (4) ports for up to 120W per port to be transmitted over composite fiber (powered) cable (fiber + copper combined) to NetWay Spectrum PoE Hardened Switches. NetWaySP4P/NetWaySP4P2 can be used for standard fiber cable applications as well.
Features
Agency Listings:
-
UL/cUL UL 60950-1 (Information Technology Equipment).
-
European Conformity.
Input: -
115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2A.
Power:
NetWaySP4
- Four (4) 56VDC non-power-limited outputs up to 120W max. full power per port. Total power: 240W.
- IEEE 802.3af and IEEE 802.3at compliant (PoE/PoE+).
- Short circuit protection.
NetWaySP4P2:
-
Four (4) 56VDC power-limited outputs up to 60W max. full power per port.
Total power: 240W. -
Short circuit protection.
Fiber Port: -
Four (4) Gigabit SFP ports.
-
Use with SFP module 1000Base-X (1Gb), compliant to Class 1 laser product (not included).
Ethernet:
- Four (4) ports to switch.
- Wire type: 4-pair CAT5e and higher.
- Connectivity: RJ45, auto-crossover.
- Speed: 10/100/1000Mbps.
- Distance: up to 100m.
Environmental:
- Refer to Environmental Conditions on page 6.
Battery Backup:
- Built-in battery charger (optional rack mount battery enclosure – RE2).
- Automatic switchover to stand-by battery when AC fails.
Compatible PoE Hardened Switches and Accessories:
NetWaySP3WPN: | 3-port PoE Hardened Switch with (1) SFP port. |
---|---|
NetWay4EWPN: | 4-port PoE Hardened Switch with (1) SFP port. |
NetWaySP4WPN: | 4-port PoE Hardened Switch with (2) SFP ports. |
NetWaySP8WPN: | 8-port PoE Hardened Switch with (2) SFP ports. |
RE2: | Rack Mount Battery Enclosure 12VDC/7AH batteries |
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. NetWaySP4P/NetWaySP4P2 is not intended to be connected to outside plant leads. These products are for indoor use only and must be installed within the protected premises. NetWaySP4P must be installed in a restricted access area. NetWaySP4P2, if the battery bracket is removed, must be installed in a restricted access area (Fig. 1b, pg. 3). The outputs are of a non-limited power source. For non-limited power sources, additional protective circuitry and/or an appropriate fire enclosure for the products supplied by this device are required.
-
Attach mounting brackets to the unit for rack or wall mount installation (Fig. 4 or 5, pg. 8). Affix rubber pads to the unit for shelf installation (Fig. 6, pg. 8).
-
Secure the unit in a rack or on a wall, or place the unit on a shelf as desired.
-
Note: The following factors should be taken into consideration when installing these rack mount units:
a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
b. Take care to ensure that there is sufficient airflow around the unit and that obstructions do not impede it.
c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.
3. Plug the grounded AC line cord (included) into the IEC 320 connector of the unit (Fig. 2f, pg. 4). Plug the unit into reliable earth grounded socket. When using multiple units, the sum of the individual nameplate ratings should not exceed the supply circuit rating. Do not connect to a receptacle controlled by a switch. -
Connect the structured cable from the ethernet switch/NVR (network video server) to RJ45 jack marked [Ethernet 1-4] (Fig. 2e, pg. 4).
Note: All cabling and wire must be UL Listed and/or Recognized wire suitable for their application. -
Connect Composite (Powered) Fiber cable: fiber portion to port marked [SFP 1-4], copper portion connects to output marked [OUT 56VDC, 1-4] (Fig. 2b & 2d, pg. 4).
-
Connect opposite end of Composite (Powered) Fiber cable: fiber portion to SFP port on NetWay Spectrum Hardened Switch, copper portion connects to the power input of NetWay Spectrum Hardened Switch, carefully observing the correct polarity (Refer to NetWaySP3WPN/4WPN/8WPN / NetWay4EWPN Installation Guides).
-
When the use of stand-by batteries is required, they must be sealed lead acid or gel type. Use 14 AWG or larger for all power connections. Connect four (4) 12VDC batteries in series to terminals marked [+ BAT –] (Fig. 2h, pg. 4).
Note: When batteries are not used, a loss of AC will result in a loss of output voltage.
Recommended Altronix SFP Modules:
Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber
transceiver modules and are readily usable with all Altronix Spectrum fiber
optic equipment for 1Gb transmission rates.
P1MM For use with Multi-Mode Fiber for distances up to 550m.
P1SM10 For use with Single-Mode Fiber for distances up to 10km.
P1AB2K For use with Single Strand Single-Mode Fiber for distances up to
2km.
P1GCE For use with CAT5e or better for distances up to 100m.
2a LED indicates AC Power is present.
2b 1Gb SFP port.
2c LED indicates fiber link.
2d 120W max output
2e RJ45 connects to switch
2f IEC 320 Connector: 115/230VAC (grounded line cord included).
2g Built-in battery charger: Charges stand-by batteries for applications
requiring backup. (Optional rack mount battery enclosure available – RE2)
Typical Application
Technical Specifications
Parameter | Description |
---|---|
Number of Ports | Four (4) Gigabit SFP Ports. Four (4) ports 10/100/1000Mbps. |
Power Outputs | NetWaySP4P: Four (4) 56VDC non power-limited outputs 120W max. |
NetWaySP4P2: Four (4) 56VDC power-limited outputs @ 60W each.
Input power requirements| 115VAC, 60Hz, 3.25A or 230VAC, 50/60Hz, 2.0A.
Environmental Conditions| Operating Ambient Temperature (120W): – 40ºC
to 50ºC (– 40ºF to 122ºF) Relative Humidity: 85%, +/– 5%
Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF). Operating Altitude: –
304.8 to 2,000m.
Regulatory Compliance| UL/cUL Listed for Information Technology
Equipment (UL 60950-1).
**** European Conformity.
Weights (approx.)| Product: 3.8 lbs. (1.7kg) | Shipping: 6.0 lbs. (2.7kg)
** The lightning flash with an arrowhead symbol within an equilateral
triangle is intended to alert the user to the presence of an insulated
DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient
magnitude to constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
CAUTION:** To reduce the risk of electric shock do not open the enclosure.
There are no user-serviceable parts inside. Refer servicing to qualified
service personnel.
Mounting Options
Rack Mount Installation
- Remove and discard factory-installed screws from both sides of the rack chassis (Fig. 4a).
- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 4b).
- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 4c). Fig. 4
Wall Mount Installation
- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 5a).
- Place the unit at the desired location and secure with #6 size screws or larger (not included) (Fig. 5b).
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
Shelf Installation
- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit
- Place the unit in the desired location.
Altronix is not responsible for any typographical errors.
Mounting Hardware (Included):
| Two (2) mounting brackets
---|---
| Six (6) flat head screwsfor mounting brackets.
| Four (4) rubber pads.
140 58th Street, Brooklyn, New York 11220 USA
phone: 718-567-8181
fax: 718-567-9056
website: www.altronix.com
e-mail: info@altronix.com
Lifetime Warranty
NetWaySP4P / NetWaySP4P2 Installation Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>