AcuityBrands

AcuityBrands logo INSTALLATION INSTRUCTIONS
CPX LED Flat Panel Light Fixture
*Model Number
MODELS:
CPX 2X4 40L 40K 120 NODIMAcuityBrands CPX 2X4 40L 40K 120 NODIM CPX LED
Flat Panel Light Fixture

CPX 2X4 40L 40K 120 NODIM CPX LED Flat Panel Light Fixture

*SAVE THESE INSTRUCTIONS
Protect yourself. Before installing, read these instructions carefully and save them for future reference.
Date Installed:__
TOOLS REQUIRED FOR INSTALLATION

  • Safety glasses
  • Protective Gloves
  • Phillips screwdriver
  • Pencil
  • Hammer
  • Pliers
  • Ruler
  • Wire Strippers
  • Flat blade screwdriver

LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING RISK OF ELECTRIC SHOCK
✓ Disconnect or turn off power before installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire label information.
✓ Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
✓ All wiring connections should be capped with UL approved recognized wire connectors.
**WARNING RISK OF BURN
✓ Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF INJURY
✓ Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
✓ Avoid direct eye exposure to the light source while it is on.
CAUTION RISK OF FIRE
✓ Keep combustible and other materials that can burn, away from lamp/lens.
✓ Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION:** RISK OF PRODUCT DAMAGE
✓ Never connect components under load.
✓ Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
✓ Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly off a switched circuit.
✓ Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
✓ Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
✓ Only use fixture in its intended location.
✓ LED products are Polarity Sensitive. Ensure proper Polarity before installation.
✓ Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
✓ Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
✓ Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
✓ Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
✓ Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
✓ Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands| Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts| Indoor Lighting
Aculux
Gotham
Indy
Juno
Mark Architectural Lighting Peerless
Renaissance Lighting Winona Lighting| Outdoor Lighting American Electric Lighting
Antique Street Lamps Hydrel
Tersen| Controls
DARK TO LIGHT LC&D
ROAM
Sensor Switch Synergy| Daylighting
SunOptics
---|---|---|---|---|---

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

T-BAR CEILING GRID INSTALLATION INSTRUCTIONS

Note: Turn off power at circuit breaker box!
Install fixture in T-bar ceiling opening.AcuityBrands CPX 2X4 40L 40K 120
NODIM CPX LED Flat Panel Light Fixture - fig 2From above the ceiling, secure luminaire to T-bar grid by bending the built-in T-bar clips in all 4 corners of lumiaire.
Following local codes, attach the luminaire to the building structure using proper hanger wire to support the luminaire in at least two opposite corners. Use the holes provided in the T-bar clips.AcuityBrands CPX 2X4 40L 40K 120
NODIM CPX LED Flat Panel Light Fixture - fig 3From above the ceiling, take out screw and remove the junction box cover and locate the driver supply wires (1 black, 1 white, 1 green/ground).
Remove one knockeout in access plate and attach building supply conduit. With the power turned off, make electrical connections according to local codes. Secure junction box cover back into luminaire with screw. Turn ON power at circuit breaker and test successful installation.AcuityBrands CPX 2X4 40L
40K 120 NODIM CPX LED Flat Panel Light Fixture - fig 5

AcuityBrands logo 1ACUITY BRANDS LIGHTING, INC.
ONE LITHONIA WAY, CONYERS, GA 30012
www.AcuityBrands.com
1-800-705-SERV (7378)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AcuityBrands User Manuals

Related Manuals