INSTALLATION INSTRUCTIONS
CPX LED Flat Panel Light Fixture
*Model Number
MODELS:
CPX 1X4 ALO7 SWW7
CPX 2X2 ALO7 SWW7
CPX 2X4 ALO8 SWW7
CPX 2X2 ALO7 SWW7 A12
CPX 2X4 ALO8 SWW7 A12
CPX Series LED Flat Panel Light Fixture
5-YEAR LIMITED PRODUCT WARRANTY
Visit www.acuitybrands.com to view the terms
and conditions of your Acuity Brands Lighting, Inc. limited warranty.
*SAVE THESE INSTRUCTIONS
Protect yourself. Before installing, read these instructions carefully and
save them for future reference.
Date Installed:__
TOOLS REQUIRED FOR INSTALLATION
- Safety glasses
- Protective Gloves
- Phillips screwdriver
- Pencil
- Hammer
- Pliers
- Ruler
- Wire Strippers
- Flat blade screwdriver
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
✓ Disconnect or turn off power before installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire
label information.
✓ Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
✓ All wiring connections should be capped with UL approved recognized wire
connectors.
**WARNING RISK OF BURN
✓ Allow lamp/fixture to cool before handling. Do not touch enclosure or
light source.
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/methods, replacement and
recycling.
****CAUTION RISK OF INJURY
✓ Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
✓ Avoid direct eye exposure to the light source while it is on.
CAUTION RISK OF FIRE
✓ Keep combustible and other materials that can burn, away from lamp/lens.
✓ Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
CAUTION:** RISK OF PRODUCT DAMAGE 1
✓ Never connect components under load.
✓ Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
✓ Controls for dimming, auto-sensing, or remote control of a luminaire that
are not factory-wired to the luminaire must be checked for compatibility with
the luminaire prior to installation. LED fixtures must be powered directly off
a switched circuit.
✓ Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insulation, foam, or other material that will
prevent convection or conduction cooling.
✓ Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
✓ Only use fixture in its intended location.
✓ LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
✓ Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal
grounding equipment must be worn during all installation or servicing of the
unit.
✓ Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance.
✓ Some components inside the fixture may not be serviceable. In the unlikely
event your unit may require service, stop using the unit immediately and
contact an ABL representative for assistance.
✓ Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
✓ Always ensure that the electrical distribution system is up to NEC (and any
applicable local code) requirements.
✓ Verify that power distribution system has proper grounding. Lack of proper
earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions
under Delivery. Lithonia Outdoor will always use Part 15. All luminaires that
contain electronic devices that generate frequencies above 9kHz from any
component within the luminaire comply with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may not cause
harmful interference (2) This device must accept any interference received,
including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem, move the device away from the luminaire or
plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands| Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts| Indoor Lighting
Aculux
Gotham
Indy
Juno
Mark Architectural Lighting Peerless
Renaissance Lighting Winona Lighting| Outdoor Lighting American Electric
Lighting
Antique Street Lamps Hydrel
Tersen| Controls
DARK TO LIGHT LC&D
ROAM
Sensor Switch Synergy| Daylighting
SunOptics
---|---|---|---|---|---
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
T-BAR CEILING GRID INSTALLATION INSTRUCTIONS
Note: Turn off power at circuit breaker box!
Use switch on junction box to select appropriate light color (CCT) and light
output (Lumens). 40K at High Lumen is factory default setting.
Install fixture in T-bar ceiling opening. From above the ceiling, secure
luminaire to T-bar grid by bending the built-in T-bar clips in all 4 corners
of lumiaire.Following local codes, attach the
luminaire to the building structure using proper hanger wire to support the
luminaire in at least two opposite corners. Use the holes provided in the
T-bar clips.From above the ceiling, take out screw
and remove the junction box cover and locate the driver supply wires (1 black,
1 white, 1 green/ground).
Optional dimming: for 0-10V dimming only: Purple wire is 0-10V(+), Gray / Pink
wire is 0-10V(-) With the power turned off, make electrical connections
according to local codes. Secure junction box cover back into luminaire with
screw. Turn ON power at circuit breaker
and test successful installation. Contractor
Resources
Check out helpful programs, tools, installation videos and more!
ACUITY BRANDS LIGHTING, INC.
ONE LITHONIA WAY, CONYERS, GA 30012
www.AcuityBrands.com
1-800-705-SERV (7378)
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>