motorline MC62 Control Unit User Manual
- June 9, 2024
- motorline
Table of Contents
USER’S AND INSTALLER’S MANUAL
SAFETY INSTRUCTIONS
ATTENTION:
** This product is certified in accordance with European Community (EC)
safety standards.
` RoHS` This product complies with Directive 2011/65/EU of the European
Parliament and of the Council, of 8 June 2011, on the restriction of the use
of certain hazardous substances in electrical and electronic equipment and
with Delegated
Directive (EU) 2015/863 from Commission.
(Applicable in countries with recycling systems).
** This marking on the product or literature indicates that the product and
electronic accessories (eg. Charger, USB cable, electronic material, controls,
etc.) should not be disposed of as other household waste at the end of its
useful life. To avoid possible harm to the environment or human health
resulting from the uncontrolled disposal of waste, separate these items from
other types of waste and recycle them responsibly to promote the sustainable
reuse of material resources. Home users should contact the dealer where they
purchased this product or the National Environment Agency for details on where
and how they can take these items for environmentally safe recycling. Business
users should contact their vendor and check the terms and conditions of the
purchase agreement. This product and its electronic accessories should not be
mixed with other commercial waste.
This marking indicates that the product and electronic accessories (eg.
charger, USB cable, electronic material, controls, etc.) are susceptible to
electric shock by direct or indirect contact with electricity. Be cautious
when handling the product and observe all safety procedures in this manual.
GENERAL WARNINGS
- This manual contains very important safety and usage information. very important. Read all instructions carefully before beginning the installation/usage procedures and keep this manual in a safe place that it can be consulted whenever necessary.
- This product is intended for use only as described in this manual. Any other enforcement or operation that is not mentioned is expressly prohibited, as it may damage the product and put people at risk causing serious injuries.
- This manual is intended firstly for specialized technicians, and does not invalidate the user’s responsibility to read the “User Norms” section in order to ensure the correct functioning of the product.
- The installation and repair of this product may be done by qualified and specialized technicians, to assure every procedure are carried out in accordance with applicable rules and norms. Nonprofessional and inexperienced users are expressly prohibited of taking any action, unless explicitly requested by specialized technicians to do so.
- Installations must be frequently inspected for unbalance and the wear signals of the cables, springs, hinges, wheels, supports and other mechanical assembly parts.
- Do not use the product if it is necessary repair or adjustment is required.
- When performing maintenance, cleaning and replacement of parts, the product must be disconnected from power supply. Also including any operation that requires opening the product cover.
- The use, cleaning and maintenance of this product may be carried out by any persons aged eight years old and over and persons whose physical, sensorial or mental capacities are lower, or by persons without any knowledge of the product, provided that these are supervision and instructions given by persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved.
- Children shouldn’t play with the product or opening devices to avoid the motorized door or gate from being triggered involuntarily.
WARNINGS FOR TECHNICIANS
- Before beginning the installation procedures, make sure that you have all the devices and materials necessary to complete the installation of the product.
- You should note your Protection Index (IP) and operating temperature to ensure that is suitable for the installation site.
- Provide the manual of the product to the user and let them know how to handle it in an emergency.
- If the automatism is installed on a gate with a pedestrian door, a door locking mechanism must be installed while the gate is in motion.
- Do not install the product “upside down” or supported by elements do not support its weight. If necessary, add brackets at strategic points to ensure the safety of the automatism.
- Do not install the product in explosive site.
- Safety devices must protect the possible crushing, cutting, transport and danger areas of the motorized door or gate.
- Verify that the elements to be automated (gates, door, windows, blinds, etc.) are in perfect function, aligned and level. Also verify if the necessary mechanical stops are in the appropriate places.
- The central must be installed on a safe place of any fluid (rain, moisture, etc.), dust and pests.
- You must route the various electrical cables through protective tubes, to protect them against mechanical exertions, essentially on the power supply cable. Please note that all the cables must enter the central from the bottom.
- If the automatism is to be installed at a height of more than 2,5m from the ground or other level of access, the minimum safety
- and health requirements for the use of work equipment workers at the work of Directive 2009/104/CE of European Parliament and of the Council of 16 September 2009.
- Attach the permanent label for the manual release as close as possible to the release mechanism.
- Disconnect means, such as a switch or circuit breaker on the electrical panel, must be provided on the product’s fixed power supply leads in accordance with the installation rules.
- If the product to be installed requires power supply of 230Vac or 110Vac, ensure that connection is to an electrical panel with ground connection.
- The product is only powered by low voltage satefy with central (only at 24V motors)
WARNINGS FOR USERS
- Keep this manual in a safe place to be consulted whenever necessary.
- If the product has contact with fluids without being prepared, it must immediately disconnect from the power supply to avoid short circuits, and consult a specialized technician.
- Ensure that technician has provided you the product manual and informed you how to handle the product in an emergency.
- If the system requires any repair or modification, unlock the automatism, turn off the power and do not use it until all safety conditions have been met.
- In the event of tripping of circuits breakers of fuse failure, locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse. If the malfunction is not repairable by consult this manual, contact a technician.
- Keep the operation area of the motorized gate free while the gate in in motion, and do not create strength to the gate movement.
- Do not perform any operation on mechanical elements or hinges if the product is in motion.
RESPONSABILITY
- Supplier disclaims any liability if:
- Product failure or deformation result from improper installation use or maintenance!
- Safety norms are not followed in the installation, use and maintenance of the product.
- Instructions in this manual are not followed.
- Damaged is caused by unauthorized modifications
- In these cases, the warranty is voided.
MOTORLINE ELECTROCELOS SA.
Travessa do Sobreiro, nº29 4755-474 Rio Côvo (Santa Eugénia)
Barcelos, Portugal
SYMBOLS LEGEND:
**** | • Important safety notices |
---|---|
• Useful information | |
• Programming information | |
• Potentiometer information | |
• Connectors information | |
• Buttons information |
CONTROL BOARD
CHARACTERISTICS
The MC62 is a control board with built-in radio control system, developed
for the automation of 24V swing gates.
• Power Supply | 20/24V AC |
---|---|
• Flashing light’s output | 24VDC 4W Max. |
• RGB Flashing light’s output | 24Vdc 100mA Max. |
• Motor’s output | 24Vdc 2 x 120W Max. |
• Auxiliary accessories output | 24V DC 8 W Max. |
• Security and BT remote controls | 24V DC |
• Working temperature | -25°C to + 55°C |
• Incorporated Radio Receptor | 433,92 Mhz |
• OP remote controls | 12bits or Rolling Code |
• Maximum Memory Capacity | 100 (full opening) – 100 (pedestrian opening) |
• Control Board Dimensions | 150×100 mm |
CONNECTORS
VAC| 01 • Power Supply Input – 20/24Vac 120W
02 • Power Supply Input – 20/24Vac 120W
---|---
V+| 01 • 24Vdc Input for Emergency Battery
02 • COM Input (Solar Panel or Emergency Battery)
03 • 24Vdc Input for Solar Panel
LOCK| 01 • Flashing light’s Output – 24Vdc 4W
02 • Flashing light’s Output – 0V
MOT2| 01 • Motor 1 Output – 24Vdc 120W
02 • Motor 1 Output – 24Vdc 120W
MOT1| 01 • Motor 2 Output – 24Vdc 120W
02 • Motor 2 Output – 24Vdc 120W
LAMP| 01 • ElectricLock Output – 12/24Vdc 12W
02 • ElectricLock Output – 0V
BATT| 01 • Accessories Output – 24Vdc 8W
02 • Accessories Output – 0V
LO| 01 • NO input for complete maneuver button
02 • Common
LS| 01 • NO input for pedestrian maneuver button
02 • Common
LE| 01 • NC input for external photocells
02 • Common
LA| 01 • NC input for internal photocells
02 • Common
LC1| 01 • NC input for anti-crushing photocells
02 • Common
LC2| 01 • NC input for anti-crushing photocells
02 • Common
ANT| 01 • Antenna
02 • GND
RECOMMENDATIONS PRIOR TO PROGRAMMING
LEDs
LS • LED On when pedestrian opening is active.
LO • LED On when full opening is active.
LE • LED on when the photocell is active or the LE circuit is closed.
LA • LED on when the photocell is active or the LA circuit is closed.
LC1 • LED on when the circuit LC1 is closed (anti-crushing photocells).
LC2 • LED on when the circuit LC2 is closed (anti-crushing photocells).
INSTALLATION
BASE INSTALLATION PROCESS
The installation process assumes that the gate already has mechanical or
electrical limit switches installed. For more information read the motor’s
manual
01 • Connect all accessories according to the connections diagram (page 22A).
02 • Connect the control board to a 20V power supply
03 • Check if the gate movement is the same as shown on the display:
|
---|---
CLOSE| OPEN
If the display does not match the movement of the gate, switch off the control
board from power supply and change the wires of Motor1 (0 and 0) and Motor2 (0
and 0).
04 • Make a course programming – menu P0 (page 9A).
05 • If necessary, adjust the deceleration time of the gate at opening and
closing – menu P1 (page 10A).
06 • Adjust the gate force and sensitivity – menu P2 (page 10B).
07 • Re-program the course – menu P0 (page 9A ).
08 • Enable or disable the use of Photocells in menu P5 and P6 (page 12B and
13A ).
09 • Program a remote control (page 7A).
The control board is now fully configured!
Check the pages of the menu programming if you want to configure other
features of the Control board.
After completing the entire installation of the electrical panel, it is
mandatory to seal with silicone all openings in the box (accesses, cable
passages and slots) to prevent the entry of moisture and insects that could
compromise the normal functioning of the electrical components.
REMOTE CONTROLS
Remote controls programming for total opening.
Remote controls programming for pedestrian opening.
PROGRAMMING REMOTE CONTROLS
- Press the cmd button for 1 sec.
- Select the function where you want to program the remote control (SU or SP) use ↓↑.
- Press cmd once to confirm the function (SU or SP).
- The first free position appears.
- Press the remote control button you want to program. The display will blink and move to the next free location.
ERASE REMOTE CONTROLS
- Press the cmd button for 1 sec.
- Select the function (SU or SP) use↓↑.
- Press cmd once to confirm the function (SU or SP).
- Use ↓↑ to select the remote control location you want to delete.
- Press cmd for 3 sec and the location will be empty.
The display will blink and the position will be free.
ERASE ALL THE REMOTE CONTROL
- Press the cmd button for 5 sec.
- The display will show dL, confirming that all remote controls have been erased.
Whenever you store or delete a remote control, the display will flash and show
the next position. You can add or delete remote control, without needing back
to point01.
If you do not press any button for 10 sec. the control board will return to
standby
We can only go into programming with the gate electrically stumbled.
The functions of the control board are divided into 2 areas:
- Main Menus “P”
- Extra Menus “E”
P MENU
- To access the P menu press the MENU buttonfor 2 sec.
- Use ↓↑ to navigate through the menus.
- Press MENU when you want to confirm access to a menu.
- Press ↓↑ simultaneously to exit programming.
- To access the E menu press the MENU button for 10 sec.
- Use ↓↑ to navigate through the menus
- Press MENU when you want to confirm access to a menu.
- Press ↓↑simultaneously to exit programming.
FUNCTIONS MENU “P”
FUNCTIONS MENU “E”
PROGRAMMING “P”
COURSE PROGRAMMING
Course Manual Programming
This menu allows you to manually set the course of the leaf/leaves.
Default value (NA)
Number of Motors
Allows you to define the number of motors connect to the control board
Default value (02)
DIRECTION OF
DISPLAY ROTATION| COURSE PROGRAMMING OF TWO MOTORS
---|---
| Normal rotation – leaf 1 starts opening (normal speed)
Slow rotation – leaf 1 goes into opening slowdown (slowdown speed)
| Normal rotation – leaf 1 stops and leaf 2 starts opening (normal speed)
Slow rotation – leaf 2 goes into opening slowdown (slowdown speed)
| Normal rotation – leaf 2 stops and starts closing (normal speed)
Slow rotation – leaf 2 goes into closing speed (slowdown speed)
| Normal rotation – leaf 2 stops and leaf 1 starts opening (normal speed)
Slow rotation – leaf 1 goes into closing slowdown (slowdown speed)
COURSE PROGRAMMING OF ONE MOTOR (PEDESTRIAN)
| Normal rotation – leaf starts opening (normal speed)
Slow rotation – the leaf goes into opening slowdown (slowdown speed)
| Normal rotation – the leaf stops and starts closing (normal speed)
| Slow rotation – the leaf goes into closing slowdown (slowdown speed)
Manual programming:
01 • Press MENU for 2 sec. until appears.
02 • Press MENU once until appears.
03 • Press MENU (or remote control) to start programming the opening time.2
MOTORS ( =)
04 • Press MENU to start slowdown.
05 • Press MENU to stop leaf 1 (leaf 2 starts opening automatically).
06 • Press MENU to start slowdown.
07 • Press MENU to finish opening and start closing leaf 2.
08 • Press MENU to start slowdown.
09 • Press MENU to stop leaf 2 (leaf 1 starts closing automatically).
10 • Press MENU to start slowdown.
11 • Press MENU to finish closing leaf 1.
Display will show signaling that leaves are closed.
1 MOTOR (PEDESTRIAN) ( = )
04 • Press MENU to start the opening slowdown of the leaf.
05 • Press MENU to stop the leaf and start programming the closing time.
06 • Press MENU to start the closing slowdown of the leaf.
07 • Press MENU once to display , leaf 1 stops.
08 • Use UP and DW to display to exit programming mode.
09 • Use UP and DW to stay in Standby.
You can use the remote instead of the MENU button.
Whenever a leaf touches a stop, wait 1 second before clicking on the MENU.
DECELERATION TIME ADJUSTMENT
This menu allows to set the deceleration time of each leaf at opening and
closing.
|
---|---
Slowing down on opening leaf 1 It allows to define the time that the gate will
act with slowdown in the opening.| Slowing down on closing leaf 1 It allows to
define the time that the gate will act with slowdown in the closing.
|
Slowing down on opening leaf 2 It allows to define the time that the gate will
act with slowdown in the opening.| Slowing down on closing leaf 2 It allows to
define the time that the gate will act with slowdown in the closing.
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press Menu will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
- Press MENU again.
- Use UP and DW to display to exit programming mode.
- Use UP and DW to stay in Standby.
FORCE AND SENSITIVITY ADJUSTMENT
A very low value in this parameter may cause the motor to not have enough
torque to move the gate and the effort error occurs (1or 2).
|
---|---
Force adjustment
Allows you to set the force that is injected into the motor when it moves at
normal speed.| Sensitivity adjustment
Allows to adjust the sensitivity of the motor in the presence of obstacles.
The higher the sensitivity, the less effort it will take to detect
any obstacle and reverse direction.
|
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press Menu will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
PEDESTRIAN COURSE TIME
The pedestrian mode allows the gate to be opened for the passage of people,
without it needing to open in its entirety.
In this function you can schedule the time you want the gate to open.
For pedestrian mode to work, it is necessary that the minimum work is 1
second, and 0 disables the pedestrian.
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press MENU. The factory set time appears.
- Use UP and DW to change the value.
- Press MENU to save the new value.
PAUSE TIME AND GATES DELAY
| | |
---|---|---|---
Closing time adjustment
Allows adjustment of the pause time for
automatic closing.| Pedestrian closing pause time adjustment
Allows you to set the pause time at the pedestrian opening.| Gate delay in
closing
Allows you to set the delay time for closing leaf 1 relative to leaf 2.|
Gate delay in opening
Allows you to set the delay time for
opening leaf 1 relative to leaf 2.
| | |
When the values are at zero, there is no automatic closing.
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press Menu will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
PHOTOCELLS 1 PROGRAMMING
Allows you to program le security behavior (photocell 1).
| | |
---|---|---|---
00 (disables photocells) 01 (activates photocells) Enable or disable security
entry.| 00 (opening photocells) 01 (closing photocells) This menu can only be
changed when the LE menu is active. Allows you to define whether this security
will act when opening or
closing the gate.| 00 (the gate is reversed)
01 (gate stops and resumes 5 sec after security is disabled)02 (gate reverses
for 2 sec. and stop) Allows you to set the behavior that the gate
will have when this security is
activated.| 00 (disables photocells) 01 (activates
photocells) Allows you to activate or deactivate the LC1 input (anti-crushing
photocell 1)
Default value (00)| Default value (01)| Default value (00)| Default value (00)
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press Menu will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
PHOTOCELLS 2 PROGRAMMING
Allows to program LA security behavior (photocell 2).
| | |
---|---|---|---
00 (disables photocells)
01 (activates photocells)
Enable or disable security entry.| 00 (opening photocells) 01 (closing
photocells) This menu can only be changed when the LA menu is active. Allows
you to define whether this security will act on the opening or closing of the
gate.| 00 (the gate is reversed) 01 (gate stops and resumes 5 sec after
security is disabled) 02 (gate reverses for 2 sec. and stop) 03 (the gate
reverses at the closing, tops and reverses 2 sec. at the pening) Allows to
set the behavior hat the gate will have when this security is activated.| 00
(disables photocells) 01 (activates photocells)
Allows you to activate or disable the LC input (anti-crushing
photocell 2)
Default value (00)| Default value (00)| Default value (01)| Default value (00)
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press MENU will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
OPERATING LOGIC
This menu allows to set the operating logic of the automation
| |
---|---|---
Automatic Mode Whenever there is an order the
movement is reversed.| Step by step mode
1st impulse – OPEN
2nd impulse – STOP
3rd impulse – CLOSE
4th impulse – STOP
If it is fully open and timed, it closes.| Condominium Mode
Does not respond to orders during opening and pause time.
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press Menu will appear .
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
FLASHING LAMP
This menu allows to set the operation mode of the flashing lamp (LAMP).
| |
---|---|---
Intermittent (opening and closing) During the opening/closing movement of
the gate, the flashing lamp will work intermittently| In the opening and
closing movement, the flashing lamp is permanently on.| Courtesy light
The light will stay on for the time set in the E2 menu.
Default value (00)
- Press MENU for 2 sec. until it appears .
- Use UP until appears .
- Press Menu will appear .
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
REMOTE PROGRAMMING
|
---|---
Distance PGM OFF| Distance PGM ON
This menu allows to enable or disable the programming of new remote controls without directly accessing the control board, using a previously stored remote controls (memorize remote controls page 5B).
- Press MENU for 2 sec. until it appears.
- Use UP until appears.
- Press Menu will appear.
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
Remote Programming Operation (PGM ON):
- Press the buttons indicated in the image simultaneously for 10 seconds and the flashing lamp will flash (the 1st free position appears in the display).
Each time you store 1 remote control, the control board will exit remote programming. If you want to memorize more remote controls, you will always have to repeat the process of pressing the remote control buttons simultaneously for 10 seconds for each new remote control.
PROGRAMMING “E”
HUMAN PRESENCE
00 (disables human presence) Whenever an order is sent to the LO input and
the motor performs a complete maneuver. Human presence 01 (active human
presence) The motor only works if you keep the LS button pressed.
With the human presence active the RF remote controls do not work.
00 (disables pushbutton mode) 01 (active pushbutton mode)
| LS| LO
---|---|---
01
ON| Full closing| Full opening
00
OFF| Pedestrian maneuvers| Total maneuvers
Allows you to define how the LS input works. 00 (disables input to emergency
stop device) 01 (input for emergency stop devices)
If you have the LS submenu in 01 (active) and the PL submenu in 01 (active),
the error appears .
Default value (00)
- Press MENU for 10 sec. until it appears .
- Press MENU until it appears . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
SOFT START
00 function disabled
01 function activated
This menu allows activate/disable soft start.
With the soft start function activated, at each start of movement, the control
board will control the start of the motor, gradually increasing in the first
second of operation.
Default value (00)
- Press MENU for 10 sec. until it appears .
- Use UP until appear
**E1.**
- Press Menu will appear .
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
COURTESY LIGHT TIME
Allows to adjust the courtesy light time. The courtesy light is activated
for the set time when the gate is in the closed, open and standing position.
The E2 menu will only be available in the case if the courtesy light function
is activated in the P8 menu option 2 (see page 11B)
Default value (00)
- Press MENU for 10 sec. until it appears .
- Use UP until appears .
- Press Menu will appear .
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
FOLLOW ME
00 function disabled
01 function activated after opening 02 function activated on opening
Allows you to activate the Follow me option. With this option activated, the
control board, when in the open position or in opening, gives a closing order
of 5 sec. after the safety device detects the passage of an object / user.
Default value (00)
- Press MENU for 10 sec. until it appears .
- Use UP until appears .
- Press MENU. The factory set time appears.
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
COURSE TIME ADJUSTMENT
It allows to adjust the working time for the opening and closing courses of
the two leafs.
Leaf 1
| | |
---|---|---|---
Opening course time (minutes)| Opening course time (seconds)| Closing course
time (minutes)| Closing course time (seconds)
Default value (00)| Default value (10)| Default value (00)| Default value (10)
Leaf 2
| | |
Opening course time (minutes)| Opening course time (seconds)| Closing course
time (minutes)| Closing course time (seconds)
Default value (00)| Default value (10)| Default value (00)| Default value (10)
- Press MENU for 10 sec. until it appears .
- Use UP until appears .
- Press MENU will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
BRAKE/LOCK/PUSH
Allows to program gate behavior
| | | |
---|---|---|---|---
00 (disables electronic
brake) 01 (activates electronic brake) Allows you to activate the electronic
brake.| 00 (active lock on opening 2 sec.)
01 (activates lock whenever in motion) Allows you to select the
lock’s operating mode.
The default value is 0 (2 second pulse on opening). Note: If you select
option 2, you must take into account the maximum current value provided by the
control board| 00 (disable opening push)
01 (active opening push)
Allows you to activate the
opening stroke (ram).| 00 (disables closing push)
01 (active closing push)
Allows you to activate the
closing push.| 00 (disables motor lock on the closing) 01 (activates motor
lock on the closing) Allows you to activate the locking of the motors in the
closed position.
Serves mainly for hydraulic motors.
Default value (00)| Default value (00)| Default value (00)| Default value
(00)| Default value (00)
- Press MENU for 10 sec. until it appears .
- Use UP until appears .
- Press MENU will appear . Use UP or DW to navigate the parameters.
- Press MENU to edit the chosen parameter value.
- The factory set time appears. Use UP and DW to change the value.
- Press MENU to save the new value.
DECELERATION SPEED
This menu allows you to adjust the deceleration speed.
The higher the level, the faster the deceleration.
- Press MENU for 10 sec. until it appears .
- Use UP until appears .
- Press MENU will appear .
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
MANUEVERS COUNTER
This menu allows you to view the number of maneuvers were performed by the
control board. (complete maneuver means opening and closing).
Resetting the control board does not clear the maneuver count.
Example: 13456 maneuvers
01- Hundred thousand / 34- Thousands / 56- Dozens
- Press MENU for 10 seconds.
- E0 appears. Press UP until appears E7.
- Press MENU.
- The maneuvers count is displayed in the following order (example: 130 371)05
- E8 appears.
RESET – RESET FACTORY VALUES
When resetting, all factory values will be reset.
The memorized remote controls and the maneuver counter will always have the
memorized data.
- Press MENU for 10 sec. until it appears .
- Use UP until appears ****.
- Press MENU will appear .
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
RGB OUTPUT
|
---|---
Co ntinuous light| Flashing light
Default value (00)
- Press MENU for 10 sec. until it appears.
- Use UP until appears.
- Press MENU will appear.
- Press MENU to edit the value.
- Use UP and DW to change the value.
- Press MENU to save the new value.
DISPLAY
MENU | DESCRIPTION | MENU | DESCRIPTION |
---|---|---|---|
In the still position, fully open | All commands erased | ||
In the still position, intermediate position | Command triggered from the |
indicated position
| In the still position, fully closed| | Obstructed photocell
| Full opening button pressed| | Obstructed photocell
****| Pedestrian opening button pressed| | In pause time
| Central to run the opening course| | In time of pedestrian pause
| Central to run the closing course| | Motor overcurrent detection 1
| End of opening course time| | Motor overcurrent detection 2
| End of opening course time| | Emergency stop circuit open. Check that the
security is turned on correctly.
| Full memory| |
TROUBLESHOOTING
Anomaly| Procedure| Behavior| Procedure II|
Discovering the origin of the problem
---|---|---|---|---
• Motor doesn’t work.
| • Make sure you have power supply 230/110V connected to control board and if it is working properly.|
• Still not working.
|
• Consult a qualified technician MOTORLINE.
| 1•Open control board and 3 Disconnect motors from 4• If the motors work, the5 • If the motors don’t work, check if it has 230/110V power control board and test them by problem is on the control board. remove them from installation supply; connecting directly to a 12/24V Pull it out and send it to our site and send to our technical battery in order to find out if MOTORLINE technical services services for diagnosis. 2 • Check input fuses; they have problems. for diagnosis;
• Motor doesn’t move but makes noise.
|
• Unlock motor and move the gate by hand to check for mechanical problems on the movement.
| • Encountered problems?| • Consult a qualified gates technician.| 1 • Check all motion axis and associated motion systems related with the gate and automation (rails, pulleys, bolts, hinges, etc) to find out what is the problem.
• The gate moves easily?
|
• Consult a qualified
MOTORLINE technician.
| 1• If the motors work, the2 • If the motors don’t work, problem is on the control board. remove them from installation Pull it out and send it to our site and send to our MOTORLINE MOTORLINE technical services technical services for diagnosis. for diagnosis;
•Motors open but doesn’t close.
|
• Unlock motor and move the gate by hand to closed osition. Block the motor again and urn off power supply for 5 seconds. econnect it nd send order to open gate using remote control.
|
•Gate opened but didn’t close again.
|
1 • Check if there is any obstacle in front of the hotocells; 2 • Check if any of the control devices (Key Selector, Pushbutton, Video Intercom, etc.) are stucked and sending permanent signal to control board; 3 • Consult a qualified MOTORLINE technician.
| All control boards have LEDs that easily A) SECURITY SYSTEMS B) START SYSTEMS: allow to conclude which devices are with anomalies. All safety devices EDs (DS) in 1•Close with a shunt all safety systems 1 • Disconnect all wires connected to the normal situations remain On. All “START” on the control board (check manual of the START connector (LO and LE). LEDs in normal situations remain Off.ontrol board). If the automated system If LEDs devices are not all On, there is some starts working normally check which device 2 • If the LED turned OFF, try reconnecting security systems malfunction (photocells,is roblematic. one device at a time until you find the safety edges). If “START” LEDs are on, there defective device. is a control device sending permanent signal. 2 • Remove one shunt at a time until you find the malfunction device. NOTE: 3 • Replace it for a functional device and In case procedures described in sections A ) check if the motor works correctly with all and B ) don’t result, remove control board and the other devices. If you find another onesend to our MOTORLINE technical services defective, follow the same steps until you for diagnosis. find all the problems.
•Motor doesn’t make complete course.
|
•Unlock motor and move gate by hand to check for mechanical problems on the gate.
| •Encountered problems?| •Consult an experienced gates expert.| 1•Check all motion axis and associated motion systems related with the gate and automation (rails, pulleys, bolts, hinges, etc) to find out what is the problem.
•The gate moves easily?
|
•Consult a qualified technician MOTORLINE.
| 1 • If the motors don´t work,and closing with appropriate
NOTE:remove them from installation force (consult control board Setting
force of the control board site and send to our MOTORLINE manual).should be
enough to open and technical services for diagnosis. close the gate without
stopping, 3 • If this doesn’t work, remove but should stop and invert with 2 •
If motor work well and move control board and send it toa little effort from a
person. In gate at full force during the MOTORLINE technical services.
case of safety systems failure, the entire course, the problem is gate shall
never cause physical on the control board. Make a damaged to obstacles
(vehicles, new working time programming, people, etc.). giving enough time for
opening
CONNECTIONS SCHEME
C62MC62
v1.7
REV. 11/2022