Safety Guidelines

  1. Follow the installation instructions.

  2. Use the appliance
    • according to its intended use
    • in good condition
    • with due regard to safety and risk of danger.

  3. Note that the appliance is exclusively for use in the applications detailed in these installation instructions (see 2 Technical Data). Any other use will not be considered to comply with requirements and would invalidate the warranty.

  4. Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons.

  5. Immediately rectify any malfunctions which may influence safety.

Technical Data

Media

Medium:| Drinking water
Connections/Sizes
Connection sizes:| Rp 3/4″ (DIN EN 10226)
Pressure values
Max. operating pressure:| 10 bar
Operating temperatures
Operating temperatures: TS131-3/4 A+B
TS131-3/4ZAx| ** 95 °C
x =50 / 100 / 110 °C
Max. ambient temperature:| 70 °C
Specifications**
Heating system capacity:| max. 100 kW
Capacity:| 2800 kg/h water at the pressure drop D p=1 bar (Inlet pressure 5 bar; Outlet pressure 4 bar; 110°C medium temperature) (1 capillary tube)
Mode of operation:| 2 Kp Solid/dual-fuel boilers with integrated water heater or cooling coil in closed heating systems according to EN 12828

Options

For Options visit homecomfort.resideo.com/europe

Assembly

4.1 Installation Guidelines
• The valve and the sensor must be installed carefully to avoid any damage to the capillary tube
• The opening on the blow-out line must be clear and easy to monitor
• Ensure no persons are in danger when blowing off the valve
• A sufficiently dimensioned discharge line must be provided

kVS value: p = 1 bar
3 m3/h: with 2 intact sensor systems (with a media temperature of 110 °C)
2.1 m3/h: with one sensor system (with a media temperature of 110 °C)
CAUTION!
Installation of the thermal discharge safety valve does not replace the diaphragm relief value in the cold water supply line to the water heater.
4.2 Assembly instructions

  1. Install a thermal discharge safety valve according to the installation diagram
    • Flow direction is indicated by an arrow

  2. Push the heat sensor into the immersion pipe up to the stop point and secure with a round screw to stop it being pulled out

Start-up

CAUTION!
On commissioning the heating system, the person preparing the system must check that the thermal discharge safety valve is functioning perfectly.

Maintenance

**** In order to comply with EN 806-5, water fixtures must be inspected and serviced on an annual basis.
As all maintenance work must be carried out by an installation company, it is recommended that a servicing contract should be taken out.
In accordance with EN 806-5, the following measures must be taken:

6.1 Inspection and Maintenance
**** Do not use any cleansers that contain solvents and/or alcohol for cleaning the plastic parts, because this can cause damage to the plastic components – water damage could result.
Detergents must not be allowed to enter the environment or the sewerage system!

  • According to the requirements of EN 12828, the system operator is obliged to have the thermal discharge safety valve checked by a professional at least once a year to ensure its functional readiness.
  1. Check whether water is escaping from the housing
    • if water is escaping, the seals (entire piston guide) must be replaced, or it may be necessary to replace the unit

  2. Operate the check valve and first check whether water is escaping and the valve then closes again
    • if no water is escaping or the valve does not close, the unit may have to be replaced

Disposal

Observe the local requirements regarding correct waste recycling/disposal!

Spare Parts

For Spare Parts visit homecomfort.resideo.com/europe

Manufactured for and on behalf of
Pittway Sàrl, Z.A., La Pièce 4,
1180 Rolle, Switzerland
by its authorised representative
Ademco 1 GmbH
For more information
homecomfort.resideo.com/europe
Ademco 1 GmbH, Hardhofweg 40,
74821 MOSBACH, GERMANY
Phone: +49 6261 810
Fax: +49 6261 81309
© 2020 Resideo Technologies, Inc. All rights reserved.
Subject to change. MU1H-1543GE23 R0420

Documents / Resources

| resideo Braukmann TS131 [pdf] Installation Guide
Braukmann TS131, Braukmann, TS131
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals