resideo R200C-1 Carbon Monoxide Alarm User Guide

June 4, 2024
resideo

resideo-Logo

resideo R200C-1 Carbon Monoxide Alarm

resideo-R200C-1-Carbon-Monoxide-Alarm-Product-Image

Picture Guide

resideo-R200C-1-Carbon-Monoxide-Alarm-02

Introduction

Thank you for purchasing this R200C-1 CO alarm (Carbon Monoxide).

resideo-R200C-1-Carbon-Monoxide-Alarm-03

The symbols above mean that the CO alarm is suitable for use in domestic premises (including static caravan holiday homes), caravans, motor caravans and boats.

NOTE: this manual contains important safety information. Please store it for future reference.

Where to install the CO alarm?

Ideally, a CO alarm should be installed in every room containing a fuel- burning appliance and in a room where the occupant(s) spend most time like the bedroom and study/hobby room. If there is a partition in a room, the apparatus should be located on the same side of the partition as the potential source. Carbon monoxide alarms in rooms with sloped ceilings should be located at the high side of the room.

1- Ceiling mounting / 2- Wall mounting / 3- Bedroom / 4- Study/Hobby room

Installation

Where not to install the CO alarm?

In an enclosed space (for example in a cupboard or behind a curtain).

Where it can be obstructed (for example by furniture).

Directly above a sink.

Next to a door or window.

Next to an extractor fan.

Next to an air vent or other similar ventilation openings.

In an area where the temperature may drop below -10 °C or exceed 40 °C.

Where dirt and dust may block the sensor.

In a damp or humid location.

In the immediate vicinity of a cooking appliance.

If you need to enable the tamper proof locking feature, break off or cut off the small cylinder (1).

Attach (2 ) the wall bracket to the wall or ceiling. Fit the CO alarm onto the wall bracket (3). Press firmly against the wall plate and slide (4) the CO alarm down. The device will be activated.

Activation

Within 5 seconds after installing, the device will be activated.

All indicators will flash, the sounder will beep and the device will enter a warm-up state.

The CO alarm has been activated.

The green POWER light blinks once per second.

After 60 seconds, the green POWER light blinks once every minute.

The CO alarm is working normally.

For deactivation follow the instructions in section 6

Removal

Use a small screwdriver to press on the tamper proof locking tab (5) located at the right edge of the CO alarm. Slide the CO alarm up (6) to remove it from the wall mounting plate. When removed the CO alarm from the wall mounting plate, the CO alarm enters “Deep Sleep” mode and no longer monitors carbon monoxide levels.

Recommended actions when CO alarm warning has been activated

If your CO alarm is in ALARM, keep calm, and carry out the following actions in the following order:
Open all doors and windows to increase the rate of ventilation.
Stop using all fuel-burning appliances and turn them off where possible.
If the CO alarm continues, then evacuate the premises. Leave the doors and windows open, and only re-enter the building when the alarm has stopped.
Get medical help for anyone suffering the effects of Carbon Monoxide poisoning, such as headache or nausea, and advise that Carbon Monoxide inhalation is suspected.
Telephone the gas or other fuel supplier on their emergency number, so that the source of carbon monoxide emissions can be identified and corrected.
Do not use the fuel-burning appliances again until they have been checked and cleared for use by a competent person according to national regulations.

Note: There may be another source of carbon monoxide emission apart from fuel-burning appliances, for example a large amount of tobacco smoke, town gas or emission from a smouldering fire. Do not use any combustion appliances until they have been checked by a qualified person.

Visual & acoustic signals

LED| POWER
Green
| 8. ALARM
Red
| FAULT
Yellow
| BEEP
Sounder
| ****
---|---|---|---|---|---
Normal operation| 1 x every minute| off| off| off| Normal operation.

No CO detection.

Test| 1 x| 4 flashes x 2 times| off| 4 beeps x 2 times| The entire device cover is its TEST / SILENCE button.

Press cover TEST/SILENCE button 3 sec.

CO alarm warning| off| 4 x Continuously| off| Continuously| CO alarm warning.
Alarm silence| off| 4 x every minute| off| Muted| CO alarm warning

MUTED ALARM SOUND 10 MINUTES

Alarm memory| off| 1 x every minute| off| 1 x every minute| Dangerous CO condition detection whilst user was absent. Currently, no dangerous CO level present.
Fault| off| off| 2 x every minute| 2 x every minute| Fault warning.
End of life| off| off| 3 x every minute| 3 x every minute| Replace CO alarm ASAP.
Low battery| off| off| 1 x every minute| 1 x every minute| Replace CO alarm.
Low battery silence| off| Off| 1 x every minute| Muted| Mute 9 hours active.
HOW TO MUTE CO ALARM SOUND
CO alarm warning| ONLY AFTER RECOMMENDED ACTIONS HAVE BEEN TAKEN.
The CO alarm is due to dangerous levels of carbon monoxide.| Press cover TEST/SILENCE button 3 sec.
Low battery| | Press cover TEST/SILENCE button 3 sec.

GAS EMERGENCY SERVICE TELEPHONE NUMBER 0800 111 999
Contact numbers for other fuel appliances:
Oil users: Contact OFTEC on 0845 658 5080
Solid fuel users: Contact HETAS on 01684 278170

When will the Alarm be activated

If the CO level (PPM) in the room is too high, the carbon monoxide alarm switches to the alarm mode according to the scheme below:

  • 027PPM ± 03PPM : No alarm signal
  • 055PPM ± 05PPM : Alarm signal between 60 – 90 minutes1
  • 10PPM ± 10PPM : Alarm signal between 10 – 40 minutes
  • 30PPM ± 30PPM : Alarm signal within 3 minutes

Health effects of carbon monoxide

  • ~ – 00100PPM : Slight headache, flushing of skin (indefinite exposure).
  • 200 – 00300PPM : Headache (5 – 6 hour exposure)
  • 400 – 00600PPM : Severe headache, weakness, dizziness, nausea, vomiting (4 – 5 hour exposure)
  • 1100 – 01500PPM : Increased pulse and breathing rate, syncope (fainting), coma, intermittent seizures (4 – 5 hour exposure)
  • 5000 – 10000PPM : Weak pulse, depressed respiration / respiratory failure, death (1 – 2 minutes exposure)

This CO alarm may not prevent the chronic effects of carbon monoxide exposure and that the CO alarm will not fully safeguard individuals at special risk.’

Maintenance

The CO alarm does not require any maintenance other than to clean the outside case occasionally with a clean tissue. Ensure that the holes on the front of the CO alarm are not blocked with dust or dirt.

We recommend to manually test the CO alarm once a month by pressing and holding the TEST/SILENCE button. If problems are found, the CO alarm switches to the error mode (either siren error or sensor error). Dust is a major cause of false alarms. Therefore, clean the CO alarm once a month. Use a vacuum cleaner to gently remove any accumulated dust along the sides of the CO alarm. Never use a wet cloth or detergent to clean your CO alarm, as this can be harmful to the sensor.

Warnings

This manual contains important safety information about the installation and operation of the CO alarm. Read the manual carefully and keep it in a safe place for future reference. The CO alarm should be installed by a competent person. Installation of a CO alarm should not be used as a substitute for proper installation, use and maintenance of fuel burning appliances including appropriate ventilation and exhaust systems. This CO alarm is not water resistant and is only suitable for indoor use. Do not try to repair the CO alarm, it has the risk of electric shock or malfunction if the CO alarm is tampered with.

Do not expose the CO alarm and batteries to extreme temperatures. Some common household substances can affect the sensitivity of the CO alarm. Do not use household cleaners, polishes, perfumes or aerosol sprays on or close to the CO alarm. Avoid the use of nail polish remover, model paint or model glue close to the CO alarm. This CO alarm is designed to protect individuals from the acute effects of carbon monoxide exposure. It will not fully safeguard individuals with specific medical conditions. If in doubt consult a medical practitioner. Long exposure to low levels (>10 ppm) of CO may cause chronic effects. If in doubt consult a medical practitioner.

Specifications

  • Gas detected : Carbon Monoxide
  • Lifetime : 10 years
  • Power supply : Long life lithium battery, 3 V, sealed for the life of the product (no replacement necessary)
  • Installation : Wall mount, ceiling
  • Dimensions : 95 mm x 95 mm x 25 mm
  • Weight : 120 g
  • Audible : ≥85 dB@3m
  • Sensor technology : Electrochemical Cell
  • Type of device : Type-B
  • Operation Ambient Condition : Temperature -10°C to +40°C
  • Humidity : 25 – 95% RH (non-condensing)
  • Storage/Transport Ambient Condition : Temperature -15°C to +45°C
  • Humidity:  20 – 95% RH (non-condensing)
  • IP rating : IP44

Service and contact

For questions about the installation, use or operation of this CO alarm please visit www.resideo.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.

Symbols

When the CO alarm has come to the end of its life, dispose of it in accordance with local regulations. It is classified as electronic waste and contains a battery and therefore should be disposed of separately from household waste.

The CO Alarm is certified by BSI to the European standard EN 50291-1 “Electrical apparatus for the detection of carbon monoxide in domestic premises” and EN50291-2 “Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft”. It conforms to the General Product Safety Directive (GPSD), the Electromatic Compatibility Directive (EMC) and the Restriction of Hazardous Substances Directive (RoHS).

Disclaimer
This CO alarm is designed to alert you to a potentially dangerous build-up of Carbon Monoxide gas. It is not designed to remedy a Carbon Monoxide problem nor to locate a specific source of Carbon Monoxide. Resideo shall not be liable to pay for any Carbon Monoxide investigation or service call carried out or arranged in response to an alarm

WARRANTY

RESIDEO’S 10 YEAR WARRANTY POLICY R100C-1, R200C-1, R200C-2, R200C-3, R200C-N1, R200C-N2, R200C-N3, R200H-N1, R200H-N2, R200S-1, R200S-2, R200S-3, R200S-N1, R200S-N2, R200S-N3, R200ST-N1, R200ST-N2, R200C2-A, R200C2-A-UK, R200C2-B, R200C2-E, Beneficiary of this Warranty This limited warranty is provided to its direct customer (“Buyer”) by the member of the Resideo Technologies, Inc group of companies (“Resideo”) which sells the product. Resideo does not provide this warranty to the consumer or end-user of the product. Resideo expects that Buyer will give its customers an equivalent warranty to that given by Resideo to Buyer hereunder. This does not affect any statutory obligations that Resideo may have to consumers as manufacturer of the Products.

Resideo reserves the right, at its discretion, to change these Warranty Terms and the products to which these Warranty Terms apply. Any changes to these Warranty Terms only apply to Products sold after the date of the change. Resideo’s Warranty Resideo warrants that the Products will be free from defective materials and faulty workmanship and conform to applicable specifications for a period of 120 months from the manufacturing date code on the Product. If any Product becomes defective during the applicable warranty period for a reason that is not excluded below, Resideo will, at its sole option, either repair or replace free of charge with a new or refurbished product, or credit to Buyer’s account the price paid for the Product.

Resideo will not be responsible for any of Buyer’s costs of de-installing and reinstalling the Product, travel or any other costs. Exclusions from the Warranty This warranty is an extended manufacturer’s warranty and to the extent permitted by law, is in lieu of all other warranties and conditions, expressed or implied including those of satisfactory quality or fitness for a particular purpose. Resideo shall have no obligation under this warranty or otherwise if: i) The product is not installed in accordance with Resideo’s installation instructions and applicable installation standards, is not used for a purpose for which it is designed and in accordance with Resideo’s user instructions or is not maintained in accordance with Resideo’s care and maintenance instructions or is altered (including the alteration of any serial number), serviced or repaired by anyone other than Resideo/Resideo’s Authorized Service/Repair Centre: ii) Damage is caused by outside occurrences, such as lightning, power surges, fire, floods, acts of nature, or the like or quality of water, or is caused by misuse, or vandalism; or iii) A defect is not caused by reason of defective materials or workmanship. iv) This warranty does not cover the re-changeable battery used in R200C2-A, R200C2-A-UK, R200C2-B, R200C2-E. This warranty does not cover the costs of replacing consumable items (such as batteries), maintenance checks and adjustments, such as Product calibration, which may be required in accordance with the Product use and maintenance instructions. Returns and Repairs Prior to returning any Product that has become defective during the applicable warranty period for a reason that is not excluded under these Warranty Terms, Buyer must contact Resideo customer service to obtain a return merchandise authorization (RMA) number. To obtain the RMA number, Buyer must provide: i) Product model number and serial number, ii) Proof of purchase, iii) Description of the defect. Buyer shall send the defective Product to Resideo at its own expense, appropriately packaged to prevent damage to the Product, together with the RMA and proof of purchase, in accordance with the instructions of the Resideo customer service representative. Resideo will test the returned Product to verify that it is defective.

At Resideo’s request Buyer shall provide such additional information as Resideo may reasonably require to verify the cause of the defect, including date and location of installation, Product application, manner of operation, maintenance records and failure mode. If Resideo determines that the Product is defective, Resideo will decide whether to repair or replace the Product or credit the Product purchase price to Buyer’s account. If Resideo decides to replace the Product, Resideo will send the replacement Product to Buyer at Resideo’s expense. Unless otherwise agreed in writing, Resideo will destroy any Product that it determines to be defective. If Resideo does not find the Product defective, Resideo reserves the right to charge the Buyer for the reasonable costs of its investigation of the alleged defect. If Buyer pays Resideo in advance for the costs of returning the Product, Resideo will send the non-defective Product back to Buyer but otherwise Resideo will destroy the Product. Out of Warranty Repairs At the request of Buyer, Resideo will provide to Buyer a quotation for the costs to repair any Product outside of the applicable warranty period, if Resideo considers such Product to be repairable. If Buyer accepts the quotation and sends the Product to Resideo (following the same process as for in-warranty returns), Resideo will repair the Product in accordance with the quotation and return the repaired Product to Buyer. The repaired Product will be warranted for 90 days from the date of repair. Miscellaneous If any part of these Warranty Terms is prohibited by applicable laws, the relevant part shall be null and void, but the remainder of the Warranty Terms shall remain in full force and effect

Security Communications SAS
1198 Avenue Maurice Donat
06250 Mougins, France
www.resideo.com

© 2021 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliate.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

resideo User Manuals

Related Manuals