tp-link TL-SF1008LP Unmanaged Desktop PoE-PoE+ Switch Installation Guide

June 9, 2024
tp-link

tp-link TL-SF1008LP Unmanaged Desktop PoE-PoE+ Switch

tp-link TL-SF1008LP Unmanaged Desktop PoE-PoE+ Switch

LED Explanation

Power

  • Off: Power off

PoE Status

  • On: PoE power provided
  • Flashing: Current-overload/ Short-circuit Off: No PoE power provided

Link/Act

  • On: Link present but no activity Flashing: Transmitting/receiving data Off: No link

TL-SF1008LP

  • Off: Total power supply < 34 W
  • On: 34 W ≤ Total power supply < 41 W Flashing: Total power supply ≥ 41 W

TL-SF1008P

  • Off: Total power supply < 59 W
  • On: 59 W ≤ Total power supply < 66 W Flashing: Total power supply ≥ 66 W

TL-SF1009P/TL-SL1311P

  • Off: Total power supply < 58 W
  • On: 58 W ≤ Total power supply < 65 W Flashing: Total power supply ≥ 65 W

TL-SL1311MP

  • Off: Total power supply < 117 W
  • On: 117 W ≤ Total power supply < 124 W Flashing: Total power supply ≥ 124 W

Switches Explanation

Note: The numbers in brackets indicate the ports where the feature takes effect. For example, when Extend(1-4) is toggled to On, the Extend mode will be enabled for ports 1-4.

  • Extend (for TL-SF1008LP/TL-SF1008P/TL-SF1009P/TL-SL1311P/TL-SL1311MP)
  • Recovery (For TL-SF1008P/TL-SL1311P/TL-SL1311MP)
  • Off: Ports run at 10/100 Mbps and support PoE power supply up to 100 m away.
  • On: Ports run at 10 Mbps and support PoE power supply up to 250 m away.
  • Priority (For TL-SF1008LP/TL-SF1008P/TL-SF1009P
  • Off: All the ports transmit data with the same priority.
  • On: The specific ports transmit data with a higher priority than other ports.
  • Off: Ports can transmit data with each other.
  • On: Specfic ports cannot transmit data with other downlink ports.

They can transmit data only with the uplink ports.

Connection

tp-link TL-SF1008LP Unmanaged Desktop PoE-PoE+ Switch
1

Note:

  1. PoE ports can also connect to non-PoE devices, but only transmit data.
  2. TL-SL1311MP/TL-SL1311P has three uplink ports, which typically connect to uplink devices like routers. Uplink 1 is an SFP slot and works with a 1000 Mbps SFP module. Uplink 2 and uplink 3 are RJ45 ports.

Specifications

tp-link TL-SF1008LP Unmanaged Desktop PoE-PoE+ Switch
2

Frequently Asked Questions (FAQ)

Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the Power LED is not lit, please check as follows:
A1: Make sure the AC power cord is connected the switch with power source properly.
A2: Make sure the voltage of the power supply meets the requirements of the input voltage of the switch.
A3: Make sure the power source is on.
Q2. The Link/Act LED is not lit when a device is connected to the corresponding port.
It is recommended that you check the following items:
A1: Make sure that the cable connectors are firmly plugged into the switch and the device.
A2: Make sure the connected device is turned on and working well.
A3: The cable must be less than 100 meters long (328 feet). If Extend Mode is enabled, it

Q3. Why are PoE ports not supplying power for PoE devices?
When the total power consumption of connected PoE devices exceeds the maximum, the PoE port with a smaller port number has a higher priority. The system will cut off power to the ports with larger port numbers to ensure supplying to other ports. Take TL-SF1008P as an example. If port 1, 2 and 4 are consuming 15.4 W respectively, and an additional PoE device with 20 W is inserted to port 3, the system will cut off the power of port 4 to compensate for the overload.

Q4. What should I notice before using the PoE Auto Recovery feature?

A1: Before upgrading a connected PoE powered device (PD), disable PoE Auto Recovery to avoid the PD’s damage.
A2: When a PD does not send data packets to the switch for a long period in certain scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to avoid the PD repeatedly rebooting.

EU declaration of conformity

TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and (EU)2015/863. The original EU declaration of conformity may be found at https://www.tp- link.com/en/support/ce/
UK declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016. The original UK declaration of conformity may be found at https://www .tp-link.com/support/ukca/

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us. Place the device with its bottom surface downward.
  • Do not use damaged charger or USB cable to charge the device.
  • Do not use any other chargers than those recommended.
  • Adapter shall be installed near the equipment and shall be easily accessible.
  • The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be easily accessible.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals