JBC JTSE Power Hot Air Control Unit Instruction Manual

June 9, 2024
JBC

JBC JTSE Power Hot Air Control Unit Instruction Manual

This manual corresponds to the following references:

JTSE-1UA (100V / 120V)
JTSE-2UA (230V)

Packing List

The following items are included:

Packing List

Features and Connections

Features and Connections

Features and Connections Continued

JTSE / TESE Work Screen

The work screen offers an intuitive user interface which provides quick access to station parameters. Default PIN: 0105

JTSE - TESE Work Screen

JTSE - TESE Work Screen Continued

Troubleshooting

Station troubleshooting available on the product page at www.jbctools.com

Advanced Functionalities

By pressing Graphics in the main MENU, temperature and power fi gures in real time are displayed. This helps you decide which nozzle to use to obtain the best quality solder joints.

Graphics Continued

Advanced Functionalities
The first system to optimize traceability in soldering

  • Get greater quality and control in your production
  • Manage your whole soldering process remotely in real time

Station Update
Download the JBC Update File from www.jbctools.com/software.html
Insert the USB flash drive with the file downloaded to the station.

System Notifications

The following icons will be displayed on the screen’s status bar.

USB flash drive is connected.

Station is controlled by a PC.

Station is controlled by a robot.

Station software update. Press INFO to start the process.

Warning. Press INFO for failure description.

Error. Press INFO for failure description, the type of error and how to proceed.

Adjustable Stand

Adjust the tool holder angle to suit your work position.

Operation Modes

  1. From the Tool Settings Menu, select the mode to activate the tool depending on the task.
    Operation Modes Figure 1

  2. The tool stops blowing when pressing the start/stop button.
    If the stand is connected to the station and for safety it will also stop when returned to the stand.

Operation

Operation

Protectors & Extractors

Protectors and Extractors

Accessories (not included)

Accessories

Accessories Continued

Using the Thermocouple Type K

Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor.
You can define its use mode by means of the “Ext TC mode” option in the “Tool” menu.

You can choose from two work modes:

Regulation: the station regulates the air temperature automatically to maintain the External Thermocouple (TC) temperature.

Protection: the station cuts the air supply off when the External Thermocouple (TC) temperature is reached.

Work Modes

IPC* does not recommend exceeding ramp-up rates over 3-4ºC / sec. (5-7ºF / sec) so as to reduce the risk of thermal stress on the PCB.

* IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits.

Nozzle Extractor

Turn the tool off and handle it with care. The heating element and the nozzle are still hot.

Nozzle Extractor

Compatible Nozzles

JTT works with JT nozzles. Find the model that best suits your soldering needs at www.jbctools.com

In case of a loosely fitting nozzle:

Nozzle Assembly

Replacing the Heating Element

Note: Only perform this operation when the element is cold and the unit is disconnected from the mains.

Loosen the screw (1) and pull the worn heating element out of the handle (2).

Insert the new heating element, make sure its pushed all the way in (2) and tighten the screw (1).

Replacing the Heating Element

Changing the JTT Heater Hose Set


Note: Only perform this operation when the station is turned off.

Use a spanner to unscrew the nut (1) and remove the tool hose from the control unit (2).

Insert the new hose, make sure it is pushed all the way into the connector (2), and tighten the nut (1).

Maintenance

Before carrying out maintenance, always allow the equipment to cool.

  • Clean the station screen with a glass cleaner or a damp cloth.
  • Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
  • Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool’s status.
  • Periodically check all cables and tubes. – Replace a blown fuse as follows:

Maintenance

  • Replace any defective or damaged pieces. Use original JBC spare parts only.
  • Repairs should only be performed by a JBC authorized technical service.

Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.

  • Do not use the units for any purpose other than soldering or rework. Incorrect use may cause a fire.
  • The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
  • Do not work on electrically live parts.
  • The tool should be placed in the stand when not in use in order to activate the sleep mode. The soldering tip or nozzle, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.
  • Do not leave the appliance unattended when it is on.
  • Do not cover the ventilation grills. Heat can cause inflammable products to ignite.
  • Avoid flux coming into contact with skin or eyes to prevent irritation.
  • Be careful with the fumes produced when soldering.
  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
  • Utmost care must be taken with liquid tin waste which can cause burns.
  • This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning the use of the appliance and understand the hazards involved. Children must not play with the appliance.
  • Maintenance must not be carried out by children unless supervised.

Specifications

JTSE

Power Hot Air Control Unit

Ref.: JTSE-1UA 100V – 120V 50/60Hz. Input fuse: 8A. Rated current: 7A
Ref.: JTSE-2UA 230V 50/60Hz. Input fuse: 4A. Rated current: 3A

  • Temperature selection: Room temp. 150 – 450 °C / 300 – 840 °F

  • Nominal power: 700W

  • Cool mode: T off. Used to blow air to room temperatur

  • Ambient operating temp.: 10 – 50 ºC / 50 – 122 ºF

  • Air flow regulation: 5 – 50 SLPM

  • Vacuum: 30% / 228 mmHg / 9 inHg

  • Connectors:
    USB-B
    RJ-12
    P-005 Pedal

  • Control Unit Dimension/Weight: 1.90 kg / 4.2 lb
    (L x W x H) 230 x 148 x 160 mm / 5.83 x 7.24 x 5.51 in

  • Total Net Weight:

  • Total Package Dimension/Weight: 258 x 328 x 208 mm / 2.56 kg
    (L x W x H) 10.15 x 12.9 x 8.2 in / 5.64 lb

Complies with CE standards.
ESD safe.

Warranty

JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour.

Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.

Get 1 extra year JBC warranty by registering here:https://www.jbctools.com/productregistration/ within 30 days of purchase.

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility.