The F4XIP Quick Reference Guide (QRG) has basic product information such as connection and mounting. Download the User Manual from www.chauvetprofessional.com for more details.

Disclaimer
The information and specifications contained in this QRG are subject to change without notice.

LIMITED WARRANTY

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com /warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu/warranty- registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance.

  • DO NOT open this product. It contains no user-serviceable parts.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
  • CAUTION: This product’s housing may be hot when lights are operating.
  • DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
  • USE a safety cable when mounting this product overhead.
  • DO NOT submerge this product (IP65). Regular outdoor operation is fine.
  • DO NOT operate this product if the housing, lenses, or cables appear damaged.
  • DO NOT connect this product to a dimmer or rheostat.
  • ONLY connect this product to a grounded and protected circuit.
  • ONLY use the hanging/mounting bracket or the handles to carry this product.
  • In the event of a serious operating problem, stop using immediately.
  • The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher temperatures.
  • The minimum ambient temperature is -4°F (-20°C). Do not operate the product at lower temperatures.

FCC Compliance

This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.
    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact Us at the end of this QRG for contact information.

What is Included

  • 4 F4XIP products
  • 1 Seetronic® Powerkon® IP65 power cord
  • 4 Seetronic® Powerkon® IP65 power linking cords
  • 4 Seetronic® Etherkon® IP65 signal linking cords
  • Road case
  • 5 spare masks
  • Module removal tool
  • Quick Reference Guide

AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.

AC Plug

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green

To eliminate unnecessary wear and improve its lifespan, during periods of non- use completely disconnect the product from power via breaker or by unplugging it.

Power Linking
It is possible to power link up to 36 F4XIP products at 100 V, 40 products at 120 V, 57 products at 208 V, 66 products at 230 V or 240 V, or up to 72 products at 277 V. Never exceed this number. Power-linking cables can be purchased separately.

Signal Connection
The F4XIP can link to a VIP Drive 83R Nova or a VIP Drive 10-5 Nova from CHAUVET using an Ethernet connection.
Download the User Manual for the VIP Drive 83R Nova or the VIP Drive 10-5 Nova from www.chauvetprofessional.com for more details.

Connection Diagram

Chauvet-F4XIP-QRG-ML5-SMD-LED-Video Panel-1

Mounting

Before mounting this product, read the Safety Notes. Use rig bars (DRB- F50CMIP, DRB-F100CMIP, DRB-F50CM, or DRB-F100CM) from CHAUVET, or the M12 threaded mounting holes on the product. Make sure the mounting devices are capable of supporting the weight of the product. For more information on how to mount the F4XIP, download the User Manual from www.chauvetprofessional.com. For our Chauvet line of mounting clamps, go to http://trusst.com/productcategory /truss-clamps/.

Mounting Diagram

Chauvet-F4XIP-QRG-ML5-SMD-LED-Video Panel-2

Warning! The magnetic attachments are not load-bearing, and are intended for alignment assistance only. Do not release panel until the hanging hardware has been fully secured.

  • The M12 mounting points are not intended for hanging or suspending from a truss or other overhead structure.

Contact Us

General Information Technical Support
Chauvet World Headquarters
Address: 3360 Davie Rd. Voice: 844-393-7575
Davie, FL 33314 Fax: 954-756-8015
Voice: 954-577-4455 Email: chauvetcs@chauvetlighting.com
Fax: 954-929-5560
Toll Free: 800-762-1084 Website: www.chauvetprofessional.com

Chauvet U.K.
Address: Unit 1C Email: UKtech@chauvetlighting.eu
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK Website: www.chauvetprofessional.eu
NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110

Chauvet Benelux
Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
9770 Kruishoutem
Belgium Website: www.chauvetprofessional.eu
Voice: +32 9 388 93 97

Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S.,U.K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.

UL 60950-1
CSA C22.2 No. 60950-1
E113093-1110, E113093-1125

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet User Manuals

Related Manuals