Midea MPPD33H Remote Controller Owner’s Manual
- June 9, 2024
- Midea
Table of Contents
Midea MPPD33H Remote Controller Owner's Manual
IMPORTANT NOTE: Thank you for purchasing our air conditioner. Please read this manual carefully before operating your new air conditioning unit. Make sure to save this manual for future reference.
Remote Controller Specifications
Quick Start Guide
NOT SURE WHAT A FUNCTION DOES? Refer to the How to Use Basic Functions and How to Use Advanced Functions sections of this manual for a detailed description of how to use your air conditioner.
SPECIAL NOTE
- Button designs on your unit may differ slightly from the example shown.
- If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
- When there are wide differences between “Remote controller Manual” and “USER’S MANUAL” on function description, the description of “USER’S MANUAL” shall prevail.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries(some units). Put the
batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws
for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL
- The remote control must be used within 8 meters of the unit.
- The unit will beep when remote signal is received.
- Curtains, other materials and direct sunlight can interfere with the infrared signal receiver.
- Remove batteries if the remote will not be used more than 2 months.
NOTES FOR USING REMOTE CONTROL
The device could comply with the local national regulations.
- In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
- In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
Buttons and Functions
Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.
NOTE: Press SET button to select the operation functions in the following
order: Fresh( ) AP mode( ) Fresh… The selected symbol will flash on the
display area, press the OK button to confirm.
Fresh feature is not available for models of RG10F(D)/BGEF, RG10F(E)/BGEF and
RG10F(F/G/H/S)/BGEF.
NOTE: Press SET button to select the operation functions in the following
order: Fresh( ) I Sense ( ) AP mode( ) Fresh… The selected symbol will flash
on the display area, press the OK button to confirm.
Fresh feature is not available for models of RG10F2(D1)/BGEFU1,
RG10F2(E1)/BGEFU1 and RG10F2(F1/G1/H1)/BGEFU1.
ON/OFF Turns the unit on or off.
TEMP Increases temperature in 1 OC(1OF) increments. Max. temperature is 30
OC(86 OF).
TEMP Decreases temperature in 1 OC(1 OF) increments. Max. temperature is 17
OC(62 OF).
FAN SPEED Selects fan speeds in the following order: AUTO LOW MED HIGH NOTE:
Holding this button down for 2 seconds will activate Silence feature(some
units).
TIMER ON Sets timer to turn unit on (see How to Use Basic Functions for
instructions). MODE Scrolls through operation modes as follows: AUTO COOL DRY
HEAT FAN NOTE: HEAT mode is not supported by the cooling only appliance.
SHORTCUT Used to restore the current settings or resume previous settings. OK
Used to confirm the selected functions.
SWING Starts and stops the horizontal louver movement. Hold down for 2 seconds
to initiate vertical louver auto swing feature(some units).
TIMER OFF Sets timer to turn unit off (see How to Use Basic Functions for
instructions).
I SENSE Temperature sensing and room temperature display button.
SLEEP Saves energy during sleeping hours.
LED Turns indoor unit’s LED display and air condiioner buzzer(some units) on
and off , which create a comfortable and quiet environment.
°C/°F Press this button will alternate the temperature display between the °C
& °F.
LOCK Press together the two buttons simultaneously for 5 seconds to lock the
keyboard. Press together the two buttons for 2 seconds to unlock the keyboard.
Remote Screen Indicators
Information are displayed when the remote controller is power up.
Note: All indicators shown in the figure are for the purpose of clear presentation. But during the actual operation, only the relative function signs are shown on the display window.
How to Use Basic Functions
ATTENTION Before operation, please ensure the unit is plugged in and power is available.
SETTING TEMPERATURE The operating temperature range for units is 17-30°C (62-86°F)You can increase or decrease the set temperature in 1°C (1°F) increments.
AUTO Mode
NOTE:
- In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
- In AUTO mode, fan speed can not be set.
COOL or HEAT Mode
NOTE: As outdoor temperature drops, the performance of your unit’s HEAT function may be affected. In such instances, we recommend using this air conditioner in conjunction with other heating appliances.
DRY Mode
NOTE: In DRY mode, fan speed can not be set since it has already been automatically controlled.
FAN Mode
NOTE: In FAN mode, you can’t set the temperature. As a result , no temperature displays in remote screen.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically
turn on/off.
TIMER ON setting
TIMER OFF setting
NOTE:
- When setting the TIMER ON or TIMER OFF, the time will increase by 30 minutes increments with each press, up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
- Cancel either function by setting its timer to 0.0h.
TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours
after the current time.
Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.
How to Use Advanced Functions
Swing function
LED DISPLAY
FP function
The unit will operate at high fan speed (while compressor on) with temperature
automatically set to 8 C/46 F.
Note: This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting
temperature of 17 C/62 F to activate FP function. Press On/Off, Sleep, Mode,
Fan and Temp. button while operating will cancel this function.
SHORTCUT function
Press SHORTCUT button(some units)
Push this button when remote controller is on, the system will automatically
revert back to the previous settings including operating mode, setting
temperature, fan speed level and sleep feature (if activated).
If pushing more than 2 seconds, the system will automatically restore the
current operation settings including operating mode, setting temperature, fan
speed level and sleep feature (if activated ).
SLEEP function
The SLEEP function is used to decrease energy use while you sleep (and don t
need the same temperature settings to stay comfortable). This function can
only be activated via remote control. The sleep function is not available in
Fan or Dry mode.Please refer to the OWNER’S MANUAL for more details.
SET function
- Press the SET button to enter the function setting, then press SET button or TEMP or TEMP button to select the desired function. The selected symbol will flash on the display area, press the OK button to confirm.
- To cancel the selected function, just perform the same procedures as above.
- Press the SET button to scroll through operation functions as follows: Fresh ( ) I Sense( ) AP mode( ) []: If your remote controller has I Sense button, you can not use the SET button to select
the I sense feature.
FRESH function( ) (some units) : When the FRESH function is initiated, the ion generator is energized and will help to purify the air in the room.
AP function( )(some units) : Choose AP mode to do wireless network configuration. For some units, it doesn’t work by pressing the SET button. To enter the AP mode, continuously press the LED button seven times in 10 seconds.
I Sense function( ):
The I Sense function enables the remote control to measure the temperature at
its current location and send this signal to the air conditioner every 3
minutes interval. When using AUTO, COOL or HEAT modes, measuring ambient
temperature from the remote control(instead of from the indoor unit itself)
will enable the air conditioner to optimize the temperature around you and
ensure maximum comfort.
NOTE: Press and hold I Sense button for seven seconds to start/stop memory feature of I Sense function. For the remote controls without I Sense button, press and hold SLEEP button for seven seconds to start/stop the memory feature of I Sense function.
- If the memory feature is activated, Onp displays for 3 seconds on the screen.
- If the memory feature is stopped, OFp displays for 3 seconds on the screen.
- While the memory feature is activated, press the ON/OFF button, shift the mode or power failure will not cancel the I Sense function.