Tc max. of PCBA = 90°C
Measurement in LED nr D20.

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-03

WARNING

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-04

STANDARD VERSION

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-05 COMUNICATION BOXVERSION PHILIPS-Coreline-XL-BVP140-Tempo-Large-
Grey-06

LUMINAIRE FIXATION

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-07Do not forget to screw the bolt with the torque indicated PHILIPS-Coreline-XL-
BVP140-Tempo-Large-Grey-08

Never include more screws than indicated in this mounting instruction

If steel cable is used as 2nd fixation device:

  • Minimum section have to be of 3 mm
  • Maximum allowed length of 500 mm
  • Minimum M5 stainless steel or M5 Xylan in SPO (no stainless steel.
  • SPO version: steel cable with Xylan treatment (no stainless steel).

Fixation screws, washers or nuts:

  • Standard version and MSP: Stainless steel
    • EN-10027-2: 1.4301 (X5CrNi18-10)
    • AISI:304
    • ISO: A2
  • SPO version: Steel with Xylan treatment (no stainless steel!)

SETTILT PHILIPS-Coreline-XL-BVP140-Tempo-Large-
Grey-09 PHILIPS-Coreline-XL-BVP140-Tempo-Large-
Grey-10COMUNICATION BOX INSTALLATION/ FIXATION PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-11 PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-12

TYPES OF CONNECTION

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-13 PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-14

TECHNO CONNECTOR

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-15

COLOSIO CONNECTOR PHILIPS-Coreline-XL-BVP140-Tempo-Large-
Grey-16

GLASS MAINTENANCE INSTRUCTION

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-17 PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-18

  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  • The maintenance of the luminaire can’t be done on the pole.

SRG 10 –
10 KV PROTECTION

PHILIPS-BPP614-Urban-Lamp-Post-10* 10kV for L/N – GND non-conductive connection

For product with TAG LABEL

PHILIPS-Coreline-XL-BVP140-Tempo-Large-Grey-19

Annex I: Simplified EU Declaration of Conformity
Hereby, Signify Holding declares that the radio equipment type included into the luminary is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.philips.com/lighting

Signify Holding
Hereby, declares that the radio equipment type is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.philips.com/lighting

SR compatibility – For SR-based luminaires only SR-Certified components/sensors are to be used (see also: http://www.lighting.philips.co.uk/oem­
EMEA/products/driving-connected-lighting). The functional compatibility of two (SR-certified) components/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based luminaire, is to be released by the master component/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non- compliance for which Signify cannot take any responsibility.

Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control conductors.

The control gear and/or the external flexible cable contained in this RO luminaire shalt only be replaced by the manufacturer or his service agent or a similar qualified person. The light source contained in this luminaire is not replaceable, in case of damage replace the luminaire.

Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other nstructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.

This product contains a light source of energy efficiency class: see table or label.

2021 Signify Holding.
All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All other trademarks are owned by Signify Holding or their respective owners.

Signify Holding.
The Netherlands

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals