DRAWING 1 – MOUNTING Drawing 1 – Flush Mount

HINKLEY 30023BNG Roca Medium Convertible Pendant -
MOUNTING| HINKLEY 30023BNG Roca Medium
Convertible Pendant - Flush Mount
Drawing 2 – Chain Hung
HINKLEY 30023BNG Roca Medium Convertible Pendant - Chain
Hung
Drawing 3 – Post-Mount
HINKLEY 30023BNG Roca Medium Convertible Pendant - Post
Mount

Mounting Instructions 30023

  1. To begin installation, first attach mounting strap (A) to junction box using two 8-32 screws (B) NOT PROVIDED. Make sure the head of the ground screw is facing down – see DRAWING 1.
  2. Next take threaded tube (C) and thread one hex nut (D) onto end. Now thread end of tube (C) into hanging loop (E) approximately 1/2”. Then tighten hex nut (D) against back of hanging loop to lock thread tube in place.
  3. Now thread second hex nut (D) onto threaded tube (C). Now thread tube (C) into center of mounting strap (A) approximately 1/2”.
  4. Next it is necessary to adjust the position of hanging loop (E). This is accomplished by slipping the hanging loop (E) through the center hole in the ceiling canopy (F). Now thread hanging loop up or down until the top threaded portion of the loop is approximately 1/4” inside the canopy – see DETAIL 1. NOTE: A third hex nut (D) is supplied and can be threaded onto center tube (C) above the mounting strap (A) after adjustments are made to loop height.
  5. Now threaded medallion or screw collar ring [depending on hardware supplied] (H) and slide onto the fixture wire and over the stems that were attached to the fixture body earlier, followed by the canopy (F) -see DETAIL 2.
  6. Now lift fixture body and stems up to hanging loop (E). Using the single chain link supplied, hook the last loop on the fixture stem to the hanging loop (E), and close chain link.
  7. Slip fixture wire through center hole of hanging loop (E) and through threaded tube (C) until it exits above the mounting strap (A).
  8. Make all wiring connection following wiring instructions (IS18) provided.
  9. After wire connections are completed slide canopy (F) along stems and up to ceiling followed by medallion or screw collar (H). While holding canopy against ceiling, thread (H) onto hanging loop (E), to secure canopy to in place.
  10. Glass can now be installed. See Assemlby instrutcions.

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING ISREQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Note: Fixture can be mounted as a flush mount or pendent

I.S. 18 wiring grounding instructions

Wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unma rked side of the two-conduc for cord) to positive fixture lead (B) with appropriately sized twist on connector – see Dra wings 1 or 2.
  2. Connect nega tive supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unma rked side of the two-conduc for cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connect nega tive supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal. 0 If installing a wall moun t fixture, use caulk to seal gaps between the fixture mounting plate (backpla te) and the wall. This will help prevent water from entering the outlet box. If the wal I surface is lap siding, use caulk and a fixture moun ting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Flush Mount Fixtures
For positive ground ing in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture moun ting strap (M) with the ground screw (S) – see Draw in g 1. Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coa ted) under the head of the ground screw (5) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Draw in g 2.
Post-Mou nt Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.