steinel Faretti XLED PRO 240 S LED Spotlight Instructions

June 8, 2024
STEINEL

XLED PRO 240 S
XLED PRO 240
Follow written instructions!
steinel Faretti XLED PRO 240 S LED Spotlight -

Faretti XLED PRO 240 S LED Spotlight

steinel Faretti XLED PRO 240 S LED Spotlight - 1steinel Faretti XLED PRO 240 S LED Spotlight -
2steinel Faretti XLED PRO 240 S LED Spotlight -
3steinel Faretti XLED PRO 240 S LED Spotlight -
4steinel Faretti XLED PRO 240 S LED Spotlight -
5steinel Faretti XLED PRO 240 S LED Spotlight -
6steinel Faretti XLED PRO 240 S LED Spotlight -
7

About this document

Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or in part only with our consent.
– Subject to change in the interest of technical progress.
– All product dimensions in mm.

Symbols

Hazard warning!
Reference to other information in the document.

Note:
Diagrams without captions apply to all versions.

General safety precautions

Disconnect the power supply before attempting any work on the unit.

  • Installing the LED floodlight involves work on the mains voltage supply; installation must therefore be carried out professionally in accordance with the applicable national wiring regulations and electrical operating conditions (DE-VDE 0100, AT-ÖVE/ÖNORM E 8001-1, CH-SEV 1000).
  • The LED floodlight must be positioned so that it is not expected that anybody can stare into the light for any prolonged period from a distance of less than 0.3 m.
  • The floodlight enclosure heats up when the light is on. Only adjust the angle of the LED panel once it has cooled down.
  • Do not install the LED floodlight on (normally) flammable surfaces.

XLED PRO 240 S / XLED PRO 240

Proper use
– LED floodlight suitable for wall mounting outdoors.
– Fully swivelling LED panel.
– Can be used on its own or interconnected with other floodlights.

Non-intended use
– The LED floodlight cannot be dimmed.
Not dimmable

XLED PRO 240
– Wired interconnection.
– Operation via control dial.
XLED PRO 240 S
– The sensor-switched LED floodlight contains an infrared motion detector.
Movement triggers lights, alarms and many other devices. With the fully swivelling panel, the LED floodlight can be used at home to provide perfect illumination for lighting up property, or commercially for lighting up business premises. In conjunction with the opal cover, this extremely efficient technology provides wide-area lighting.
Models
– XLED PRO 240 S
– XLED PRO 240

XLED PRO 240 S package contents (Fig. 3.1)
XLED PRO 240 package contents (Fig. 3.2)
A corner wall mount is available as an accessory:

Graphite: 4.00784E+12
White: 4.00784E+12
Black: 4.00784E+12

XLED PRO 240 S adjustment range
(Fig. 3.3/3.4/6.4)
Adjustment range for XLED PRO 240
(Fig. 3.5/3.6/6.4)

XLED PRO 240 S product dimensions (Fig. 3.7/3.8)
XLED PRO 240 product dimensions (Fig. 3.9/3.10)
XLED PRO 240 S product components (Fig. 3.11)
A LED panel
B Enclosure
C Wall mount
D Twilight setting
E Time setting
F Sensor unit
G Ring cover
XLED PRO 240 product components (Fig. 3.12)
A LED panel
B Enclosure
C Wall mount
Luminous intensity distribution (Fig. 3.13)

Electrical installation

  • Switch OFF power supply. (Fig. 4.1)

Connecting the mains power supply lead
The supply lead is a 2 or 3-core cable:

L phase conductor (usually black, brown or grey)
L’ or ↓ phase conductor (usually black, brown or grey), in master/master or

master/slave mode only. Mains supply lead is used as connection lead for switching output.
N| neutral conductor (usually blue)
PE| protective-earth conductor (green/yellow)

Note:
The protective-earth conductor need not be connected for this product.
Wiring diagram, master/slave (Fig. 4.2)
Wiring diagram, master/master (Fig. 4.3)
Wiring diagrams, slave (Fig. 4.4)

Important:
Incorrectly wired connections will produce a short circuit later on in the LED floodlight or your fuse box. In this case, you must identify the individual conductors once again and reconnect them.
The light source of this LED floodlight cannot be replaced. If the light source needs to be replaced (e.g. at the end of its service life), the complete LED floodlight must be replaced.

Installation

  • Check all components for damage.
  • Do not use the product if the LED floodlight is damaged.
  • Select an appropriate mounting location, taking the reach and motion detection into consideration. (Fig. 5.1/5.2/5.3)
  • Align the LED floodlight. (Fig. 5.4)

The most reliable way to detect movement is given by mounting the LED floodlight to point across the direction in which people walk and by making sure no obstacles (e.g. trees, walls etc.) interrupt the line of sensor vision. (Fig.5.2/5.3)

Mounting procedure

  • Switch OFF power supply. (Fig. 4.1)

  • Undo retaining screw. (Fig. 5.5)

  • Detach enclosure (B) from wall mount (C). (Fig. 5.6)

  • Detach plug-in terminal from wall mount. (Fig. 5.7)

  • Mark drill holes.
    – Wall mounting with wall mount (Fig. 5.8)

  • Drill holes and fit ground plugs. (Fig. 5.9)

  • Fit sealing plug. (Fig. 5.10)
    – Power supply lead, concealed (Fig. 5.11)
    – Power supply lead, surface-mounted, with spacers (Fig. 5.12)

  • Connect conductors.
    – XLED PRO 240 (Fig. 5.13)
    An additional external load can be connected to N and L’/↓.
    – XLED PRO 240 Slave (Fig. 5.14)

  • Connect plug-in terminal. (Fig. 5.15)

  • Fit enclosure onto wall mount. (Fig. 5.16)

  • Screw in locking screw. (Fig. 5.17)

  • Switch ON power supply. (Fig. 5.17)

  • Make settings. ➜ “6. Function”

Function

XLED PRO 240 S
Factory settings
Time setting (E): 8 seconds
Twilight setting (F): 2000 lux, (daytime mode)

  • Remove ring cover from sensor unit. (Fig. 6.1)

Twilight setting (Fig.6.2/E)
The LED floodlight’s chosen response threshold can be infinitely varied from approx. 2 to 2000 lux.
– Control dial set to = daylight operation (independent of ambient brightness)
– Control dial set to = night-time operation (approx. 2 lux)

Time setting (Fig. 6.2/F)
The time you want the LED floodlight to stay on for (main light) is infinitely adjustable from approx. 8 seconds to a maximum of 15 minutes. Any movement detected before this time elapses will restart the timer.
– Control dial set to + = approx. 15 minutes
– Control dial set to – = approx. 8 seconds

The control dial must be turned to when adjusting the detection zone and performing the functional test in daylight.

Note:
When setting the detection zone, we recommend selecting the shortest time.

Note:
After the LED floodlight switches OFF, it takes approx. 1 second before it is able to start detecting movement again. The LED floodlight will only switch ON in response to movement once this period has elapsed.

  • Fit ring cover on sensor unit. (Fig. 6.3)

Other information:
Floodlight adjustment range (Fig. 6.4)
Shrouds (Fig. 6.5)
The film shroud can be used for masking out any number of lens segments to limit reach as required.
Inadvertent triggering is ruled out or the sensor can be targeted to watch over danger spots (Fig. 6.6).
Setting functions
– Setting via control dial
Note:
The settings last selected on the control will be used.

Operation/maintenance

The LED floodlight is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems.
Weather conditions may affect the way the LED floodlight works. Strong gusts of wind, snow, rain and hail may cause the light to come ON when it is not wanted because the sensor is unable to distinguish between sudden changes in temperature and sources of heat.
The detector lens may be cleaned with a damp cloth if it gets dirty (do not use cleaning agents).
Important note: the control gear cannot be replaced.

steinel Faretti XLED PRO 240 S LED Spotlight - 8

Disposal

Electrical and electronic equipment, accessories and packaging must be recycled in an environmentally compatible manner.

steinel Faretti XLED PRO 240 S LED Spotlight - 9 Do not dispose of electrical and electronic equipment as domestic waste.

EU countries only: Under the current European Directive on Waste Electrical and Electronic Equipment and its implementation in national law, electrical and electronic equipment no longer suitable for use must be collected separately and recycled in an environmentally compatible manner.

Manufacturer’s Warranty

As purchaser, you are entitled to your statutory rights against the vendor. If these rights exist in your country, they are neither curtailed nor restricted by our Warranty Declaration.
We guarantee that your STEINEL Professional sensor product will remain in perfect condition and proper working order for a period of 5 years. We guarantee that this product is free from material-, manufacturing- and design flaws. In addition, we guarantee that all electronic components and cables function in the proper manner and that all materials used and their surfaces are without defects.

Making Claims
If you wish to make a claim, please send your product complete and carriage paid with the original receipt of purchase, which must show the date of purchase and product designation, either to your retailer or contact us at STEINEL (UK) Limited, 25 Manasty Road, Axis Park, Orton Southgate, Peterborough, PE2 6UP, for a returns number.
For this reason, we recommend that you keep your receipt of purchase in a safe place until the warranty period expires. STEINEL shall assume no liability for the costs or risks involved in returning a product.
For information on making claims under the terms of the warranty, please go to www.steinel-professional.de/garantie
If you have a warranty claim or would like to ask any question regarding your product, you are welcome to call us at any time on our Service Hotline 01733 366700.
5 YEAR MANUFACTURER’S WARRANTY

Technical specifications

| XLED PRO 240 S neutral white| XLED PRO 240 S warm white| XLED PRO 240
---|---|---|---
Dimensions (H x W x D)| 221 x 180 x 161 mm| 221 x 180 x 161 mm| 199 x 180 x 161 mm
Supply voltage| 220-240 -V / 50/60 Hz
Power consumption (Pon)| 19.30 W| 19.30W| 19.30W
Efficiency| 125 Im/VV| 110 Im/VV| 110 Im/VV
Luminous flux / brightness| 2407 Im| 2124 Im| 2124 Im
Standby (sensor) (Psb)| 0.50 W| 0.50 W| –
Weight| 0.620 kg| 0.620 kg| 0.480 kg
Colour temperature| 4,000 k (neutral white)| 3,000 k (warm white)| 3,000 k (warm white)
Area illuminated| Front view 316.2 cm2
Side view: 115 cm2| Front view: 274.1 cm2 Side view: 86.3 cm2
Mains current| 103 mA
Power factor| 0.74
Colour rendering index| IR, z 82
Average rated life expectancy| L70B50 at 25°C: >60,000 hours
Colour consistency SDCM| Starling value: 3
Additional switching capacity| Incandescent / halogen lamp load Fluorescent lamps, electronic ballast Fluorescent lamps, uncorrected Fluorescent lamps, series-corrected Fluorescent lamps, parallel-corrected Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W Capacitive load| 1,000 W
30 W
500 VA
900 VA
500 VA
1,000 VA
16W
64W
64W
88 pF|
Luminous intensity distribution|
Sensor systems| Passive infrared| –
| |
Reach| max. 12 m| –
Angle of coverage| 240°| –
Time setting| 10 s – 15 min| –
Twilight setting| 2-2,000 lux| –
IP / protection class| IP44 / II

Troubleshooting

Malfunction Cause Remedy
LED floodlight without power  ■  Fuse has blown, not switched ON, break in

wiring
■ Short circuit|  ■ New fuse, turn on power switch, check wiring with voltage tester
■ Check connections
Sensor-switched LED floodlight will not switch ON|  ■ Twilight setting in night-time mode
during daytime operation
■ Mains switch OFF
■ Fuse blown
■ Detection zone not correctly
adjusted|  ■ Reset
■ Switch ON
■ Replace fuse, check connection if necessary
■ Readjust
Sensor-switched LED floodlight will not switch OFF|  ■ Continued movement within the
detection zone|  ■ Check zone and readjust if necessary or apply shroud
Sensor-switched LED floodlight keeps switching ON and OFF|  ■ Animals moving in detection zone|  ■ Tilt sensor higher or fit shrouds to target sensor; adjust detection zone or fit shrouds
Sensor-switched LED floodlight switches ON when it should not|  ■ Wind is moving trees and bushes in the detection zone
■ Cars in the street are detected
■ Sudden temperature changes due to weather (wind, rain, snow) or air expelled from fans, open windows
■ Sensor-switched LED floodlight swaying (moving), resulting, for example, from gusts of wind or heavy precipitation|  ■ Change detection zone
■ Change detection zone
■ Adjust detection zone or install in a different place
■ Fit sensor-switched LED floodlight to a firm surface

www.steinel.de/contact
Contact
STEINEL Vertrieb GmbH
Dieselstraße 80-84
33442 Herzebrock-Clarholz
Tel: +49/5245/448-188
www.steinel.de
110081321 12/2021
Subject to technical modification without notice.

References