GARDENA 4040 modular Watering Controller User Manual
- June 8, 2024
- Gardena
Table of Contents
4040 modular Watering Controller
User Manual 4040 modular Art. 1276
Translation of the original instructions from German.
Please read these operating instructions carefully and observe the information
they contain. Use these operating instructions to familiarise yourself with
the product, the proper use and the safety instructions.
For safety reasons, children and young people under the age of 16, as well as
people not familiar with these operating instructions, should not use this
product.
Persons with reduced physical or mental abilities may use the product only if
they are supervised or instructed by a responsible person.
→ Please keep these operating instructions in a safe place.
1. Where to Use your GARDENA Watering Controller . . . . . . . . . . 13
2. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . 14
3. Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . 14
4. Putting into Operation . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . 15
5. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . 17
6. Trouble-Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . 21
7. Putting Out of Operation . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . 22
8. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 22
9. Service / Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . 23
Where to Use Your GARDENA Watering Controller
Proper use
The watering controller is suitable for indoor and outdoor use.
This Watering Controller is part of a garden irrigation system.
Recommended accessories: the watering valve (24 V) Art. 1278, the valve boxes
Art. 1254 / 1255 and the connection cable Art. 1280 and the cable clips Art.
1282.
These products allow you to set up fully automatic irrigation systems, which
can be designed to cater for varying water requirements of different plant
areas and ensure that the entire system functions correctly in case of
insufficient water supply.
Compliance with the operating instructions provided by GARDENA is a
prerequisite for proper use of the Watering Controller.
Please note
The Watering Controller must only be used for controlling 24 V (AC) valves.
Safety Instructions
Watering Controller:
The Watering Controller must only be operated with the 24-V (AC) power supply
unit provided.
- Protect the 24-V (AC) power supply unit from moisture when connected.
The Watering Controller (without power supply unit) is splash proof.
→ Avoid, however, spraying the Watering Controller directly with water.
To prevent loss of data if a power failure occurs, only use a 9 V alkaline battery IEC 6LR61 to buffer data. We recommend using batteries manufactured by Duracell and Energizer (do not use rechargeable batteries).
Function
-
% Run-Time key: Calls up the % Run Time function.
-
Man key:
Opens /closes individual channels manually. -
Time key:
Displays the time. -
OK-key:
Confirms the settings you selected using the ▲-▼ keys. -
Man. All key:
Opens /closes all the channels automatically in sequence. -
▲-▼ keys:
For changing or advancing specified data already entered (if you press and hold down one of the ▲-▼ keys you can change data in the quick run-through mode). -
Reset key:
Deletes all program data. -
Channel key:
Calls the channels.
Watering Controller display -
Program Display:
Indicates which program of the particular channel the Watering Controller is currently executing. If several channels are opened
at the same time, the program indicator is no longer displayed. -
Key Lock :
To enable/disable the key lock, press the Man key and the OK key simultaneously (the Reset key cannot be locked). -
Manual Control Display:
The display shows Man when manual control is activated. -
Channel Mode Display:
Modes: open, locked and program overlap. -
Watering Display:
If a channel is just being opened, the drops on the watering display flash alternately.
Putting into Operation
Connecting your Watering Controller:
Before programming your Watering Controller, install a 9-V battery to prevent loss of data if a power failure occurs.
-
Raise cover 1 and pull downwards.
-
Insert the cable of the power supply unit into the 24VAC terminals and screw tight.
The wiring diagram is located inside the cover 1. -
Insert cables for the valves (e. g. 7-wire GARDENA connection cable Art. 1280 for up to 6 valves) in the clips with the numbers and C and screw tight. (see also “Connect valves” ).
-
If necessary, insert the sensor cable (e. g. GARDENA moisture sensor Art. 1187 ) in the sensor connection 3.
-
If you intend to use the master channel (e. g. Art. 1273), insert the cable for the master channel into the terminals labelled M and C (Pump) and screw tight. (see “Master Channel” ).
-
Insert battery into the battery compartment 2.
Observe correct polarity. -
Push cover on to the connection box.
-
Plug the mains plug of the 24 V (AC) power supply unit into
a 230 V mains socket.
After this it is necessary to choose between a 24 hour or 12 hour display and the time must be set (see 5. Operation “Setting the time” ).
Connect extension module:
The GARDENA extension modules Art. 1277 with 2 channels are available as an optional extra. Up to 4 expansion modules can be connected and in this way 12 channels can be controlled via the base unit.
-
Break off bar 4 from the watering controller (or already connected expansion module).
-
Insert connection links 8 into the watering controller (or an expansion module already connected) and push the expansion module on.
-
Secure expansion module via the clamps 9.
-
Connect the expansion module cable 5 using the connector 6 (if connecting another expansion module, connect the expansion modules using the expansion module connector
The expansion modules are detected immediately by the watering controller when connected. -
Push on cover of watering controller and the expansion module.
Master Channel:
The master channel is a channel that can be operated at the same time as
other channels. This is important, for example, if you want to use a pump to
supply your irrigation system with water and if the pump should always be
activated each time an irrigation valve is activated. The master channel
closes 20 seconds before the end of the program so that the system is not
under pressure.
The pump can be operated, for example, using the GARDENA Pump Control Art.
1273 that is connected to the master channel.
Connecting valves:
Example: with 2 valve boxes V3 (Art. 1255)
Labelling the valves:
-
Label the valves (1 – 6), so that the channels (1 – 4) of the Watering Controller and the channels (5 and 6) of the expansion module can be clearly assigned to the valves.
Connecting the valves to the Valve Box: -
Connect one cable of the valve V1 to the cable terminal 1 of the valve box.
-
Connect the other cable of the valve V1 to a cable terminal C of the valve box (All 4 cable terminals C are interconnected and equivalent to one another).
-
Connect one cable of the valve V2 to the cable terminal 2 of the valve box.
-
Connect the other cable of the valve V2 to a cable terminal C of the valve box.
Other valves can be connected similarly to V1 and V2.
Connecting the Watering Controller to the Valve Box: -
Connect a cable terminal C of the Watering Controller to a cable terminal C of the valve box. Both cable clips C are connected to each other and equivalent.
-
Connect the cable terminal of channel 1 to the cable terminal 1 of the valve box.
-
Connect the cable terminal of channel 2 to the cable terminal 2 of the valve box.
Other channels can be connected similarly to the channels 1 and 2.
Cable cross-section of the connection cable:
The maximum permissible distance between the Watering Controller and the valve
depends on the cross-section of the connection cable. For a distance of 30 m,
the cross section is 0.5 mm2 and 0.75 mm2 for a distance of 45 m. No more
than 3 valves must be in operation at the same time.
The GARDENA connection cable Art. 1280 is 0.5 mm in size and is 15 m long. The
connection cable can be connected so that it is watertight using the cable
clip Art. 1282. 2
Mounting wall bracket:
V If using the expansion module 2040:
Hold the drilling template supplied against the wall and mark the holes with a
pen.
- Screw the mounting plate 8 for the watering controller (and, if applicable, the mountings for the expansion modules) to the wall.
- Hook the watering controller (with expansion module, if applicable) from above into the mounting plate 8 so that its back is against the mounting plate (and into the mountings for the expansion modules if applicable).
Operation
Setting the time format when using the equipment for the first time:
Time and Day of the Week
You must set the current time and day of the week before you can set the
watering programs.
Valves which are already open are closed automatically after one minute if the
time is changed.
-
Plug in the power supply unit (without battery).
TIME and 24 H flash in the display. -
Set 24 or 12 hour display with the ▲-▼ keys and confirm with the OK key.
TIME and the hours (e.g. 0) flash on the display.
Setting the time and day of the week:
-
Press TIME-Key.
-
Set the hour for the time using the ▲-▼ keys (e.g. 12 hours) and confirm your entry by pressing the OK key.
TIME and the minutes flash on the display. -
Set the minutes for the time using the ▲-▼ keys (e.g. 30 minutes) and confirm your entry by pressing the OK key.
TIME and the day of the week flash on the display. -
Set the day of the week using the ▲-▼ keys (e.g. FR Friday) and confirm your entry by pressing the OK key.
The time and the day of the week have been set.
Setting the watering programs:
Watering Programs
Prerequisite: you must set the current time and day of the week before
you can set the watering programs.
To give you a better overview of your irrigation system and to make it easier
to enter the watering data, we recommend entering the data for your valves on
the watering plan included in the appendix of these operating instructions. A
maximum of 6 channels can be open at the same time.
You can save 4 watering programs for each channel (a maximum of 4 programs x
12 channels = 48 programs).
If programs overlap, the channel status display flashes to indicate this and
ERROR (but the programs are still performed).
Make sure no programs overlap.
Selecting the Channel and Program Memory Location:
-
Press the Channel key for the relevant channel (e.g. Channel 2).
Channels (e.g. 2) appears in the display and program 1 flashes. -
Select the program memory location using the ▲-▼ keys (e.g. program memory location 3) and confirm your selection by pressing the OK key.
START TIME and the hours flash on the display.
Setting the Watering Start Time: -
Set the hours for the watering start time using the ▲-▼ keys (e.g. 16 hours) and confirm your entry by pressing the OK key.
START TIME and the minutes flash on the display. -
Set the minutes for the watering start time using the ▲-▼ keys (e.g. 30 minutes) and confirm your entry by pressing the OK key.
RUN TIME and hours flash on the display.
Setting the Watering Duration: -
Set the hours for watering duration using the ▲-▼ keys (e.g. 1 hour) and confirm you entry by pressing the OK key.
RUN TIME and minutes flash on the display. -
Set the minutes for watering duration using the ▲-▼ keys (e.g. 20 minutes) and confirm your entry by pressing the OK key.
The arrow êabove the watering cycle flashes on the display.
Setting the Watering Cycle:
(a) Every 2nd or 3rd day (from the current day)
(b) Select any day of the week (daily watering also possible with this setting) -
(a) Watering Cycle every 2nd or 3rd Day:
Using the ▲-▼ keys, set the arrow ê to 2nd or 3rd (e.g. 2nd = every 2nd day) and confirm your selection by pressing the OK key. The watering program is saved and the display shows the watering cycle (e.g. 2nd) and the preview for the week (e.g. Fr, Su, Tu, Th).
The days in the preview for the week are always with respect to the day of the week set in the system (e.g. Fr).
Set up more watering programs or return to the actual time using the Time key.
(b) Watering Cycle for Any Day of the Week:
Using the ▲-▼ keys, set the arrow ê to the desired day of the week (e.g. Mo = Monday) and select ■/ deselect the day by pressing the OK key.
When you have selected all the desired days of the week (e.g. Mo, We, Fr), press the ▲ key until the arrow ê over Su disappears.
The watering program is saved and the display shows the watering cycle (e.g. Mo, We, Fr).
Set up more watering programs or return to the actual time using the Time key.
% Run-Time-Funktion
Programmed watering periods
You must select the % Run-Time > 0 % you wish to activate before the watering
programs can run.
The times of all stored watering programmes can be reduced centrally in
intervals of 10%, from 200% down to 10%, without having to change each
interval programme. This is ideal if you wish to water your garden less in the
Autumn than in the Summer.
10 – 200 % Run-Time | Watering programs enabled |
---|---|
0 % Run-Time = Prog. Off | Watering programs disabled |
If the % Run-Time-function has been set to 0 % Run-Time (watering programs disabled), all the channels flash and the Prog. Off symbol appears in the normal display.
- Press % Run-Time key.
- Select required percentage for the programmed watering period with the ▲-▼ keys (e.g. 60 % Run-Time ) and confirm with the O.K. key.
The display moves to the actual time.
Programming the watering computer is now completed, i.e. the valves installed open/ close entirely automatically and therefore water at the programmed times. If the watering time is not equal to 100%, the % symbol appears in the display for the actual time.
Note: If you change the watering time percentage, your Water Computer will still display the watering time you originally programmed for the individual watering programs. When setting up/ modifying a program, this is automatically set to 100 % RunTime . The % Run-Time does not apply to manual watering.
Displaying the actual watering period:
The actual watering period is the percentage proportion of the programmed
watering period. E. g. if
The actual watering period is the percentage proportion of the programmed watering period. E. g. if 1 hour is set as the programmed watering period and 50 % Run-Time, the actual watering period of 30 minutes is displayed.
- Keep % Run-Time-button pressed and press the Channelbutton required
- Select program memory location with the ▲-▼ keys. All 48 programs can be selected one after the other with the ▲-▼ keys.
Changing an existing watering program:
You can change an existing program stored in one of the 4 program memory
locations without having to create the program from scratch.
The data for the watering starting time, duration, and cycle are preset;
therefore you only need to change the specific values of the watering program
you want to change. You can transfer all other values from “Setting the
Watering Program” by pressing the OK key.
Ending the programming mode prematurely:
You can exit the programming mode prematurely at any time.
Press the Time key.
The display shows the current time and day of the week.
Reset:
The Watering Controller is reset to the default setting and all program data
is deleted.
Keep Reset key pressed for 5 seconds.
- All symbols of the display light up for 2 seconds.
- The program data for all programs is deleted.
- The actual time and the day of the week are retained.
A reset can be triggered at any time. After this it is necessary to set the time (see 5. Operation “Setting the time and day of the week” ).
Manual Watering
Manual watering:
-
Press the Man key.
The manual display Man ■ appears and all the channels flash in the display. -
Press the relevant Channel key (e.g. channel 4).
RUN TIME and hours flash on the display. -
Press the Man key if you want to irrigate for 0 :30 minutes
– or –
set the manual watering duration using the ▲-▼ keys (e.g. 1 :15) and confirm your entry by pressing the OK key. Manual watering starts.
Water all channels manually:
When all the channels are to be enabled manually one after the other, it is
possible to do this using the Man. All key. During this process, all the
channels are opened manually one after the other corresponding to the manual
watering period.
Press the Man. All-key.
SPEC is displayed and watering starts with channel 1.
The Man. All key must be pressed to end watering prematurely.
Blocking channels
If watering is not necessary e.g. because of a relatively long period of rain,
all the channels can be blocked via the % Run Time function (see “ % Run-Time
function” ).
Individual channels can be blocked as follows:
-
Press and hold down the OK key and then press the relevant Channel key. (e.g. Channel 2).
The blocked channel and Prog. Off flash in the display. -
To reactivate the channel again, press and hold down the OK key and then press the relevant Channel key.
Tip: Should you have any questions about operating or programming your Watering Controller, please do not hesitate to contact your nearest GARDENA Service Centre. We will be happy to help you.
Trouble-Shooting
Replacing the fuse:
- Check battery status in the display and replace battery if necessary.
- Unplug the mains plug of the 24 V (AC) power supply unit.
- Raise cover 1 and pull downwards.
- Remove the fuse 0 and install a new fuse (2.5 A slow-blowing fuse).
- Push cover 1 on to the connection box.
- Plug the mains plug of the 24 V (AC) power supply unit into a 230 V mains socket.
Fault P | Possible Cause | Remedy |
---|---|---|
No display | External temperature below 0 °C or above +60 °C. | v Wait until the |
external air
temperature returns to the
operating temperature
range.
LCD display shows
ERROR FUSE| The fuse has blown.| 1. Check the wiring diagram
and /or determine the
cause.
2. Replace the fuse.
LCD display shows
ERROR noAC
(the programs are retained)| The power supply unit is not
plugged in.| v Plug the power supply unit
into a mains socket.
Valve cabling has a
short-circuit.| v Connect valve cables correctly
(see 4. Putting into Operation
“Connect valves” ).
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
authorised by GARDENA.
Putting Out of Operation
Wintering:| The watering controller is frost-proof down to –20°C.
No measures are required when frost commences.
v Check battery status display before the power supply unit is
disconnected.
---|---
Important:| Only dispose of batteries when they are flat.
v Return flat batteries to the place you bought them
or
dispose of them properly at your local recycling/disposal centre.
Disposal: (in accordance with RL2002 /96 /EC)| The product must not be added
to normal household waste. It
must be disposed of properly.
Technical Data
Power supply from power supply unit| 24 V (AC) 900 mA (sufficient for 6
GARDENA Watering Valves Art.1278)
---|---
Power supply for memory in case of
mains power failure:| Alkaline battery 9 V IEC 6LR61
Life of the battery:| At least 1 year (to retain data if there is a mains
failure)
Operating temperature range:| From 0°Cto+60°C
Temperature range for storage:| –20°C to +70°C
Air humidity:| 20 % to 95 % relative humidity
Soil moisture/rain sensor connection:| GARDENA-specific
Program saved when replacing battery:| Yes (if power supply unit connected)
Number of channels:| 4 channels and one master channel, with max. 4 expansion
modules Art.1277
enabling expansion to 12 channels and one master channel.
Number of program-controlled
watering cycles per channel:| Up to 4
Watering duration per program:| 1 minute to 4 h 59 min. (100 % Run-Time)
2 minutes to 9 h 58 min. (200 % Run-Time)
Service/Warranty
GARDENA guarantees this product for 2 years (from date of purchase). This guarantee covers all serious defects of the unit that can be proved to be material or manufacturing faults. Under warranty we will either replace the unit or repair it free of charge if the following conditions apply:
- The unit must have been handled properly and in keeping with the requirements of the operating instructions.
- Neither the purchaser or a non-authorised third party have attempted to repair the unit.
GARDENA will not replace Watering Controllers with defects resulting from
incorrect installation of the battery or leaking batteries.
This manufacturer’s guarantee does not affect the user’s existing warranty
claims against the dealer/seller.
If you have any problems with your watering controller, please contact our
Customer Service or return the defective unit together with a short
description of the problem directly to one of the GARDENA Service Centres
listed on the back of this leaflet.
Product Liability
We expressly point out that, in accordance with the product liability law, we
are not liable for any damage caused by our units if it is due to improper
repair or if parts exchanged are not original GARDENA parts or parts approved
by us, and, if the repairs were not carried out by a GARDENA Service Centre or
an authorised specialist. The same applies to spare parts and accessories.
Channel—–
Prog.| START TIME| RUN TIM| 3rd| 2nd| Mo|
Tu| We| Th| Fr| Sa| Su
---|---|---|---|---|---|---|---|---|---|---|---
1| | | | | | | | | | |
2| | | | | | | | | | |
3| | | | | | | | | | |
4| | | | | | | | | | |
Australia
Husqvarna Australia Pty. Ltd.
Locked Bag 5
Central Coast BC
NSW 2252
Phone: (+61) (0) 2 4352 7400
customer.service@husqvarna.com.au
New Zealand
Husqvarna New Zealand Ltd.
PO Box 76437
Manukau City 2241
Phone: (+64) (0) 9 9202410
support.nz@husqvarna.co.nz
1276-20.960.04/ 0311 © GARDENA
Manufacturing GmbH
D-89070 Ulm
http://www.gardena.com
References
- Anasayfa
- Outils de jardin GARDENA: tondeuses, arrosage, décoration de jardin
- Husqvarna Forest & Garden
- Husqvarna Australia | Tools & Equipment for Lawn, Garden and Forestry
- Husqvarna Magyarország
- 一瀬製作所 | ステンレス建具のプロフェッショナル■設計・製作・施工
- GARDENA - Garden tools - GARDENA
- Husqvarna Гора и Градина
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>