Heatit controls HeatitZ-Temp2 Z-Temp2 Manual
- June 8, 2024
- heatit CONTROLS
Table of Contents
- Heatit controls
- HeatitZ-Temp2
- SKU: Z-Temp2
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Temperature/ Humidity report interval
- Parameter 10: Temperature Control Hysteresis
- Parameter 11: Minimum Temperature Limit
- Parameter 12: Maximum Temperature Limit
- Parameter 13: External Relay & Operating State update interva
- Parameter 14: Report when presence is detected
- Parameter 2: Temperature delta value
- Parameter 3: Humidity delta value
- Parameter 4: Temperature offset settings
- Parameter 5: Humidity offset settings
- Parameter 6: Proximity sensor retrigger interval
- Parameter 7: Proximity sensorEnable / Disable
- Parameter 8: LED maximum brightness
- Parameter 9: LED turned on before timeout
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Heatit controls
HeatitZ-Temp2
SKU: Z-Temp2
Quickstart
This is a
secure
HVAC-Thermostat
for
.
Please make sure the internal battery is fully charged.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Heatit Z-Temp2 is a battery-operated thermostat designed for usewith water based heating systems. Used in combination with theHeatit Z-Water regulator you can control your heating system with aZ-Wave primary controller/gateway with the use of Heatit Z-Water incombination with one or several Heatit Z-Temp2.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Lifeline. Normally used by the Z-WaveController. |
---|---|---|
2 | 5 | Multilevel Sensor Report (internal measured temperate and measured |
relative humidity).
3| 5| Binary Switch Set (normally used to control external relays).
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Temperature/ Humidity report interval
Used to adjust the time between report interval for Temperature and humidity
reports.
Size: 2 Byte, Default Value: 900
SettingDescription
30 – 32767 | 30 to 32 767 seconds (Default 900) |
---|
Parameter 10: Temperature Control Hysteresis
Adjust the delta values for the thermostat to turn on off heating.
Size: 2 Byte, Default Value: 5
SettingDescription
3 – 30 | 0.3 to 3C (Default 5, 0,5C) |
---|
Parameter 11: Minimum Temperature Limit
Set the minimum temperature limit.
Size: 2 Byte, Default Value: 50
SettingDescription
50 – 400 | 5 to 40C (Default 50, 5C) |
---|
Parameter 12: Maximum Temperature Limit
Set the maximum temperature limit.
Size: 2 Byte, Default Value: 400
SettingDescription
50 – 400 | 5 to 40C (Default 400, 40C) |
---|
Parameter 13: External Relay & Operating State update interva
Set time on how often the devices sends Binary Switch Set and thermostat
mode to gateway.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Sends only when changed (Default) |
---|---|
1 – 240 | 1 to 240 minutes + When changed |
Parameter 14: Report when presence is detected
Decides if the thermostat sends temperature when presence is detected.
Size: 2 Byte, Default Value: 0
SettingDescription
0| Do not report to gateway when presence is detected, only at interval.
(Default)
---|---
1| Send temperature report to gateway when presence is detected.
Parameter 2: Temperature delta value
Temperature delta value.
Size: 2 Byte, Default Value: 10
SettingDescription
0 | Reporting temperate based on change is disabled |
---|---|
5 – 50 | 0.5 to 5C (Default 10, 1.0C) |
Parameter 3: Humidity delta value
Humidity delta value.
Size: 2 Byte, Default Value: 10
SettingDescription
0 | Reporting temperate based on change is disabled |
---|---|
5 – 50 | 5 to 50% (Default 10, 10%) |
Parameter 4: Temperature offset settings
Calibrate the internal sensor.
Size: 2 Byte, Default Value: 0
SettingDescription
-100 – 100 | -100 to 100C (Default 0, 0C) |
---|
Parameter 5: Humidity offset settings
Offsets the measured relative humidity.
Size: 2 Byte, Default Value: 0
SettingDescription
-100 – 100 | -10 to 10% (Default 0, 0%) |
---|
Parameter 6: Proximity sensor retrigger interval
Proximity sensor retrigger interval.
Size: 2 Byte, Default Value: 10
SettingDescription
2 – 270 | 2 to 270 seconds (Default 10, 10 seconds) |
---|
Parameter 7: Proximity sensorEnable / Disable
Choose if proximity sensor is used or not.
Size: 2 Byte, Default Value: 1
SettingDescription
0 | Disable |
---|---|
1 | Enable (Default) |
Parameter 8: LED maximum brightness
Adjust the backlight of LCD display.
Size: 2 Byte, Default Value: 50
SettingDescription
0 – 99 | 0 to 99% (Default 50, 50%) |
---|
Parameter 9: LED turned on before timeout
Adjust the time from proximity sensor / display touched until display goes
to sleep.
Size: 2 Byte, Default Value: 3
SettingDescription
3 – 300 | 3 to 300 secounds (Default 3, 3 seconds). |
---|
Technical Data
Hardware Platform | EFR32Z |
---|---|
Device Type | Thermostat – HVAC |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 1 FW: 1.01:00.02 |
Z-Wave Version | 7.11.1 |
Certification ID | ZC12-20050065 |
Z-Wave Product Id | 0x019B.0x0004.0x0204 |
Thermostat HVAC Systems Supported | Dual FuelHumidity ControlUniversal |
Thermostat Modes | Heat |
Color | White |
Thermostat Power Source | Battery |
Firmware Updatable | Updatable by Manufacturer |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Application Status
- Association Grp Info V3
- Association V2
- Basic V2
- Battery
- Configuration V4
- Device Reset Locally
- Firmware Update Md V5
- Indicator V3
- Manufacturer Specific V2
- Multi Channel Association V3
- Notification V8
- Powerlevel
- Protection
- Security
- Security 2
- Sensor Multilevel V5
- Supervision
- Thermostat Mode V3
- Thermostat Operating State
- Thermostat Setpoint V3
- Transport Service V2
- Version V3
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.