Zooz Z-Wave Relay Dimmer switch ZW34 Manual

June 8, 2024
ZOOZ

Table of Contents

Zooz

Z-Wave Relay Dimmer switch

SKU: ZW34

Quickstart

This is a
secure
Light Dimmer
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

This product is a Z-Wave multi-channel device.With dimming and relay two different functions. Built-in S2 security encryption

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Z-Wave Plus Lifeline
2 5 basic set command
3 5 basic set command

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: LED Indicator Mode for Dimmer

LED Indicator Mode for Dimmer
Size: 1 Byte, Default Value: 0

SettingDescription

0 On when off and off when on
1 On when on and off when off
2 Alwaysoff
3 Alwayson

Parameter 10: Auto Turn-Off Timer for Relay

Auto Turn-Off Timer for Relay
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 65535 The countdown time, the Relay off

Parameter 11: Auto Turn-On Timer for Relay

Auto Turn-On Timer for Relay
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 65535 The countdown time, the Relay on

Parameter 12: Restores state after power failure

Restores state after power failure
Size: 1 Byte, Default Value: 3

SettingDescription

0 dimmer, relay off
1 dimmer off, relay on
2 dimmer on, relay off
3 previous state for dimmer, previous state for relay
4 previous state for dimmer,relay on
5 previous state for dimmer,relay off
6 dimmer on, previous state for relay
7 dimmer off, previous state for relay
8 dimmer on, relay on

Parameter 13: Ramp rate

Ramp rate (local button only, remote control by command class)
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 99 from 0x63 to 0x00 or from 0x00 to 0x63 need Required time

Parameter 14: Multilevel minimum value can be set

Multilevel minimum value can be set
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 99 The minimum brightness of a dimmer

Parameter 15: Multilevel maximum value can be set

Multilevel maximum value can be set
Size: 1 Byte, Default Value: 99

SettingDescription

0 – 99 The maximum brightness of a dimmer

Parameter 17: when switch is on or off and quickly press UPPER paddle 2

times,

when switch is on or off and quickly press UPPER paddle 2 times, switch turns on to x brightness
Size: 1 Byte, Default Value: 0

SettingDescription

0 turn on to 99
1 turn on to the value relate with parameter 15

Parameter 18: Double Tap Behavior

Double Tap Behavior
Size: 1 Byte, Default Value: 0

SettingDescription

0| enable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23
---|---
1| disable double tap to full brightness, single tap to last brightness level or custom value set in parameter 23
2| isable double tap to full brightness, single tap always to full brightness

Parameter 19: Enable or Disable local / Z-Wave control for DIMMER

Enable or Disable local / Z-Wave control for DIMMER
Size: 1 Byte, Default Value: 1

SettingDescription

0 disable local on/off control
1 enable local and Z-Wave control (normal operation like now)
2 disable local and Z-Wave on/off control

Parameter 2: LED Indicator Mode for Relay

LED Indicator Mode for Relay
Size: 1 Byte, Default Value: 0

SettingDescription

0 On when off and off when on
1 On when on and off when off
2 Always off
3 Always on

Parameter 20: Enable or Disable local / Z-Wave control for RELAY

Enable or Disable local / Z-Wave control for RELAY
Size: 1 Byte, Default Value: 1

SettingDescription

0 disable local on/off control
1 enable local and Z-Wave control (normal operation like now)
2 disable local and Z-Wave on/off control

Parameter 21: Dimmer Speed Setting (only for local press & hold)

Dimmer Speed Setting (only for local press & hold)
Size: 1 Byte, Default Value: 4

SettingDescription

0 – 99 Time required for local key dimming

Parameter 22: Ramp rate for Z-Wave on/off controlled

Ramp rate for Z-Wave on/off controlled
Size: 1 Byte, Default Value: 0

SettingDescription

0 on/off ramp rate for Z-Wave same as manual control (set in Parameter 13)
1 on/off ramp rate for Z-Wave control set through command class (like now)

Parameter 23: default brightness level

Default brightness level – in this parameter define default brightness level
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 99 in this parameter define default brightness level

Parameter 3: LED Indicator Color for Dimmer

LED Indicator Color for Dimmer
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 4: LED Indicator Color for Relay

LED Indicator Color for Relay
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 5: LED Indicator Brightness for Dimmer

LED Indicator Brightness for Dimmer
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright(100%)
1 Medium(60%)
2 Low(30%)

Parameter 6: LED Indicator Brightness for Relay

LED Indicator Brightness for Relay
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 7: LED Indicator Mode for Scene

LED Indicator Mode for Scene
Size: 1 Byte, Default Value: 1

SettingDescription

0 Enable
1 Disable

Parameter 8: Auto Turn-Off Timer for Dimmer

Auto Turn-Off Timer for Dimmer
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 65535 The countdown time, the Dimmer Off

Parameter 9: Auto Turn-On Timer for Dimmer

Auto Turn-On Timer for Dimmer
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 65535 The countdown time, the dimmer on

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 2 FW: 1.00
Z-Wave Version 6.82.00
Certification ID ZC10-20016827
Z-Wave Product Id 0x0312.0xa000.0xa008
Switch Type Push Button
Electric Load Type Dimmable LEDFluorescentIncandescentInductive (e.g. Motor)
Firmware Updatable Updatable by Consumer by RF
Color White
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic V2
  • Central Scene V3
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Multi Channel Association V3
  • Multi Channel V4
  • Powerlevel
  • Security 2
  • Supervision
  • Switch Binary
  • Switch Multilevel V4
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>