JOYONWAY P16B162 Heat Pump Controller
Pre-use operations
- Please connect power strictly according to the power data plate.
- After connecting the load and checking it in detail, turn on the power and use it normally.
P168162 parameter
Input voltage: AC100-240V 50/60Hz Max. total load: 15.8A
Setting
Temperature setting
When the system is powered on, press” “till entering temperature setting interface. LCD will display with flash temperature unit. Press ” ” and ” “to set the temperature value. And setting range is 4~40’C(39~104’F). And system will store the set temperature value.
Clock setting
When the system is powered on, press” “till entering clock hour setting. LCD
will display the hour value with flash. Then press” “and” “to adjust the hour
value.
When the system is powered on, press” ” till entering clock minute setting.
LCD will display minute value with flash. The press” “and” “to adjust the
minute value.
Timing heat & cool time period setting (Economy mode and Sleeping mode only)
When system is powered on, press “ “till entering timing heating time period
setting interface. The correspondent time value will flash. Press “and” :
“to adjust the time.
“I”and “2”in LCD stand for time period 1 and time period 2. ” “and” “in LCD
stand for the starting and ending time of time period.The system will
automatically store the value after timing heating time period setting.
Timing water cycle time period setting
When system is powered on, press” ( ) “till entering timing water cycle time
period setting interface. The correspondent time value will flash. Press”
“and” “to adjust the time.
“1”and”2″in LCD stand for time period 1 and time period 2.” “and” ” in LCD
stand for the starting and ending time of time period.
The system will automatically store the value after timing water cycle time period setting.
Children lock protection setting
When the system is powered on, press constantly “ ” until it goes to children lock setting interface. Then press ” “to set the children lock function. When the setting is done, the system will save it.
Functions
Temperature unit
When the system is powered on and not in setting mode, press” “to switch the
temperature unit(°C or °F). The system will automatically store the value
after changing.
Working mode
AUX When the system is powered on and not in setting mode, press the key” ‘”
for 2 seconds to switch the working mode. The system has three working
modes(the system being powered is considered as standard mode by default):
- Standard mode (LCD displaying Model N ): heat & cool function will be valid in 24 hours. If system time falls in water cycle set time period, filtering water cycle function will be valid.
- Economy mode (LCD displaying Model E): if system time falls in water cycle set time period, filtering water cycle function is valid; if system time falls in heating set time period, heat & cool function will be valid. If system time is out of the set time period, freezing proof function will be started.
- Sleeping mode (LCD displaying Model D ): freezing proof will be started and other loads will be turned off and can not be controlled by keys.
Freezing proof
When water temperature is lower than 4°C (40°F) , heat will be started. When
the temperature reaches 9°C (48°F) , heat will be turned off.
Children lock (System with children lock protection)
If no button is touched within 3 minutes, then all the buttons will be locked,
and no operation can be done. At the same time, the LCD displays “LOC”; press
and hold any button for 3 seconds to unlock the panel. All the buttons work
and “LOC” disappears from the screen.
Light
When the control system is powered on and not in sleeping mode, or setting
mode, press the key” “to control light. Press the key” ” for 2 seconds to turn
off the light in short time.
Light has two modes. In on/ off mode, light turning on and off are controlled. In RGB mode, the control regulation is as below:
- state 1 auto color change (color changing among
- state 2 to state 8 in cycle) state 2 red
- state 3 green
- state 4 yellow
- state 5 blue
- state 6 purple
- state 7 cyan
- state 8 white
- state 9 turning off
Cycle Pump
When the control system is powered on and not in sleeping mode, or setting
mode, press the key” “to control the on/ off of cycle pump.
Cycle pump will turn off automatically after running for 30 minutes.
Timing water cycle
- When system works in standard and economy mode, timing water cycle is valid. In sleeping mode, timing water cycle is invalid.
- The control system has two water cycle setting time periods. Before usage, please set the two time periods.
- If the system time falls in either of the time periods, water cycle will be started. If the system time is in neither of the time periods, water cycle will be turned off.
Ozone
- Ozone will be turned off when pump, blower, water inflow or draining is started.
- When pump, blower, water inflow and draining are turned off and heating cycle pump or timing water cycle is started, ozone will be automatically started. When both heating cycle pump and timing water cycle are turned off, ozone will be turned off automatically.
Heat &Cool
- Heat & Cool function will be started automatically in standard mode. In economy mode, it will start in set time periods. In sleeping mode, freezing proof will work automatically.
- When heat & cool function is started, and water is detected(if system is equipped with water level sensing function), cycle pump will be started in ahead then heat pump will be started; if heat & cool is turned off, heat pump will turned off in ahead, then cycle pump will be turned off after a while.
- When heat & cool function is started, the system will start or stop the heat pump according to the water temperature and the set temperature, providing automatic control of the water temperature.
The temperature control laws (standard mode and economy mode) are as follows:
- If the water temperature is the set temperature + , the cooling function of the heat pump is activated;
- If the water temperature is the set temperature – , the heating function of the heat pump is activated;
- If water temperature = set temperature, stop the heat pump.
System malfunction table
Sun Hydraulics (China) Co.,Ltd. Dongguan Branch ADD: Room 302,Building 10,38 Dongke Road, Dongcheng Street, Donaauan citv. Guanadona Province
- TEL: +86 (755) 26010705 26010708
- Sale Tel: +86 (755) 26554068 26010859
- Oversea sales: (+86) 13925211653
- China sales: (+86) 13602626203
- FAX : +86 (755) 26010704 P.C.: 523749
- WEB : www.joyonway.com
- E-mail : sale1@joyonway.com
AFTER-SALES SERVICE
- China TEL: (+86) 13510031581
- Oversea TEL: (+86) 13510031501
- E-mail: service1@joyonway.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>