Zooz Z-WAVE PLUS ON / OFF LIGHT SWITCH ZEN21 VER 3.0 Manual
- June 8, 2024
- ZOOZ
Table of Contents
- Zooz
- Z-WAVE PLUS ON / OFF LIGHT SWITCH
- SKU: ZEN21 VER 3.0
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Paddle Control
- Parameter 10: Enable/Disable Paddle Control
- Parameter 2: LED Indicator Control
- Parameter 3: Enable / Disable Auto Turn-Off Timer
- Parameter 4: Set Auto Turn-Off Timer
- Parameter 5: Enable / Disable Auto Turn-Off Timer
- Parameter 6: Set Auto Turn-On Timer
- Parameter 8: On Off Status After Power Failure
- Parameter 9: Enable/Disable Scene Control
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Zooz
Z-WAVE PLUS ON / OFF LIGHT SWITCH
SKU: ZEN21 VER 3.0
Quickstart
This is a
secure
On/Off Power Switch
for
.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
PRODUCT HIGHLIGHTS:- Reliable on/off control for incandescent and LED lights- Unique Direct 3-Way Solution: no add-on switch needed (Neutral wire required)- Scene control (double tap as trigger)- Instant status reports- Advanced settings (built-in timer, LED indicator mode, paddle control, and more)PRODUCT SPECS:- Z-Wave Frequency: 908.42 MHz (US)- Power: 120 VAC, 60 Hz- Maximum Loads: 960W Incandescent, 150W LED and CFL bulbs, 1800W (15A) Resistive- Z-Wave Range: Up to 100 feet line of sight between the Wireless – Controller and the closest Z-Wave receiver module- Operating Temperature: 32-104 F (0-40 C)- Installation: Indoor use only
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | This device will send BASIC REPORT to Group 1 when operated manually. |
---|---|---|
2 | 5 | This device will send BASIC SET to group 2 when operated manually. |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Paddle Control
Choose if you want the upper paddle to turn the light on orturn the light
off when tapped.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 2| 0Upper paddle turns the light on, lower paddle turns the light off
(default); 1Upper paddle turns the light off, lower paddle turns the light on;
2Any paddle will turn light on / off depending on the status.
---|---
Parameter 10: Enable/Disable Paddle Control
Enable or disable local on/off control. If enabled, youll only be able to
control the connected light via Z-Wave. Scenes and other functionality will
still be available through paddles.
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 1 | 0local control disabled. 1local control enabled (default). |
---|
Parameter 2: LED Indicator Control
Choose if you want the LED indicator to turn on when theswitch (light) is on
or off, or if you want it to remain on or off at all times.
Size: 1 Byte, Default Value: 0
SettingDescription
0| LED indicator is on when switch is off, LED indicator is off when switch is
on (default)
---|---
1| LED indicator is on when switch is on, LED indicator is off when switch is
off
2| LED indicator is always OFF
3| LED indicator is always ON
Parameter 3: Enable / Disable Auto Turn-Off Timer
Use this parameter to enable or disable the auto turn-off timer function.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | 0timer disabled (default); 1timer enabled. |
---|
Parameter 4: Set Auto Turn-Off Timer
Use this parameter to set the time after which you want theswitch to
automatically turn off once it has been turned on. The number entered as value
corresponds to the number of minutes.
Size: 4 Byte, Default Value: 60
SettingDescription
1 – 65535 | minutes |
---|
Parameter 5: Enable / Disable Auto Turn-Off Timer
Use this parameter to enable or disable the auto turn-on timer function.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | 0timer disabled (default); 1timer enabled. |
---|
Parameter 6: Set Auto Turn-On Timer
Use this parameter to set the time after which you want theswitch to
automatically turn on once it has been turned off. The number entered as value
corresponds to the number of minutes.
Size: 4 Byte, Default Value: 60
SettingDescription
1 – 65535 | minutes |
---|
Parameter 8: On Off Status After Power Failure
Set the on off status for the switch after power failure.
Size: 1 Byte, Default Value: 2
SettingDescription
0 | 0forced to OFF (regardless of state prior to power outage) |
---|---|
1 | forced to ON |
2 | remembers and restores on/off status aer power failure (default) |
Parameter 9: Enable/Disable Scene Control
Enable or disable scene control functionality for quick double tap
triggers.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | 0scene control disabled (default). 1scene control enabled. |
---|
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.81.03 |
Certification ID | ZC10-19096759 |
Z-Wave Product Id | 0x027A.0xAA00.0xAA01 |
Z-Wave Scene Type | Central Scene |
Color | White |
Electric Load Type | FluorescentIncandescentLED |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Basic V2
- Central Scene V3
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Multi Channel Association V3
- Powerlevel
- Security 2
- Supervision
- Switch Binary
- Transport Service V2
- Version V3
- Zwaveplus Info V2
Controlled Command Classes
- Basic V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)