LEDone LOD-MWP HLV2 Series LED Mini Wall Pack, 25 Watt Installation Guide
- June 8, 2024
- LEDone
Table of Contents
LEDone LOD-MWP HLV2 Series LED Mini Wall Pack, 25 Watt
LOD-MWP HLV2 Series Installation Guide
SAFETY INSTRUCTIONS: Read instructions carefully before attempting to install fixture.
- All wiring should be performed by a qualified electrician.
- Disconnect power before installing or servicing. This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
- Proper grounding is required to ensure personal safety.
- This fixture is for outdoor use and should not be used in areas with limited ventilation or high ambient temperatures.
- If there is a problem with the fixture, turn off the power, but do NOT attempt repair unless you are a qualified technician.
- The electrical rating of this product contains a photocell that is 110-277VAC.
CAUTION: Risk of fire
- WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
CLEANING & MAINTENANCE
CAUTION: Be sure the fixture temperature is cool enough to touch. Do NOT clean or maintain while the fixture is energized.
- Clean glass lens with non-abrasive glass cleaning solution.
- Do NOT open fixture to clean the LED. Do NOT touch the LED.
Note: These instructions do not cover all details or variation in equipment, nor do they provide for every possible situation during installation, operation or maintenance.
TROUBLESHOOTING
- Check that the line voltage at fixture is correct. Refer to wiring directions.
- Check that the fixture is grounded properly.
WIRING: Universal voltage driver permits operation at 110V through 277V, 50/60Hz.
- Connect the BLACK fixture lead to the (+) LIVE line supply wire.
- Connect the WHITE fixture line to the NEUTRAL line supply wire.
- Connect the GREEN fixture line to the supply ground.
INSTALLATION
- Loosen screws to take the quick installation plate apart.
- Fix the quick installation plate to wall.
- Connect the incoming and outgoing wire.
- Install the fixture body to the quick installation plate and tighten the screws.
Phone: (844) LEDONE6 | Fax: 1-510-217-9461 | Web: www.ledonecorp.com