The Wiser radiator thermostat (hereinafter referred to as thermostat) uses integrated temperature sensors to control the flow of water through a radiator, thereby regulating the temperature in a room. The target temperature and switching times are set in the Wiser App.

Package contents

Schneider-Electric-CCTFR6100Z3-Wiser-Radiator-Thermostat-
FIG-1

  1. A Radiator Thermostat
  2. B O-ring (pre-installed)
  3. C Chrome ring nut
  4. D Danfoss RAVL
  5. E Danfoss RA
  6. F Danfoss RAV
  7. G M30 x 1.5 valve adapter
  8. H M4 hex nut
  9. I M4 x 11.5 mm screw
  10. J AA battery (pair)
  11. K Installation guide

Removing the old radiator thermostat

Schneider-Electric-CCTFR6100Z3-Wiser-Radiator-Thermostat-
FIG-2

Open the valve of the radiator thermostat to ‘max’ to facilitate removal. Unscrew ring nut and remove thermostat.

Note : For other manufacturers please follow their guidelines on how to remove the old radiator thermostats.

Inserting the batteries

  • When inserting batteries, observe the correct polarity.
  • Do not use rechargeable batteries.

QR Code label

TIP : The QR code is used for secured Zigbee commissioning which is an option in some Zigbee 3.0 systems. We strongly recommend not to remove this label in case future commissioning is required

Schneider-Electric-CCTFR6100Z3-Wiser-Radiator-Thermostat-
FIG-5

Install the adapter and thermostat

NOTICE
RISK OF DAMAGE TO EQUIPMENT

Schneider-Electric-CCTFR6100Z3-Wiser-Radiator-Thermostat-
FIG-4

  • Make sure that the O-ring is seated firmly on the thread.
  • Tighten the ring nut ensuring that the assembly is not overtightened. Failure to follow these instructions can result in equipment damage.

Follow the installation steps for the type of adapter you have

  1. M30 x 1.5mm adapter
  2. Place the M30 adapter on the valve.
  3. Loosely screw the ring nut onto the valve adapter.
  4. Screw on the thermostat and tighten.

Danfoss RAVL to M30 adapter

  1. Place the Danfoss RAVL on the valve.
  2. Place the M30 adapter on the Danfoss RAVL.
  3. Loosely screw the ring nut onto the valve adapter.
  4. Screw on the thermostat and tighten.

Danfoss RA to M30 adapter

  1. Place the Danfoss RA on the valve.
  2. Assemble M4 hex nut and M4 x 11.5 screw to tighten the Danfoss RA adapter onto the valve.
  3. Place the M30 adapter on the Danfoss RA.
  4. Loosely screw the ring nut onto the valve adapter.
  5. Screw on the thermostat and tighten.

Danfoss RAV to M30 adapter

  1. Break spindle adapter from the side of Danfoss RAV.
  2. Place spindle adapter on the top of the valve spindle and push fully on.
  3. Place the Danfoss RAV on the valve.
  4. Assemble M4 hex nut and M4 x 11.5 screw to tighten the Danfoss RA onto the valve.
  5. Place the M30 adapter on the Danfoss RAV.
  6. Loosely screw the ring nut onto the valve adapter.
  7. Screw on the thermostat and tighten.

NOTE : To align the LEDs in the desired position: slightly loosen the ring nut, turn the thermostat to the desired position and tighten the ring nut again.

Read full device guide online

Scan the QR code and choose your language for complete information about the device, including operation, configuration and using the product with a Wiser system.

Technical data

  • Power supply : 2x 1.5 V IEC LR6 (AA) alkaline batteries
  • Without power supply : Connection data retained
  • Temperature setting range : 5 °C to 30 °C
  • Temperature resolution : 0.5 °C
  • Control accuracy : < 0.8 °C at 4 °C/h
  • Surface temperature at place of installation : max. 93 °C
  • Water temperature: max. 110 °C, max. continuous 73 °C
  • Ambient operating temperature : 0 °C to 45 °C
  • Storage temperature:- 20 °C to 65 °C
  • Transportation temperature: -20 °C to 65 °C
  • Operating frequency : 2.4GHz
  • Max. radio frequency power transmitted : max. 20mW (13dBm)
  • Degree of contamination : 2
  • Radio range : 30 m free field
  • Energy class : IV – 2%
  • Software class : A Protection rating IP 30
  • Dimensions (HxØ): 93 x 51mm
  • Communication protocol : Zigbee 3.0 certified

Trademarks

  • Wiser™ is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliated companies.
  • Zigbee® is a registered trademark of the Connectivity Standard Alliance.

Other brands and registered trademarks are properties of their relevant owners

EU Declaration of Conformity

Hereby, Schneider Electric Industries, declares that this product is in compliance with the essential requirements and other relevant provisions of RADIO EQUIPMENT DIRECTIVE 2014/53/EU. Declaration of conformity can be downloaded on: se.com/docs.

Schneider Electric Industries SAS
If you have technical questions, please contact the Customer Care Centre in your country. se.com/contact

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals