devolo Devolo HC Switch FM MT 02759 Manual
- June 8, 2024
- devolo
Table of Contents
- devolo
- Devolo HC Switch FM
- SKU: MT 02759
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: In-wall Switch Type for Load 1 (Q) to control I1
- Parameter 10: Activate / deactivate ALL ON / ALL OFF Functionality
- Parameter 100: Enable / Disable Endpoint I2 or select the Notification
- Parameter 101: Enable / Disable Endpoint I3 or select the Notification
- Parameter 11: Turn Load 1 (Q) Off Automatically with Timer
- Parameter 110: Temperature Sensor Offset Settings
- Parameter 12: Turn Load 1 (Q) On Automatically with Timer
- Parameter 120: Temperature Sensor Reporting Threshold
- Parameter 15: Set Timer Units to Seconds or Milliseconds
- Parameter 2: Input 2 contact type
- Parameter 3: Input 3 contact type
- Parameter 30: Restore on/off status for Q load after power failure
- Parameter 40: Watt Power Consumption Reporting Threshold for Q Load
- Parameter 42: Watt Power Consumption Reporting Time Threshold for Q Load
- Parameter 63: Choose Normally Closed or Normally Open for Q Load
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
devolo
Devolo HC Switch FM
SKU: MT 02759
Quickstart
This is a
secure
On/Off Power Switch
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK1. Enable add/remove mode
on your Z-Wave gateway (hub)2. Connect the device to the power supply (with
the temperature sensor already connectedsold separately).3. Auto-inclusion
will be initiated within 5 seconds of connection to the power supply and the
device will automatically enroll in your networkMANUALLY ADDING THE DEVICE TO
A Z-WAVE NETWORK1. Enable add/remove mode on your Z-Wave gateway (hub)2.
Connect the device to the power supply (with the temperature sensor already
connected)3. Toggle the switch connected to the I1 terminal 3 times within 3
secondsORIf the device is powered by 24 V SELV supply, press and hold the S
(Service) button for at least 2 seconds4. A new multi-channel device will
appear on your dashboard*If connecting the temperature sensor, switch off the
power supply and make sure the device is excluded from your network BEFORE
connecting the sensor.Make sure the device is excluded from your network
before connecting the temperature sensor. Switch off the power supply, connect
the temperature sensor, and re-include the device to your network.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Devolo HC Switch FM controls on/off function for one electrical device. It measures power consumption of the connected device, and can be paired with a digital temperature sensor (sold separately). It supports push- button/momentary switches and toggle switches (default).The connection of a digital temperature sensor means you can create complex scenes and control any device relative to a set temperature range. The Devolo HC Switch FM also acts as a Z-Wave repeater to improve the range and stability of the Z-Wave network.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
FACTORY RESET Connect module to power supply bring module within maximum 1 meter (3 feet) of the main controller, enable add/remove mode on main controller press push button I1 five times within 5s (5 times change switch state within 5 seconds) in the first 60 seconds after the module is connected to the power supply or press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.By this function all parameters of the module are set to default values and own ID is deleted.*Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
AUTOMATICALLY ADDING THE DEVICE TO A Z-WAVE NETWORK1. Enable add/remove mode on your Z-Wave gateway (hub)2. Connect the device to the power supply (with the temperature sensor already connectedsold separately).3. Auto-inclusion will be initiated within 5 seconds of connection to the power supply and the device will automatically enroll in your networkMANUALLY ADDING THE DEVICE TO A Z-WAVE NETWORK1. Enable add/remove mode on your Z-Wave gateway (hub)2. Connect the device to the power supply (with the temperature sensor already connected)3. Toggle the switch connected to the I1 terminal 3 times within 3 secondsORIf the device is powered by 24 V SELV supply, press and hold the S (Service) button for at least 2 seconds4. A new multi-channel device will appear on your dashboard*If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor.Make sure the device is excluded from your network before connecting the temperature sensor. Switch off the power supply, connect the temperature sensor, and re-include the device to your network.
Exclusion
REMOVAL FROM A Z-WAVE NETWORK Connect module to power supply bring module within maximum 1 meter (3 feet) of the main controller, enable add/remove mode on main controllerIf push button I1 is pressed three times within 5s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Lifeline group (reserved for communication with the primary gateway
(hub)), 1 node allowed.
---|---|---
2| 16| Basic on/off (status change report for Q load), up to 16 nodes.
3| 16| Basic on/off (status change report for I2 input), up to 16 nodes.
4| 16| Notification report (status change report for I2 input), up to 16
nodes.
5| 16| Binary sensor report (status change of the I2 input), up to 16 nodes.
6| 16| Basic on/off (status change report for I3 input), up to 16 nodes.
7| 16| Notification report (status change report for I3 input), up to 16
nodes.
8| 16| Binary sensor report (status change of the I3 input), up to 16 nodes.
9| 16| Multilevel sensor report (triggered at change oftemperature sensor)
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: In-wall Switch Type for Load 1 (Q) to control I1
With this parameter, you can select between push-button (momentary) and
on/off toggle switch types.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | push-button (momentary) |
---|---|
1 | on/off toggle switch |
Parameter 10: Activate / deactivate ALL ON / ALL OFF Functionality
Devolo Relay device responds to commands ALL ON / ALL OF
Size: 2 Byte, Default Value: 255
SettingDescription
255 | ALL ON active, ALL OFF active |
---|---|
0 | ALL ON not active, ALL OFF not active |
1 | ALL ON not active, ALL OFF active |
2 | ALL ON active, ALL OFF not active |
Parameter 100: Enable / Disable Endpoint I2 or select the Notification
Type and the Notification Event
_Choose whether the Endpoint I2 is disabled (and not shown on the UI) or
enabled (and displayed on the UI). By enabling this endpoint (setting it to be
either a notification sensor or a binary sensor), the user also selects a
Notification Type and a Notification Event for which notification reports will
be sent (in case the endpoint is configured as a notification sensor).Endpoint
device type selection:-notification sensor (1 – 6):
GENERIC_TYPE_SENSOR_NOTIFICATION, SPECIFIC_TYPE_NOTIFICATION_SENSORsensor
binary (9): GENERIC_TYPE_SENSOR_BINARY, SPECIFIC_TYPE_NOTUSEDValues (size is
1 byte dec):NOTE 1: After changing the values of the parameter, first exclude
the device (without setting the parameters to their default values), then wait
at least 30 seconds to re-include the device!NOTE 2: When the parameter is set
to value 9 the notifications are sent for the Home Security notification
type.
Size: 1 Byte, Default Value: 0
SettingDescription
1 | Home Security; Motion Detection, unknown location |
---|---|
2 | CO; Carbon Monoxide detected, unknown location |
3 | CO2; Carbon Dioxide detected, unknown location |
4 | Water Alarm; Water Leak detected, unknown location |
5 | Heat Alarm; Overheat detected, unknown location |
6 | Smoke Alarm; Smoke detected, unknown location |
0 | Endpoint, I2 disabled |
9 | Sensor binary |
Parameter 101: Enable / Disable Endpoint I3 or select the Notification
Type and the Notification Event
_Choose whether the Endpoint I3 is disabled (and not shown on the UI) or
enabled (and displayed on the UI). By enabling this endpoint (setting it to be
either a notification sensor or a binary sensor), the user also selects a
Notification Type and a Notification Event for which notification reports will
be sent (in case the endpoint is configured as a notification sensor).Endpoint
device type selection:-notification sensor (1 – 6):
GENERIC_TYPE_SENSOR_NOTIFICATION, SPECIFIC_TYPE_NOTIFICATION_SENSOR-sensor
binary (9): GENERIC_TYPE_SENSOR_BINARY, SPECIFIC_TYPE_NOTUSEDNOTE 1: After
changing the values of the parameter, first exclude the device (without
setting the parameters to their default values), wait at least 30 seconds and
then re-include the device!NOTE 2: When the parameter is set to the value 9
the notifications are sent for the Home Security notification type.
Size: 1 Byte, Default Value: 0
SettingDescription
1 | Home Security; Motion Detection, unknown location |
---|---|
2 | CO; Carbon Monoxide detected, unknown location |
3 | CO2; Carbon Dioxide detected, unknown location |
4 | Water Alarm; Water Leak detected, unknown location |
5 | Heat Alarm; Overheat detected, unknown location |
6 | Smoke Alarm; Smoke detected, unknown location |
0 | Endpoint, I2 disabled |
9 | Sensor binary |
Parameter 11: Turn Load 1 (Q) Off Automatically with Timer
If Load 1 (Q) is ON, you can schedule it to turn OFF automatically after a
period of time defined in this parameter. The timer is reset to zero each time
the device receives an ON command, either remotely (from the gateway (hub) or
associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Auto OFF Disabled |
---|---|
1 – 32535 | 1 – 32535 seconds (or millisecondssee Parameter no. 15) Auto OFF |
timer enabled for a given amount of seconds (or milliseconds)
Parameter 110: Temperature Sensor Offset Settings
Set value is added to or subtracted from the actual measured value to adjust
the temperature report sent by an external sensor (sold separately). This
parameter only applies to Celcius temperature unit (the Fahrenheit unit is
currently not supported).
Size: 2 Byte, Default Value: 32536
SettingDescription
32536 | Offset is 0 degrees. |
---|---|
1 – 100 | Where 1 stands for 0.1 and 100 stands for 10.00 degrees added to the |
actual measurement
1001 – 1100| Where 1001 stands for -0.1 degrees and 1100 stands for -10.0
degrees subtracted from the actual measurement
Parameter 12: Turn Load 1 (Q) On Automatically with Timer
If Load (Q) is OFF, you can schedule it to turn ON automatically after a
period of time defined in this parameter. The timer is reset to zero each time
the device receives an OFF command, either remotely (from the gateway (hub) or
associated device) or locally from the switch.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | Auto ON Disabled |
---|---|
1 – 32535 | 1 – 32536 seconds (or millisecondssee Parameter no. 15) Auto ON |
timer enabled- for a given amount of seconds (or milliseconds).
Parameter 120: Temperature Sensor Reporting Threshold
If an external digital temperature sensor (sold separately) is connected to
the device, it reports temperature readings based on the threshold defined in
this parameter. This parameter only applies to the degrees temperature unit
(the Fahrenheit unit is currently not supported).
Size: 1 Byte, Default Value: 5
SettingDescription
5 | 0.5 degrees Celsius |
---|---|
0 | Reporting disabled |
1 – 127 | Where 1 stands for 0.1 and 127 stands for 12.7 degrees |
Parameter 15: Set Timer Units to Seconds or Milliseconds
Choose if you want to set the timer in seconds or milliseconds in parameters
11 and 12.Please note that the value for this parameter applies to settings
for Q load in all of the above parameters (timer on / timer off).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | timer set in seconds |
---|---|
1 | timer set in milliseconds |
Parameter 2: Input 2 contact type
With this parameter, input 2 contact type is defined.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | NO (normally open) input type |
---|---|
1 | NC (normally close) input type |
Parameter 3: Input 3 contact type
With this parameter, input 3 contact type is defined.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | NO (normally open) input type |
---|---|
1 | NC (normally close) input type |
Parameter 30: Restore on/off status for Q load after power failure
This parameter determines if on/off status is saved and restored for the
load Q after power failure.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | device saves last on/off status and restores it after a power failure. |
---|---|
1 | device does not save on/off status and does not restore it after a power |
failure, it remains off.
Parameter 40: Watt Power Consumption Reporting Threshold for Q Load
Choose by how much power consumption needs to increase or decrease to be
reported. Values correspond to percentages so if 10 is set (by default), the
device will report any power consumption changes of 10% or more compared to
the last reading.NOTE: Power consumption needs to increase or decrease by at
least 1 Watt to be reported, REGARDLESS of percentage set in this parameter.
Size: 1 Byte, Default Value: 10
SettingDescription
0 | Power consumption reporting disabled |
---|---|
1 – 100 | 1% – 100% Power consumption reporting enabled. New value is reported |
only when Wattage in real time changes by more than the percentage value set in this parameter compared to the previous Wattage reading, starting at 1% (the lowest value possible).
Parameter 42: Watt Power Consumption Reporting Time Threshold for Q Load
Set value refers to the time interval with which power consumption in Watts
is reported (032535 seconds). If 300 is entered (by default), energy
consumption reports will be sent to the gateway (hub) every 300 seconds (or 5
minutes).
Size: 2 Byte, Default Value: 300
SettingDescription
0 | Power consumption reporting disabled |
---|---|
1 – 32535 | 1 – 32535 seconds. Power consumption reporting enabled. Report is |
sent according to time interval (value) set here.
Parameter 63: Choose Normally Closed or Normally Open for Q Load
Set value determines the type of the device connected to the Q output. The
output type can be normally open (NO) or normally closed (NC).
Size: 1 Byte, Default Value: 0
SettingDescription
0 | When switch/device is off the output is 0V (NO). |
---|---|
1 | When switch/device is off the output is 230V (NC). |
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 6.05:06.05 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-18036057 |
Z-Wave Product Id | 0x0175.0x0002.0x0052 |
Supported Meter Type | Electric Energy |
Neutral Wire Required | ok |
Supported Notification Types | CO AlarmCO2 AlarmGas AlarmHeat AlarmHome |
SecurityPower ManagementSmoke AlarmWater Alarm
Color| White
Switch Type| Push Button
Sensors| Air Temperature
Electric Load Type| ELV (Electronic)IncandescentInductive (e.g. Motor)LED
Frequency| XXfrequency
Maximum transmission power| XXantenna
Supported Command Classes
- Association Grp Info V2
- Association V2
- Basic
- Device Reset Locally
- Manufacturer Specific V2
- Meter V4
- Multi Channel Association V3
- Multi Channel V4
- Notification V5
- Powerlevel
- Security
- Sensor Binary
- Sensor Multilevel V7
- Switch All
- Switch Binary
- Version V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.