Oomi Water Sensor FT122-B Manual
- June 8, 2024
- Oomi
Table of Contents
- Oomi
- Water Sensor
- SKU: FT122-B
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 10: Set the alarm time for the Buzzer when the sensor is
- Parameter 101: To set what unsolicited report would be sent to the
- Parameter 111: To set the interval time of sending reports in Report
- Parameter 135: To set which sensor report can be sent when the water leak
- Parameter 136: When the parameter 0x87 is set to 2 or 3, it can get the
- Parameter 2: Enable/Disable waking up for 10 minutes when re-power on
- Parameter 201: Temperature sensor calibration
- Parameter 252: Enable/disable all configuration parameters to be locked
- Parameter 255: Reset to factory defaults.
- Parameter 39: Configure the default low battery value.
- Parameter 48: Enable/disable the sensor report
- Parameter 49: Set the upper limit value (overheat).
- Parameter 50: Set the lower limit value (under heat)
- Parameter 57: Set the recover limit value of temperature sensor.
- Parameter 64: Set the default unit of the automatic temperature report in
- Parameter 8: Set the timeout of awake after the Wake Up CC is sent out..
- Parameter 84: Get the state of tilt sensor
- Parameter 86: Enable/ disable the buzzer.
- Parameter 87: To set which sensor is triggered the buzzer will alarm.
- Parameter 88: To set which value of the Basic Set will be sent to the
- Parameter 89: To set which value of the Basic Set will be sent to the
- Parameter 9: Report the current power mode and the product state for
- Parameter 94: To set which power source level is reported via the Battery
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Oomi
Water Sensor
SKU: FT122-B
Quickstart
This is a
secure
Alarm Sensor
for
Australia, NZL, Brasil, etc..
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press
the products Action Button that you can find on the product.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Oomi by Fantem Water Sensor brings intelligence to a new level, one that is suited to both safety and convenience. It contains 4 sensing points, which would be more accurately to detect the presence and absence of water or detect whether there is water leak in some places of your home. The Water Sensor has an inbuilt buzzer that can play alarm sounds to let you know when the water is detected.The Water Sensor is also a security Z-Wave device that supports Over The Air (OTA) for firmware updates.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press and hold the Action Button that you can find on the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find on the product.
Exclusion
Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action Button that you can find on the product.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Pressing the Action Button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the Water Sensor will wake up for 10 minutes.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| Lifelinegroup.1. The Battery Report or Multilevel Sensor Report
(Configurable) can be sent to the associated nodes in group 1.2. When the
water leak is detected, the Notification Report will be send to the associated
nodes in group 1.3. When the Water Sensor is reset, the Device Reset Locally
CC will be send to the associated nodes in group 1.
---|---|---
2| 5| Send the configuration parameter 0x88 to the associated nodes in group
2.
3| 5| Send Basic Set (configured by parameter 0x58) to the associated nodes in
Group 3 when the Sensor probe 1 is triggered.
4| 5| Send Basic Set (configured by parameter 0x59) to the associated nodes in
Group 4 when the Sensor probe 2 is triggered.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 10: Set the alarm time for the Buzzer when the sensor is
triggered.
Set the alarm time for the Buzzer when the sensor is triggered.
Size: 4 Byte, Default Value: 101968650
SettingDescription
1 – 255 | Repeated cycle of Buzzer alarm. |
---|---|
256 – 65535 | the time of Buzzer keeping ON state (MSB) |
65536 – 2147483647 | The time of Buzzer keeping OFF state |
Parameter 101: To set what unsolicited report would be sent to the
Lifeline group.
To set what unsolicited report would be sent to the Lifeline group.
Size: 1 Byte, Default Value: 3
SettingDescription
3 | Battery Report and Multilevel sensor report for temperature are enabled. |
---|---|
1 | Battery Report is enabled. |
0 | Send Nothing |
2 | Multilevel sensor report for temperature is enabled. |
Parameter 111: To set the interval time of sending reports in Report
group 1
To set the interval time of sending reports in Report group 1.Note:1. The
unit of interval time is second if USB power.2. If battery power, the minimum
interval time is equal to Wake Up interval set by the Wake Up CC.
Size: 4 Byte, Default Value: 3600
SettingDescription
5 – 2678400 | Available rang is 5 to 2678400 seconds. |
---|
Parameter 135: To set which sensor report can be sent when the water leak
event is triggered and if the receiving device is a non-multichannel device.
To set which sensor report can be sent when the water leak event is
triggered and if the receiving device is a non-multichannel device.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Send nothing |
---|---|
1 | Send notification report to association group 1. |
3 | Send notification report to association group 1 and Send configuration 0x88 |
report to association group 2.
2| Send configuration 0x88 report to association group 2.
Parameter 136: When the parameter 0x87 is set to 2 or 3, it can get the
sensor probes status through this configuration value.
When the parameter 0x87 is set to 2 or 3, it can get the sensor probes
status through this configuration value.Note: This parameter is a Get- only
parameter.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | absence of water is triggered by probe 1. |
---|---|
2 | presence of water is triggered by probe 2. |
1 | presence of water is triggered by probe 1. |
Parameter 2: Enable/Disable waking up for 10 minutes when re-power on
(battery mode) the MultiSensor.
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the
MultiSensor.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disable |
---|---|
1 | Enable. |
Parameter 201: Temperature sensor calibration
Temperature sensor calibration.Note:1.High byte is the calibration value.
Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit)2.The calibration value
(high byte) contains one decimal point. E.g. if the value is set to 20
(0x1400), the calibration value is 2.0(EU/AU version) or if the value is set
to 20 (0x1401), the calibration value is 2.0 (US version)3.The calibration
value (high byte) = standard value – measure value.E.g.If measure value =25.3
and the standard value = 23.2, so the calibration value= 23.2 – 25.3= -2.1
(0xEB).If the measure value =30.1 and the standard value = 33.2, so the
calibration value= 33.2 – 30.1=3.1 (0x1F).
Size: 2 Byte, Default Value: 1
SettingDescription
-128 – 127 | Available rang is -12.8 to 12.7. |
---|
Parameter 252: Enable/disable all configuration parameters to be locked
Enable/disable all configuration parameters to be locked.
Size: 1 Byte, Default Value: 0
SettingDescription
1 | Enable. |
---|---|
0 | Disable |
Parameter 255: Reset to factory defaults.
Reset to factory defaults.
Size: 4 Byte, Default Value: 0
SettingDescription
1431655765 | Reset the product to factory defaults. |
---|---|
1 | Reset all configuration parameters to factory defaults. |
Parameter 39: Configure the default low battery value.
Configure the default low battery value. When the current battery level is
lower than this value, it will send out the low battery alarm.
Size: 1 Byte, Default Value: 20
SettingDescription
10 – 50 | Available rang is 10% to 50%. |
---|
Parameter 48: Enable/disable the sensor report
Enable/disable the sensor report
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Disable |
---|---|
1 | Enable. |
Parameter 49: Set the upper limit value (overheat).
Set the upper limit value (overheat).
Size: 4 Byte, Default Value: 68157696
SettingDescription
0 | Celsius unit |
---|---|
1 | Fahrenheit unit |
65536 – 2147483647 | Temperature value |
Parameter 50: Set the lower limit value (under heat)
Set the lower limit value (under heat)
Size: 4 Byte, Default Value: 20971776
SettingDescription
0 | Celsius unit |
---|---|
1 | Fahrenheit unit |
65536 – 2147483647 | Temperature value |
Parameter 57: Set the recover limit value of temperature sensor.
Note:1. When the current measurement <= (Upper limitRecover limit), the
upper limit report is enabled and then it would send out a sensor report when
the next measurement is more than the upper limit. After that the upper limit
report would be disabled again until the measurement = (Lower limit + Recover
limit), the lower limit report is enabled and then it would send out a sensor
report when the next measurement is less than the lower limit. After that the
lower limit report would be disabled again until the measurement >= (Lower
limit + Recover limit).3. High byte is the recover limit value. Low byte is
the unit (0x01=Celsius, 0x02=Fahrenheit).
Size: 2 Byte, Default Value: 5121
SettingDescription
10 – 255 | Available rang is 1.0 to 25.5 |
---|
Parameter 64: Set the default unit of the automatic temperature report in
parameter 101-103.
Set the default unit of the automatic temperature report in parameter
101-103.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | The unit is Celsius. |
---|---|
1 | The unit is Fahrenheit. |
Parameter 8: Set the timeout of awake after the Wake Up CC is sent out..
Set the timeout of awake after the Wake Up CC is sent out..
Size: 1 Byte, Default Value: 30
SettingDescription
8 – 127 | Available rang is 8 to 127 seconds. |
---|
Parameter 84: Get the state of tilt sensor
Get the state of tilt sensor.Note: this is a Get-only parameter.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | The Water Sensor main unit is in horizontal direction. |
---|---|
1 | The Water Sensor main unit is in vertical direction. |
Parameter 86: Enable/ disable the buzzer.
Enable/ disable the buzzer.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Enable |
---|---|
0 | Disable |
Parameter 87: To set which sensor is triggered the buzzer will alarm.
To set which sensor is triggered the buzzer will alarm.
Size: 4 Byte, Default Value: 55
SettingDescription
32 | If the overheat is triggered, the buzzer will alarm. |
---|---|
1 | If the Water leak is triggered, the buzzer will alarm. |
2 | If the vibration is triggered, the buzzer will alarm. |
4 | If the tilt sensor is triggered, the buzzer will alarm. |
16 | If the under heat is triggered, the buzzer will alarm |
Parameter 88: To set which value of the Basic Set will be sent to the
associated nodes in association Group 3 when the Sensor probe 1 is triggered.
To set which value of the Basic Set will be sent to the associated nodes in
association Group 3 when the Sensor probe 1 is triggered.
Size: 1 Byte, Default Value: 0
SettingDescription
1| Presence of water, send Basic Set 0xFF, absence of water, send Basic Set
0x00.
---|---
2| Presence of water, send Basic Set 0x00, absence of water, send Basic Set
0xFF.
0| Send nothing
Parameter 89: To set which value of the Basic Set will be sent to the
associated nodes in association Group 4 when the Sensor probe 2 is triggered.
To set which value of the Basic Set will be sent to the associated nodes in
association Group 4 when the Sensor probe 2 is triggered.
Size: 1 Byte, Default Value: 0
SettingDescription
2| Presence of water, send Basic Set 0x00, absence of water, send Basic Set
0xFF.
---|---
0| Send nothing.
1| Presence of water, send Basic Set 0xFF, absence of water, send Basic Set =
0x00.
Parameter 9: Report the current power mode and the product state for
battery power mode
Report the current power mode and the product state for battery power
mode.Note: this parameter cannot be used as Set usage.
Size: 2 Byte, Default Value: 0
SettingDescription
257 | Keep awake for 10 minutes for battery power mode. |
---|---|
256 | Keep sleep state for Battery power mode |
0 | USB power mode |
Parameter 94: To set which power source level is reported via the Battery
CC.
To set which power source level is reported via the Battery CC.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | report the USB power level. |
---|---|
1 | report the CR123A battery level. |
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 122 FW: 1.01 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17065658 |
Z-Wave Product Id | 0x016A.0x0202.0x007A |
Firmware Updatable | Updatable by Consumer by RF |
IP (Ingress Protection) Rated | ok |
Sensors | Air TemperatureWater Flow |
Supported Notification Types | Heat AlarmHome SecurityWater Alarm |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V2
- Manufacturer Specific V2
- Multi Channel Association V3
- Multi Channel V4
- Notification V4
- Powerlevel
- Security
- Sensor Multilevel V5
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>