Nice On/Off-Control FGS-223 Manual

June 8, 2024
Nice

Table of Contents

Nice

On/Off-Control

SKU: FGS-223

Quickstart

This is a
secure
On/Off Power Switch
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

On/Off-Control is designed to be installed in standard wall switch boxes or anywhere else where it is necessary to control electric devices.On/Off-Control allows to control connected devices either via the Z-Wave Plus network or via a switch connected directly to it and is equipped with active power and energy consumption metering functionality

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| u0022Lifelineu0022 reports the device status and allows for assigning single device only (main controller by default).
---|---|---
2| 5| On/Off (S1) is assigned to S1 input terminal (uses Basic command class).
3| 5| u0022Dimmer (S1)u0022 is assigned to S1 input terminal (uses Switch Multilevel command class).
4| 5| On/Off (S2) is assigned to S2 input terminal (uses Basic command class).
5| 5| u0022Dimmer (S2)u0022 is assigned to S2 input terminal (uses Switch Multilevel command class).

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Restore state after power failure

This parameter determines if the device will return to state prior to the power failure after power is restored.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 1 Restore state after power failure

Parameter 10: Switch type

This parameter defines as what type the device should treat the switch connected to the S1 and S2 terminals.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 2 Switch type

Parameter 11: Flashing mode – reports

This parameter allows to define if the device sends reports during the flashing mode
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 1 Flashing mode – reports

Parameter 12: Associations in Z-Wave network security mode

This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. This parameter does not apply to 1st Lifeline group.Parameter 27 values may be combined, e.g. 1+2=3 means that 2nd and 3rd groups are sent as secure.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 15 Associations in Z-Wave network security mode

Parameter 13: S1 switch – scenes sent

This parameter determines which actions result in sending scene IDs assigned to them.Parameter 28 values may be combined, e.g. 1+2=3 means that scenes for single and double click are sent.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 15 S1 switch – scenes sent

Parameter 14: S2 switch – scenes sent

This parameter determines which actions result in sending scene IDs assigned to them.Parameter 29 values may be combined, e.g. 1+2=3 means that scenes for single and double click are sent.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 15 S2 switch – scenes sent

Parameter 15: S1 switch – associations sent to 2nd and 3rd association

groups

This parameter determines which actions are ignored when sending commands to devices associated in 2nd and 3rd association group. All actions are active by default.Parameter 30 values may be combined, e.g. 1+2=3 means that associations for turning ON and OFF are not sent.*Hold and release is inactive when parameter 20 is set to 1 or 2.**Double click is inactive when parameter 20 is set to 1.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 8 S1 switch – associations sent to 2nd and 3rd association groups

Parameter 16: S1 switch – Switch ON value sent to 2nd and 3rd association

groups

This parameter defines value sent with Switch ON command to devices associated in 2nd and 3rd association group.
Size: 2 Byte, Default Value: 255

SettingDescription

0 – 255 S1 switch – Switch ON value sent to 2nd and 3rd association groups

Parameter 17: S1 switch – Switch OFF value sent to 2nd and 3rd

association groups

This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 255 S1 switch – Switch OFF value sent to 2nd and 3rd association groups

Parameter 18: S1 switch – Double Click value sent to 2nd and 3rd

association groups

This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 255 S1 switch – Double Click value sent to 2nd and 3rd association groups

Parameter 19: S1 switch – Double Click value sent to 2nd and 3rd

association groups

This parameter defines value sent with Double Click command to devices associated in 2nd and 3rd association group.
Size: 2 Byte, Default Value: 99

SettingDescription

0 – 255 S1 switch – Double Click value sent to 2nd and 3rd association groups

Parameter 2: First channel – operating mode

This parameter allows to choose operating for the 1st channel controlled by the S1 switch.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 5 First channel – operating mode

Parameter 20: S2 switch – associations sent to 4th and 5th association

groups

his parameter determines which actions result in sending commands to devices associated in 4th and 5th association group. All actions are active by default. Parameter 35 values may be combined, e.g. 1+2=3 means that associations for turning ON and OFF are not sent.*Hold and release is inactive when parameter 20 is set to 1 or 2.**Double click is inactive when parameter 20 is set to 1
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 8 S2 switch – associations sent to 4th and 5th association groups

Parameter 21: S2 switch – Switch ON value sent to 4th and 5th association

groups

This parameter defines value sent with Switch ON command to devices associated in 4th and 5th association group.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 255 S2 switch – Switch ON value sent to 4th and 5th association groups

Parameter 22: S2 switch – Switch OFF value sent to 4th and 5th

association groups

This parameter defines value sent with Switch OFF command to devices associated in 4th and 5th association group.
Size: 2 Byte, Default Value: 0

SettingDescription

0 – 255 S2 switch – Switch OFF value sent to 4th and 5th association groups

Parameter 23: S2 switch – Double Click value sent to 4th and 5th

association groups

This parameter defines value sent with Double Click command to devices associated in 4th and 5th association group.
Size: 2 Byte, Default Value: 99

SettingDescription

0 – 255 S2 switch – Double Click value sent to 4th and 5th association groups

Parameter 24: Reaction to General Alarm

This parameter determines how the device will react to General Alarm frame.
Size: 1 Byte, Default Value: 3

SettingDescription

0 – 3 Reaction to General Alarm

Parameter 25: Reaction to Flood Alarm

This parameter determines how the device will react to Flood Alarm frame.
Size: 1 Byte, Default Value: 2

SettingDescription

0 – 3 Reaction to Flood Alarm

Parameter 26: Reaction to CO/CO2/Smoke Alarm

This parameter determines how the device will react to CO, CO2 or Smoke frame.
Size: 1 Byte, Default Value: 3

SettingDescription

0 – 3 Reaction to CO/CO2/Smoke Alarm

Parameter 27: Reaction to Heat Alarm

This parameter determines how the device will react to Heat Alarm frame.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 3 Reaction to Heat Alarm

Parameter 28: Flashing alarm duration

This parameter allows to set duration of flashing alarm mode.
Size: 2 Byte, Default Value: 600

SettingDescription

0 – 32000 Flashing alarm duration

Parameter 29: First channel – power reports

This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller.
Size: 1 Byte, Default Value: 20

SettingDescription

0 – 100 First channel – power reports

Parameter 3: First channel – reaction to switch for delay/auto ON/OFF

modes

This parameter determines how the device in timed mode reacts to pushing the switch connected to the S1 terminal.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 2 reaction to switch for delay/auto ON/OFF modes

Parameter 30: First channel – minimal time between power reports

This parameter determines minimum time that has to elapse before sending new power report to the main controller
Size: 1 Byte, Default Value: 10

SettingDescription

0 – 120 First channel – minimal time between power reports

Parameter 31: First channel – energy reports

This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller.
Size: 2 Byte, Default Value: 100

SettingDescription

0 – 32000 First channel – energy reports

Parameter 32: Second channel – power reports

This parameter determines the minimum change in consumed power that will result in sending new power report to the main controller.
Size: 1 Byte, Default Value: 20

SettingDescription

0 – 100 Second channel – power reports

Parameter 33: Second channel – minimal time between power reports

This parameter determines minimum time that has to elapse before sending new power report to the main controller.
Size: 1 Byte, Default Value: 10

SettingDescription

0 – 120 Second channel – minimal time between power reports

Parameter 34: Second channel – energy reports

This parameter determines the minimum change in consumed energy that will result in sending new energy report to the main controller.
Size: 2 Byte, Default Value: 100

SettingDescription

0 – 32000 Second channel – energy reports

Parameter 35: Periodic power reports

This parameter determines in what time interval the periodic power reports are sent to the main controller
Size: 2 Byte, Default Value: 3600

SettingDescription

0 – 32000 Periodic power reports

Parameter 36: Periodic energy reports

This parameter determines in what time interval the periodic energy reports are sent to the main controller.
Size: 2 Byte, Default Value: 3600

SettingDescription

0 – 3600 Periodic energy reports

Parameter 37: Measuring energy consumed by the device itself

This parameter determines whether energy metering should include the amount of energy consumed by the device itself. Results are being added to energy reports for first endpoint.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 1 Measuring energy consumed by the device itself

Parameter 4: First channel – time parameter for delay/auto ON/OFF modes

This parameter allows to set time parameter used in timed modes.
Size: 2 Byte, Default Value: 50

SettingDescription

0 – 32000 time parameter for delay/auto ON/OFF modes

Parameter 5: First channel – pulse time for flashing mode

This parameter allows to set time of switching to opposite state in flashing mode
Size: 2 Byte, Default Value: 5

SettingDescription

0 – 32000 pulse time for flashing mode

Parameter 6: Second channel – operating mode

This parameter allows to choose operating for the 1st channel controlled by the S2 switch.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 5 Second channel – operating mode

Parameter 7: Second channel – reaction to switch for delay/auto ON/OFF

modes

This parameter determines how the device in timed mode reacts to pushing the switch connected to the S2 terminal.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 2 Second channel – reaction to switch for delay/auto ON/OFF modes

Parameter 8: Second channel – time parameter for delay/auto ON/OFF modes

This parameter allows to set time parameter used in timed modes.
Size: 2 Byte, Default Value: 50

SettingDescription

0 – 32000 Second channel – time parameter for delay/auto ON/OFF modes

Parameter 9: Second channel – pulse time for flashing mode

This parameter allows to set time of switching to opposite state in flashing mode.
Size: 2 Byte, Default Value: 5

SettingDescription

1 – 32000 Second channel – pulse time for flashing mode

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 3 FW: 3.04
Z-Wave Version 6.51.07
Certification ID ZC10-22047084
Z-Wave Product Id 0x010F.0x0203.0x1000
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Application Status
  • Association Grp Info
  • Association V2
  • Basic
  • Switch Binary
  • Central Scene V2
  • Configuration
  • Crc 16 Encap
  • Device Reset Locally
  • Firmware Update Md V3
  • Manufacturer Specific V2
  • Meter V3
  • Multi Channel Association V3
  • Multi Channel V4
  • Notification V5
  • Powerlevel
  • Protection V2
  • Security
  • Version V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic
  • Notification V5
  • Switch Multilevel V3

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.