General information

For safety reasons, it is important to read all of the enclosed information ( Installation guide, Service manual, Spare parts, Operating instructions) before mounting this equipment. In addition, the legislation in force at the time of purchase must always be considered in connection with the installation and mounting of this equipment, no matter the contents of this manual. If there are matters of a dispute please contact your dealer.
This equipment is produced and tested by specially qualifi ed personnel, following approved instructions to ensure our high level of product quality. After the product is finished and tested it is manually inspected with the ultimate test carried out just before the product is released for shipping. To obtain our high level of quality and long life we use stainless steel parts. These parts, in defi ance of our manual inspections, may still have some sharp edges, which can present a cut hazard. Therefore it is advised always to use protective gloves and show caution when installing the equipment.

Preparation

If the wall is made of bricks or concrete, the enclosed screws and rawl plugs are usable otherwise you have to make sure that the carrying capacity of the wall is sufficlient.
Note: The pipeline must be rinsed through before the system is connected.
See service manual
Note: Remove cover before the system is mounted on the wall.

Placing/application

  • The satellite must be placed in frost-free rooms only.
  • Free space around the satellite: min 1000 mm.

Water supply

| SM3
---|---
Water volume| 30 l/min.
Pressure| 12-25 bar
Max. temperature| 70°C

The supply line must be sized so that it can supply the minimum indicated pressure and water volume when connected to this equipment.

Air supply

Air supply for the system is to meet the following specifi cations:

• Pressure 5 – 10 bar
• Consumption 200 Nl/min.

Piping

The pipe system should be made of stainless steel pipes. The pipe joints should be made in a way that makes separation possible in case of e.g. repairs, movement, or similar.

Pipe connections SM3
Water 1/2″ RG
Air 6 mm

Note: A 1/2” closing valve should be mounted on the water supply immediately before the satellite and dirt filter if any.

Assembly

Dimensions see fi g.1
It is recommended to mount the system at an appropriate height (approx. 1, 25 m above the floor) on a brick or concrete wall. Tighten the satellite with the enclosed screws and rawl plugs.

Type SM11 – SM33

Type SM1PD

© 2005 All rights reserved
Ecolab GmbH & Co. OHG
P.O. Box 13 04 06
D-40554 Düsseldorf
www.ecolab.com
Tel.: +49 211 98 93 203 – Fax: +49 211 98 93 223

Printed in Denmark

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals