Aeotec Heavy Duty Smart Switch Gen5 ZW078-A_Aeon_1406 Manual
- June 8, 2024
- Aeotec
Table of Contents
- Aeotec
- Heavy Duty Smart Switch Gen5
- SKU: ZW078-A_Aeon_1406
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Special Operations as Z-Wave Controller
- Configuration Parameters
- Parameter 100: Set parameter 101~103 to default.
- Parameter 101: to set which report need to be sent.
- Parameter 102: to set which report need to be sent.
- Parameter 103: to set which report need to be sent.
- Parameter 110: Set parameter 111~113 to default.
- Parameter 111: Set the interval time of sending report.
- Parameter 112: Set the interval time of sending report.
- Parameter 113: Set the interval time of sending report.
- Parameter 200: PartnerID
- Parameter 252: Enable/Disable Lock Configuration
- Parameter 255: Reset to default factory setting
- Parameter 3: Current Overload Protection
- Parameter 80: Enable/Disable to send notifications to associated devices
- Parameter 90: Enable/Disable the function of parameter 91 and 92
- Parameter 91: Induce an automatic report
- Parameter 92: Induce an automatic report
- Technical Data
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aeotec
Heavy Duty Smart Switch Gen5
SKU: ZW078-A_Aeon_1406
Quickstart
This is a ****
On/Off Power Switch
for
U.S. / Canada / Mexico.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
N/A
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Aeon Labs Heavy Duty Smart Switch is a Z-Wave device that can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway), it can be controlled by other Z-Wave devices to turn on/off loads, it can bear up to 40A current of resister loads. It also acts as a repeater that forward Z-Wave command messages to destination nodes if the originating controller is out of range from the destination node.By taking advantage of the Z-Wave mesh network, commands can be routed to their destination via intermediary listening Z-Wave products. Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press and hold the Z-Wave button for 20 seconds and then release.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
N/A
Exclusion
N/A
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
N/A
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| Group 1 is assigned to the Lifeline association group and every device
has 5 nodes to associate.
---|---|---
2| 5| When the Heavy Duty Smart Switch Gen5 receives the following commands,
it will forward the commands to all node IDs (in Group 2).The command will be
sent via multicast (if there are more than 2 Node IDs) or single-cast (if
there is only one Node ID). Commands: Basic Set, Switch Binary Set, Scene
Activation Set.
Special Operations as Z-Wave Controller
As long as this device is not included into a Z-Wave network of a different
controller
it is able to manage its own Z-Wave network as primary controller. As a
primary controller
the device can include and exclude other devices in its own network, manage
associations,
and reorganize the network in case of problems. The following controller
functions
are supported:
Inclusion of other devices
Communication between two Z-Wave devices only works if both belong to the same
wireless network. Joining a network is called inclusion and is initiated by a
controller.
The controller needs to be turned into the inclusion mode. Once in this
inclusion mode
the other device needs to confirm the inclusion – typically by pressing a
button.
If current primary controller in your network is in special SIS mode this and
any other secondary controller can also include and exclude devices.
To become
primary a contoller have to be resetted and then include a device.
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button.
Exclusion of other devices
The primary controller can exclude devices from the Z-Wave network. During
exclusion
the relationship between the device and the network of this controller is
terminated.
No communication between the device and other devices still in the network can
happen
after a successful exclusion. The controller needs to be turned into the
exclusion mode.
Once in this exclusion mode the other device needs to confirm the exclusion –
typically
by pressing a button.
Attention: Removing a device from the network means that it is turned
back
into factory default status. This process can also exclude devices from it’s
previous
network.
Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 100: Set parameter 101~103 to default.
This parameter is used to restore the parameter 101, 102 and 103 to default
setting.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1| When value==1, parameters 101 ~103 will be restored to default
setting.When value==0, it will not restore any parameter.
---|---
Parameter 101: to set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report
Group 1 (The possible values as below).
Size: 4 Byte, Default Value: 4
SettingDescription
0 – 15| When value==1, which means the Voltage report is configured to be sent
in Report Group 1. When value==2, which means the Current report is configured
to be sent in Report Group 1. When value==4, which means the Wattage report is
configured to be sent in Report Group 1. When value==8, which means the KWH
report is configured to be sent in Report Group 1. When value==15, which means
the Voltage , Current , Wattageand KWH report are all configured to be sent in
Report Group 1. The other values will be reserved.
---|---
Parameter 102: to set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report
Group 2 (The possible values as below).
Size: 4 Byte, Default Value: 8
SettingDescription
0 – 15| When value==1, which means the Voltage report is configured to be sent
in Report Group 2. When value==2, which means the Current report is configured
to be sent in Report Group 2. When value==4, which means the Wattage report is
configured to be sent in Report Group 2. When value==8, which means the KWH
report is configured to be sent in Report Group 2. When value==15, which means
the Voltage , Current , Wattageand KWH report are all configured to be sent in
Report Group 2. The other values will be reserved.
---|---
Parameter 103: to set which report need to be sent.
This parameter is used to configure which reports need to be sent in Report
Group 3 (The possible values as below).
Size: 4 Byte, Default Value: 0
SettingDescription
0 – 15| When value==1, which means the Voltage report is configured to be sent
in Report Group 3. When value==2, which means the Current report is configured
to be sent in Report Group 3. When value==4, which means the Wattage report is
configured to be sent in Report Group 3. When value==8, which means the KWH
report is configured to be sent in Report Group 2. When value==15, which means
the Voltage , Current , Wattageand KWH report are all configured to be sent in
Report Group 3. The other values will be reserved.
---|---
Parameter 110: Set parameter 111~113 to default.
This parameter is used to restore the parameter 111, 112 and 113 to default
setting.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | When value==1, parameters 111 ~113 will be restored to default setting. |
---|
Parameter 111: Set the interval time of sending report.
This parameter is used to set the interval time of sending report in Report
Group 1.(The unit of time is second).
Size: 4 Byte, Default Value: 5
SettingDescription
0 – 268435456| You have a wide range to set the interval time that can be set
from 0 to 268435456 seconds.
---|---
Parameter 112: Set the interval time of sending report.
This parameter is used to set the interval time of sending report in Report
Group 2.(The unit of time is second).
Size: 4 Byte, Default Value: 120
SettingDescription
0 – 268435456| You have a wide range to set the interval time that can be set
from 0 to 268435456 seconds.
---|---
Parameter 113: Set the interval time of sending report.
This parameter is used to set the interval time of sending report in Report
Group 3.(The unit of time is second).
Size: 4 Byte, Default Value: 120
SettingDescription
0 – 268435456| You have a wide range to set the interval time that can be set
from 0 to 268435456 seconds.
---|---
Parameter 200: PartnerID
This parameter is used to configure the partner ID.0== Aeon Labs Standard
Product,1~255== others.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 255 | There are 255 different partners can be configured. |
---|
Parameter 252: Enable/Disable Lock Configuration
This parameter is used to Enable/Disable Lock all configuration
parameters.(0 =disable, 1 = enable)
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1| When value==0, all configuration parameters are configurable. When
value==1, all configuration parameters are not configurable.(Locked).
---|---
Parameter 255: Reset to default factory setting
This parameter is used to reset product to default factory setting.(There
are just 2 values can be used)
Size: 4 Byte, Default Value: 0
SettingDescription
0 – 1431655765| When value==1431655765, it will reset the product to default
factory setting and be excluded from Z-wave network. When value==1, it only
will reset the all configuration parameters to default setting. The other
values will be reserved.
---|---
Parameter 3: Current Overload Protection
This parameter is used for the overload protection, which means the load
will be disconnected after 5 seconds when the current more than 39.5A.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | 0=disabled, 1=enabled |
---|
Parameter 80: Enable/Disable to send notifications to associated devices
to associated devices
This parameter is used to Enable/Disable to send notifications to associated
devices (in Group 1) when the state of Heavy Duty Smart Switch Gen5s load is
changed. (0=send nothing, 1=send hail CC, 2=send basic CC report).
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 2 | (0=nothing, 1=hail CC, 2=basic CC report |
---|
Parameter 90: Enable/Disable the function of parameter 91 and 92
This parameter is used to Enable/Disable the function of parameter 91 and 92
below (1=Enabled, 0=Disabled).
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 1 | 0=disabled, 1=enabled |
---|
Parameter 91: Induce an automatic report
This parameter is used to induce an automatic report when the change of the
current power is more/less than the threshold in wattage.
Size: 2 Byte, Default Value: 50
SettingDescription
0 – 60000 | The threshold can be set from 0 to 60000 watt. |
---|
Parameter 92: Induce an automatic report
This parameter is used to induce an automatic report when the change of the
current power is more/less than the threshold in percentage.
Size: 1 Byte, Default Value: 10
SettingDescription
0 – 100 | The threshold can be set from 0 to 100 percent. |
---|
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 78 FW: 3.26 |
Z-Wave Version | 6.51.00 |
Certification ID | ZC10-14060004 |
Z-Wave Product Id | 0x0086.0x0103.0x004E |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Controlled Command Classes
- Basic
- Hail
- Scene Activation
- Switch Binary
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>