Popp Z-Wave Wall Plug Switch Type F POP_123610 Manual
- June 8, 2024
- POPP
Table of Contents
- Popp
- Z-Wave Wall Plug Switch Type F
- SKU: POP_123610
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Popp
Z-Wave Wall Plug Switch Type F
SKU: POP_123610
Quickstart
This is a ****
On/Off Power Switch
for
Russia.
To run this device please connect it to your mains power supply.
Inclusion and Exclusion are confirmed by a tripple click of the button.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This is a switch plug that can be placed between a standard (Type F) wall outlet and electric devices, plugged in by cord. It can switch all electrical loads up to 3500 W. The device is IP 20 rated and can therefore only be used on dry environments. Switching is controlled wirelessly using Z-Wave or locally using a toggleing button. A blue LED indicates the switching status. An automatic “Off” function and programmable switching behavior make the device a very flexible tool for the inhouse lighting.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
The plug can be plugged into every wall outlet for Plug-Type F. It is IP20 rated and can therefore only be used in dry environments. Do not locate the device facing direct sunlight, humid or dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C. Plugs must not be stacked and operated.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Inclusion and Exclusion are confirmed by a tripple click on the button.
Exclusion
Inclusion and Exclusion are confirmed by a tripple click on the button.
Product Usage
The device is able to switch electric loads up to 3500 W and can be switched wirelessly or using the local button.
Local Operation
The local button allowes to switch the device. A short press on the button
toggles the switch. If it is in on state the button turns off and respective
in off state the button turns on.
LED Usage
The device has one blue LED used to indicate status information. The behavior
of the blue LED can be configured:
- It may show the switching state. This is the default option.
- It may serve as night light. So it is on when the light is off.
- It is deactivated.
- It can be controlled wirelessly and used as an indicator for other advanced functions.
Automated Switch-Off Function
If activated the switch will turn off automatically after a defined time. This
function is particularly useful if the switch is turned on using a motion
detector of any other type of sensor. In this case it is possible to further
define the reaction of the switch on certain signals sent from a sensor. This
allowes a very flexible application of the plug switch in the house.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Send Reports on switch state change |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: LED mode
Set LED indication mode
Size: 1 Byte, Default Value: 01
SettingDescription
00 | Disabled |
---|---|
01 | Show switch state |
02 | Night mode (inverted switch state) |
03 | Operated by Indicator Command Class |
Parameter 2: Automatically switch off after
If not zero, automatically switch off after a user defined time
Size: 2 Byte, Default Value: 0000
SettingDescription
0000 | Disabled |
---|---|
0001 – ffff | sec |
Parameter 3: What to do on RF off command
Defines how to interpret RF Off command. Can be used in conjunction with
Auto Off function: Ignore – to switch on the light by motion detectors and
switch it off after some amount of time: in case of multiple motion detectors
each would try to switch the light off that would break logics; Switch on – to
switch on the light on both On and Off paddle press on the remote and switch
it off after some amount of time. Button off click will still work (if button
operations are not disabled).
Size: 1 Byte, Default Value: 00
SettingDescription
00 | Switch off |
---|---|
01 | Ignore |
02 | Switch on |
03 | Switch on if load is off else switch off |
Parameter 5: Restore switch state after power cycle
Defines if the switch should restore switch state to the last state prior to
device power off (power cycle).
Size: 1 Byte, Default Value: 01
SettingDescription
00 | No, turn off |
---|---|
01 | Yes |
Technical Data
Dimensions | 0.0600000×0.1020000×0.0750000 mm |
---|---|
Weight | 123 gr |
EAN | 696859123610 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 01.00 |
Z-Wave Version | 03.2a |
Certification ID | ZC08-13070027 |
Z-Wave Product Id | 0115.1100.0001 |
Frequency | Russia – 868.4MHz, 869.85MHz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Basic
- Switch Binary
- Version
- Indicator
- Switch All
- Configuration
- Manufacturer Specific
- Protection
- Node Naming
- Association
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>