- Configuration Parameters
- Parameter 1: Always On Function
- Parameter 16: Remember device status after power failure
- Parameter 34: Reaction to Alarm
- Parameter 35: Response to Alarm Frames
- Parameter 39: Alarm duration
- Parameter 40: Immediate Power Report
- Parameter 42: Standard Power Load Reporting
- Parameter 43: Power Reporting Frequency
- Parameter 45: Reporting Changes in energy consumed by controlled devices
- Parameter 47: Time Period between reports on power and energy consumption
- Parameter 49: Metering Energy consumed by Power Plug itself
- Parameter 50: DOWN value
- Parameter 51: UP value
- Parameter 52: Action in case of exceeding defined power values (Parameter
- Parameter 60: Power Load Trigger
- Parameter 61: LED Ring Color when device is on
- Parameter 62: LED Ring Color when device is off
- Parameter 63: LED Ring Color on Z-Wave Alarms
- Parameter 70: Overload Safety Switch
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fibaro Group
Wall Plug with Metering Function Type E
SKU: FIB_FGWPE-101
Quickstart
This is a ****
On/Off Power Switch
for
Europe.
To run this device please connect it to your mains power supply.
The inclusion of the device is confirmed by a tripple click on the button. Additionally the device supports the autoinclusion function and will confirm inclusion when not manually included and plugged into an outlet. A red light on the LED ring confirms inclusion. The exclusion follows the same process but is recommended to use the Reset function to remove devices from the network.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Fibar plug with power metering function is a very compact stylish and intelligent remotely operable plug for wall outlets of Type E. It can be applied to switch loads up to 2500 W and will meter the acutal and accumulated power consumption of this load. A LED ring right on the device is used to indicate switching and power load stages or general alarm conditions, but can not be tuned up to all colors of the LED spectrum.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
To reset the plug and delete all settings, plug the device into the outlet and keep the button on the devices pushed for about 15…20 seconds until the LED ring starts to shine yellow. Now release the button and tip the button again shortly. The LED lights red to confirm the reset.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
The plug can be plugged into every wall outlet for Plug-Type E. It is IP20 rated and can therefore only be used in dry environments. Do not locate the device facing direct sunlight, humid or dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C. Plugs must not be stacked and operated.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
The inclusion of the device is confirmed by a tripple click on the button. Additionally the device supports the autoinclusion function and will confirm inclusion when not manually included and plugged into an outlet. A red light on the LED ring confirms inclusion. The exclusion follows the same process but is recommended to use the Reset function to remove devices from the network.
Exclusion
The inclusion of the device is confirmed by a tripple click on the button. Additionally the device supports the autoinclusion function and will confirm inclusion when not manually included and plugged into an outlet. A red light on the LED ring confirms inclusion. The exclusion follows the same process but is recommended to use the Reset function to remove devices from the network.
Product Usage
The device is operared by the little button on the device or by wireless Z-Wave commands. The function of the LED ring can be defined using configuration parameters. It is possible to signal overcurrent or general alarm conditions of the Z-Wave network. In parallel the device indicates with purple light, when the ambient temperature exceeds 55 °C.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
3 | 1 | reports relais status to one device |
---|---|---|
2 | 5 | send commands depending on current load |
1 | 5 | plug status. Will send BASIC command whenever the status of the plug |
changes
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Always On Function
Once activated, Wall Plug will keep a connected device constantly ON, will
stop reacting to alarm frames and B-button push
Size: 1 Byte, Default Value: 01
SettingDescription
00 | active |
---|---|
01 | inactive |
Parameter 16: Remember device status after power failure
Define how will the Plug react after the power supply is back on
Size: 1 Byte, Default Value: 01
SettingDescription
00| Wall Plug does not memorize its state after a power failure. Connected
device will be off after the power supply is reconnected
---|---
01| Wall Plug memorizes its state after a power failure
Parameter 34: Reaction to Alarm
defines the alarm types the plug reacts to. Set value may be a sum of
available values, e.g. set value = 5 means the Plug will respond to general
alarm (1) and CO alarm (4).
Size: 1 Byte, Default Value: 3f
SettingDescription
Parameter 35: Response to Alarm Frames
defines the response of the plug to an alarm. In always on mode this setting
is ignored.
Size: 1 Byte, Default Value: 00
SettingDescription
00 | No Reaction |
---|---|
01 | Turn on connected device, LED ring signals alarm through time set in |
Parameter 39 or until alarm is turned off
02| Turn off connected device, LED ring signals alarm through time set in
Parameter 39 or until alarm is turned off
03| Change Device state every second. In alarm mode the plug does not report
status changes, power changes and ignores alarm frames. After alarm time
(Parameter 39) has passed or alarm was canceled device is set back to previous
state
Parameter 39: Alarm duration
Wall Plugs alarm mode duration. If a device sending an alarm frame through
the Z-Wave network sets alarm duration as well, this parameters settings are
ignored.
Size: 2 Byte, Default Value: 0258
SettingDescription
Parameter 40: Immediate Power Report
Parameter defines by how much power load must change, in percents, to be
reported to the main controller, with the highest priority in the Z-Wave
network. By default, Fibaro Wall Plug immediately sends power report if the
power load changes by 80%. NOTE: In extreme cases, reports may be sent every
second if rapid and significant power load changes occur. Frequent reporting
may overload the Z-Wave network so these parameters settings should reflect
significant changes in power load only.
Size: 1 Byte, Default Value: 50
SettingDescription
Parameter 42: Standard Power Load Reporting
defines the change in power consumption to cause an unsolicided power
report
Size: 1 Byte, Default Value: 0f
SettingDescription
Parameter 43: Power Reporting Frequency
defines the frequency to send an unsolicided power report
Size: 1 Byte, Default Value: 1e
SettingDescription
01 – fe | Define a frequency to send reports. |
---|---|
ff | Reports will be sent only as a result of parameter 47 settings or in case |
of polling
Parameter 45: Reporting Changes in energy consumed by controlled devices
defines needed change of power draw to generate an unsoliceded power report
Size: 1 Byte, Default Value: 10
SettingDescription
01 – fe | Define a value. Available settings: 1 – 254 (0,01kWh – 2,54kWh). |
---|---|
ff | Changes in consumed energy will not be reported. Reports will be sent only |
in case of polling.
Parameter 47: Time Period between reports on power and energy consumption
defines the time pweriod between reports sent when changes in power load
have nit been reported.
Size: 2 Byte, Default Value: 0e10
SettingDescription
0001 – fffe | Define a time interval. |
---|---|
ffff | No periodic reports. Reports will be sent only in case of power load / |
energy consumption changes (parameters 40,42,43,45) or in case of polling.
Parameter 49: Metering Energy consumed by Power Plug itself
defines whether or not the own power consumption shall be recorded.
Size: 1 Byte, Default Value: 00
SettingDescription
00 | inactive |
---|---|
01 | active |
Parameter 50: DOWN value
Lower power threshold, used in parameter 52 (value cannot be higher than a
value specified in parameter 51)
Size: 2 Byte, Default Value: 012c
SettingDescription
Parameter 51: UP value
Upper power threshold, used in parameter 52 (value cannot be lower than a
value specified in parameter 50)
Size: 2 Byte, Default Value: 01f4
SettingDescription
Parameter 52: Action in case of exceeding defined power values (Parameter
50/51)
definies the action for devices in association group 2 when power trigger
value is reached.
Size: 1 Byte, Default Value: 06
SettingDescription
00 | inactive |
---|---|
01 | turns associated devices ON when when power drops below DOWN value |
02 | turns associated devices OFF when when power drops below DOWN value |
03 | turns associated devices ON when when power drops below UP value |
04 | turns associated devices OFF when when power drops below UP value |
05 | Option 1 and 4 combined |
06 | Option 2 and 3 combined |
Parameter 60: Power Load Trigger
defines the power load that will make the plug flash purple (only when
parameter 61 is set to 0 or 1)
Size: 2 Byte, Default Value: 61a8
SettingDescription
Parameter 61: LED Ring Color when device is on
defines the color of the LED ring in ON state
Size: 1 Byte, Default Value: 01
SettingDescription
00 | changes in predefined steps according to power load |
---|---|
01 | changes continously according to power load using full spectrum of LED |
color
02| White
03| Red
04| Green
05| Blue
06| Yellow
07| Cyan
08| Magenta
09| Off
Parameter 62: LED Ring Color when device is off
defines the color of the LED ring in OFF state
Size: 1 Byte, Default Value: 01
SettingDescription
00| LED ring is illuminated with a color corresponding to the last measured
power, before the controlled device was turned off
---|---
01| White
02| Red
03| Green
04| Blue
05| Yellow
06| Cyan
07| Magenta
08| Off
Parameter 63: LED Ring Color on Z-Wave Alarms
defines the color of the LED ring on Alarm State
Size: 1 Byte, Default Value: 01
SettingDescription
00 | No Change of color |
---|---|
01 | flashes red/blue/white |
02 | White |
03 | Red |
04 | Green |
05 | Blue |
06 | Yellow |
07 | Cyan |
08 | Magenta |
09 | Off |
Parameter 70: Overload Safety Switch
Allows turning off a device in case of overloading. This will even happen in
always on mode. Device can be turned back on using the button on the device or
sending a ON command.
Size: 2 Byte, Default Value: ffff
SettingDescription
Technical Data
Dimensions | 0.0430000×0.0430000×0.0650000 mm |
---|---|
Weight | 55 gr |
EAN | 5902020528128 |
Device Type | On/Off Power Switch |
Generic Device Class | Binary Switch |
Specific Device Class | Binary Power Switch |
Firmware Version | 16.16 |
Z-Wave Version | 03.34 |
Certification ID | ZC08-14020004 |
Z-Wave Product Id | 010f.0600.1000 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Basic
- Association
- Version
- Alarm
- Manufacturer Specific
- Configuration
- Sensor Multilevel
- Meter
- Powerlevel
- Firmware Update Md
- Sensor Alarm
- Switch Binary
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)