ABUS ABUS Z-Wave Waterleak Detector ABUESHWM10000 Manual
- June 8, 2024
- ABUS
Table of Contents
- ABUS
- ABUS Z-Wave Waterleak Detector
- SKU: ABUESHWM10000
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Quick trouble shooting
- Association – one device controls an other device
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ABUS
ABUS Z-Wave Waterleak Detector
SKU: ABUESHWM10000
Quickstart
This is a
secure
Alarm Sensor
for
Europe.
To run this device please insert fresh *1 CR2** batteries.
Please make sure the internal battery is fully charged.
A.) Slide the base unit from the mounting plate and remove the safety strip
from the battery compartment.
B.) Click the + (Add) button in your Z-Wave App and follow the further
instructions
C.) Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on
the base unit front will flash 3 times. T
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The ABUS Z-Wave Waterleak Detector protects reliably against water damage by detecting liquids. The detector is Ideal for monitoring cellars, washing machines, and drains. The water level sensor can be flexible installed due to 120cm cable length.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press and hold the tamper button while inserting the battery.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Mount the base unit to the wall by using the adhesive strip
Place the sensor contact on a flat surface on the floor in the vicinity of the most likely sources of leaks
The Detector is triggered as soon as the two sensor tips come into contact with moisture
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
A.) Slide the base unit from the mounting plate and remove the safety strip
from the battery compartment.
B.) Click the + (Add) button in your Z-Wave App and follow the further
instructions
C.) Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on
the base unit front will flash 3 times.
Exclusion
A.) Click the – (Remove) button in your Z-Wave App and follow the further
instructions.
B.) Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on
the base unit front will flash 3 times.
Product Usage
1. Sensor
2. LED Indicator
3. Leak detector
4. Tamper
5. Battery Case
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Lifeline |
---|---|---|
2 | 5 | Sensor – Binary Sensor |
3 | 5 | Tamper – Binary Sensor |
4 | 5 | Sensor – Notification Report |
5 | 5 | Tamper – Notification Report |
Technical Data
Dimensions | 0.0270000×0.0720000×0.0200000 mm |
---|---|
Weight | 35 gr |
Hardware Platform | ZM5101 |
EAN | 4003318841521 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR2 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18116319 |
Z-Wave Product Id | 0x0403.0x0002.0x0002 |
Color | White |
Communications Protocol | Z-Wave Serial API |
Sensors | Water Flow |
Supported Notification Types | Water Alarm |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Device Reset Locally
- Manufacturer Specific V2
- Multi Channel Association V3
- Notification V8
- Powerlevel
- Security 2
- Supervision
- Transport Service V2
- Version V3
- Wake Up V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>