DUCO Roof Turret Solid 30Z Instructions

June 8, 2024
Duco

DUCO Roof Turret Solid 30Z

Dimension

DUCO-Roof-Turret-Solid-30Z-fig- \(1\)

Fitting

DUCO-Roof-Turret-Solid-30Z-fig- \(2\)

DUCO-Roof-Turret-Solid-30Z-fig- \(3\)

Single module installation

DUCO-Roof-Turret-Solid-30Z-fig- \(4\)

  • A swell band (supplied) fits between the roof Turret & concrete base (E0001601). Glue this to the roof Turret OR the base.
    • Drill holes around the roof Turret, through the flange in the concrete. The holes must be large enough for M8 bolts.
    • Not more than 1000 mm between the holes and at least 2 per side.

Secure the threaded end in the concrete structure (e.g.: chemical anchoring injection mortar

Secure the Roof Turret with nut and washer (not supplied by Duco)

Installation of multiple modules

DUCO-Roof-Turret-Solid-30Z-fig- \(7\)

  • A swell band (supplied) fits between the roof Turret & concrete base (E0001601). Glue this to the roof Turret OR the base.

  • If option DG Close 105:
    There has to be a swell band (E0001601) on the open side as well, at the bottom of the roof turret on the side of the profile

  • Drill holes around the roof Turret, through the flange in the concrete. The holes must be large enough for M8 bolts.

  • Not more than 1000 mm between the holes and at least 2 per side.

Secure the threaded end in the concrete structure (e.g.: chemical anchoring injection mortar

Secure the Roof Turret with nut and washer

If no intermediate modules: Skip this step

  • If option DG Close 105:
    There has to be a swellband (E0001601) on the open side as well, at the bottom of the Roof Turret on the side of the profile.

  • A swellband (supplied) fits between Roof Turret & concrete base (E0001601). Glue this to the Roof Turret OR the base.

  • Make sure that the Roof Turret modules connect properly

  • Drill holes around the Roof Turret, through the flange in the concrete. The holes must be large enough for M8 bolts.

  • Not more than 1000 mm between the holes and at least 2 per side.DUCO-Roof-Turret-Solid-30Z-fig- \(10\)

Secure the threaded end in the concrete structure (e.g.: chemical anchoring injection mortar

Secure the Roof Turret with nut and washer

DUCO-Roof-Turret-Solid-30Z-fig- \(13\)

  • A swellband (supplied) fits between Roof Turret & concrete base (E0001601). Glue this to the Roof Turret OR the base.
  • Make sure that the Roof Turret modules connect properly
  • Drill holes around the Roof Turret, through the flange in the concrete. The holes must be large enough for M8 bolts.
  • Not more than 1000 mm between the holes and at least 2 per side.

Secure the threaded end in the concrete structure (e.g.: chemical anchoring injection mortar

Secure the Roof Turret with nut and washerDUCO-Roof-Turret-Solid-30Z-fig-
\(15\)

Provide coupling plate (G012007) with double-sided tape (E0001612)DUCO-Roof-
Turret-Solid-30Z-fig- \(16\)

Screw the slat to the Roof Turret using self drilling screw Ø4,8×16 (G0000227)

  • Seal the seams on the corner pieces with silicone
  • Seal the seams between the drainage profiles with siliconeDUCO-Roof-Turret-Solid-30Z-fig- \(17\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals