System INSTRUCTIONS FOR USE
Instructions For Use
Intended Use
The Flexineb is a portable equine nebuliser system intended to aerosolize veterinarian prescribed ® liquid solutions into a fine mist for inhalation into the airways of the horse. The end user is liable for the safe operation of the Flexineb ® and its parts as outlined in the Instructions for Use. Medications must be prescribed by a veterinarian and end users should follow the advice of their veterinarian at all times.
Safety Information
When using the Flexineb ® for the first time remember it is the first time for
the horse too so caution is advised. Softly place the Flexineb ® over the
horses’ nose and mouth with the bottom exit valve open so the horse can
breathe normally. Push up until the nostrils are covered and a seal is made
around the nose and mouth. Once the horse is breathing normally and is getting
used to the Flexineb ® , shut the bottom valve by twisting the exit valve and
commence treatment. If the horse is resisting the
mask be patient and let them look at it and smell it before attempting to fit
the mask again. If the horse starts to get scared during treatment, slightly
open the exit valve so more air is being inhaled. Close the valve again once
the horse is relaxed.
In an emergency situation the exit valve on the bottom of the mask can be
pulled out to allow the horse breathe freely. Although the mask material is
soft and flexible the front aerosol chamber and battery controller is hard
plastic therefore caregivers should be mindful of the risk posed by the horse
shaking its head with the Flexineb
® fitted.
Instructions for Use
Flexineb Nebuliser (Fig. 1 ):
- Please read the Intended Use, Safety Information and Maintenance sections before using Flexineb
- Check Inlet and Exit Valves are moving freely before placing the Mask on the horse
- Rotate and open the Vent at bottom of Mask to allow the horse become familiar with the device
- Fill the Medication Cup strictly following advice of your veterinarian
- Close the vent in the bottom of the Mask when the horse is familiar with the Mask
- Switch on the Controller and nebulisation will begin after a few seconds
- You will see the Aerosol Chamber fill with aerosol and empty when the horse inhales
- The Controller will time out after approximately 35 minutes or it can be switched off manually
- To re-charge the battery only use the Flexineb supplied charger
Flexineb MDI Use (Fig. 2):
- Remove the Controller, Cable and Medication Cup
- Plug the supplied Adaptor into the Inlet Valve on top of the Aerosol Chamber
- Rotate the Aerosol Chamber to the horizontal position
- Insert the MDI and administer medication following the advice of your veterinarian
Controller Functions
Technical Information
Flow Rate: Typically :?:1.0 ml/min with 0.9% NaCl solution. The flow rate
is very dependent on the drug used.
Aerosol Droplet Size: Flexineb generates aerosol droplets in the
respirable range for delivery to the airways of the horse.
The aerosol droplet size is dependent on the drug used.
Medication Cup Volume: The medication cup will hold 10ml of liquid but is
expandable to 30ml using the plug in extension cup supplied. The controller
has a timer function therefore, if the extension cup is used the controller
will need to be re-started to complete the dose.
Battery Power: Battery Type: 7.4V Li-ion rechargeable battery. Use the
Flexineb supplied battery only. Use of another type of battery may present a
risk of fire or explosion.
Operating Time: ~ 6 hours from fully charged.
Battery Charging: Use the Flexineb supplied charger only. Use of an
alternative charger may present a risk of fire or explosion. A fully
discharged battery can take 4 to 5 hours to reach full charge. Mains Power
Supply: (Input: 100 to 240v AC / 50 to 60 Hz)
The Flexineb can also be operated using the Power Supply provided with the
system. The same Power Supply charges the battery. Use the Flexineb Power
Supply only.
Use of an alternative Power Supply may present a risk of fire or explosion and
void warranty.
Environmental Conditions:
Operating: 5 ° ° C to 45 C and up to 95% RH Storage and
Transportation: -20 ° ° C to +45 C and 15% to 95% RH
Troubleshooting
Refer to www.flexineb.com website for detailed
information on troubleshooting Flexineb problems.
Maintenance/ Cleaning
Medication Cup: Do Not use ‘Well Water’ & Do Not Place in Dishwasher.
Cleaning: It is very important to wash out the Med Cup after each use to avoid
contamination or damage of the metallic vibrating mesh. Protect the electrical
connector from getting wet when cleaning by using the protective cap provided.
To clean out the Med Cup open up the soft blue Cap and place 2-3 drops of mild
dish-washing liquid (do not use dishwasher detergent) into the Cup and fill
with distilled water. Close the soft blue Cap and shake the Cup vigorously for
about 15 seconds and squeeze the soft Cap to push water through the mesh
whilst shaking. Open the Cap and rinse out from both sides with distilled
water. Shake off excess water and let air dry before re-use.
Disinfection: To disinfect the outside surfaces of the Med Cup use anti-
bacterial wipes.
CAUTION:
Do not immerse the Med Cup in water or cleaning chemical solutions!
Do not nebulize or put chemical cleaning solutions inside the Cup as they may
permanently damage the metallic mesh or reduce its life!
Do not use sharp instruments to clean the metallic mesh in the Med Cup!
For continuity of treatment it is highly recommended to carry spare Med Cups!
Mask: Cleaning: The Mask can be washed using clean warm tap water with some
dish washing up liquid.
Rinse off with warm clean tap water and dry off before re-use.
Disinfection: First disassemble all parts of the Mask and wash them thoroughly
with clean warm tap water and dish washing up liquid. Rinse the parts off and
let them air dry on a clean dry surface.
Disinfect each part by wiping down thoroughly with anti-bacterial wipes before
re-assembly.
Alternatively the Mask parts can be soaked in Nortev approved disinfectant
chemicals.
Refer to separate information sheet or
www.flexineb.com for details on recommended
disinfectants.
Check www.flexineb.com for updates and video
instructions on Cleaning & Disinfecting Flexineb.
Controller: To maintain the function of the electronic controller it must be
used and stored in dry conditions.
To maintain the battery function it must be charged when the Battery LED turns
Red.
CAUTION:
Do not immerse the controller in water or any liquid as this will permanently
damage the electronics!
Warranty
Mask Assembly (excluding valves) , Controller (excluding battery) and Cable,
Power Supply (charger): 24 months. Battery: 6 months. The Medication Cup is a
wearing part and its life is very dependent on drugs nebulised and how well it
is maintained therefore it is not covered by warranty.
Damage caused by improper handling or misuse is not covered by warranty.
Use of an alternative Power Supply may present a risk of fire or explosion and
void warranty.
Compliance
Flexineb complies with the essential requirements of all relevant European
Directives and Harmonized Standards.
Nortev Limited, Unit 14, Westlink Commercial Park, Oranmore, Galway, Ireland
Contact us: Nortev Ltd
Unit 14 Westlink Commercial Park Oranmore Galway Ireland
+353 (0) 91 79 97 78
General Enquiries: info@nortev.com
Technical Support:
technicalsupport@nortev.com
Website: www.flexineb.com
Follow us on our Social Media
Channels to keep up to date with all the latest on Flexineb!
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>