Breville LWA100 the AquaStation Purifier User Manual
- June 4, 2024
- Breville
Table of Contents
Breville LWA100 the AquaStation Purifier User Manual
BREVILLE RECOMMENDS SAFETY FIRST
At Breville we are very safety conscious. We design and manufacture consumer products with the safety of you, our valued customer, foremost in mind. In addition, we ask that you exercise a degree of care when using any electrical appliance and adhere to the following precautions. Misuse can cause potential injuries.
MAIN TECHNICAL SPECIFICATIONS
Tested against: NSF/ANSI Standard 42 for the reduction of chlorine (taste and odour), & NSF/ANSI 372, lead content.
Tested to remove/reduce microplastics, floating particles/sediment, pesticides, chlorine, limescale & heavy metals.
Testing was performed under standard laboratory conditions. The contaminants or other substances removed or reduced by this filter are not necessarily in all users’ water. Filter performance may vary based on local water conditions.
IMPORTANT SAFEGUARDS
READ ALL INSTRUCTIONS BEFORE USE AND SAVE FOR FUTURE REFERENCE
- Carefully read all instructions before operating and save for future reference.
- Remove and safely discard any packaging material and promotional labels before using the AquaStation™ Purifier for the first time.
- Always ensure the appliance is properly assembled before use. Follow the instructions provided in this book.
- The AquaStation™ Purifier must be used only with the Breville filter supplied or replacement product code LWA063.
- This appliance has been designed specifically for the purpose of filtering drinking quality water only. Under no circumstances should this appliance be used to heat any other liquids.
- Do not place the appliance near the edge of a bench or table during operation. Ensure that the surface is level, clean and free of water and other substances.
- Do not operate the appliance on a sink drain board.
- Never immerse the appliance, power cord or power plug in water, or allow moisture to come into contact with these parts.
- Do not move the appliance while it is switched on.
- Always ensure the appliance returns to standby mode, then turn the power off at the power outlet and remove the power plug from the power outlet before attempting to move the appliance, when the appliance is not in use and before cleaning and storing.
- Do not remove the water tank from the power base during operation.
- If the water tank is removed from the power base during water dispensing, the appliance will automatically stop.
- Always fill the water tank with water between the minimum (MIN) and maximum (MAX) as marked on the water tank.
- Too little water will result in the appliance not operating and the Fill Tank indicator water drop icon will turn red. Filling above the maximum mark (MAX) may result in water splashing from the water tank.
- Ensure the water level is always above the MIN level for optimum dispensing flow rate.
- The lid should always be correctly fitted on the water tank except when refilling.
- Do not place the appliance in direct sunlight. Colour fading and discolouration may occur when the appliance is consistently exposed to sunlight.
- This appliance is intended to filter tap water only. Do not put water of unknown quality into the appliance. Use only cold or room temperature water.
- Do not fill the water tank with hot water. Water added to the water tank should not be less than 5°C or more than 40°C. If water in the tank is outside these temperatures, discard and fill with cold tap water.
- Do not leave the appliance unattended during operation.
- Do not remove filter while the appliance is operating.
⚠ WARNING
- Do not operate the appliance on an inclined plane. Do not move appliance unless the appliance is turned off and unplugged from the power outlet.
- Keep the appliance and all parts clean. Follow the cleaning instructions provided in this book.
- Any procedure not listed in this instruction book should be performed at an authorised Breville Service Centre.
IMPORTANT SAFEGUARDS FOR ALL ELECTRICAL APPLIANCES
-
Fully unwind the power cord before use.
-
Connect only to a 230V or 240V power outlet.
-
The appliance must be used on a properly grounded outlet. If you are not sure, please consult a qualified electrician.
-
Do not, under any circumstances, modify the power plug or use a power plug adapter.
-
Do not place this appliance on or near a heat source, such as a hot plate, oven or heaters.
-
Position the appliance at a minimum distance of 20cm away from walls, curtains and other heat or steam sensitive materials and provide adequate space above and on all sides for air circulation.
-
Do not let the power cord hang over the edge of a bench or table, touch hot surfaces or become knotted. Keep away from hot gas or electric burners, or where it could touch a heated oven.
-
This appliance is for household use only. Do not use this appliance for anything other than its intended use. Do not use in moving vehicles or boats. Do not use outdoors. Misuse may cause injury.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
-
Children should be supervised to ensure that they do not play with the appliance.
-
Always turn the appliance to the OFF position, switch off at the power outlet and unplug at the power outlet when the appliance is not in use.
-
Before cleaning, always turn the appliance to the OFF position,
switch off at the power outlet, unplug at the power outlet and remove the power cord, if detachable, from the appliance and allow all parts to cool. -
To protect against electric shock, do not immerse the power cord, power plug or appliance in water or any other liquid or allow moisture to come in contact with the parts, unless it is recommended in the cleaning instructions.
-
Any maintenance other than cleaning should be performed at an authorised Breville Service Centre
-
It is recommended to regularly inspect the appliance. To avoid a hazard, do not use the appliance if power cord, power plug or appliance becomes damaged in any way. Return the entire appliance to the nearest authorized Breville Service Centre for examination and/or repair.
-
The installation of a residual current device (safety switch) is recommended to provide additional safety protection when using electrical appliances. It is advisable that a safety switch with a rated residual operating current not exceeding 30mA be installed in the electrical circuit supplying the appliance. See a qualified electrician for professional advice.
-
During electrical storms, the appliance should be disconnected from the power source at the wall socket to prevent any electrical surges that may arise during the storm and which may inadvertently cause damage to the appliance and its electronic componentry.
-
Cleaning and user maintenance shall not be made by children without supervision.
SPECIFIC INSTRUCTIONS FOR WATER FILTER
- Filter cartridge should be kept out of reach of children.
- Store any unused filter cartridges in a dry place sealed in the original packaging.
- Protect filter cartridges from heat and direct sunlight. Only remove from packaging before using.
- Do not use a filter cartridge that is damaged.
- Do not open filter cartridge housing to access the material inside.
- If you are absent for a prolonged period of time, empty and clean the water tank and replace the filter cartridge before next use.
- Refer to the filter installation instructions found in the ‘Assembly’ section of these instructions.
BREVILLE ASSIST™ PLUG
- Your Breville appliance comes with a unique Assist™ Plug, conveniently designed with a finger hole in the power plug for easy and safe removal from the power outlet. For safety reasons, it is recommended you plug your Breville appliance directly into its own electrical outlet on a dedicated circuit separate from other
appliances. If the electric circuit is overloaded with other appliances, your appliance may not function properly. Use in conjunction with a power strip or extension cord is not recommended.
FOR HOUSEHOLD USE ONLY SAVE THESE INSTRUCTIONS
Components
Features
CONTROL PANEL
WHAT IS THE AQUASTATION™ WATER PURIFIER?
The Breville AquaStation™ water purifier when used with the Active360™ 4-stage fast flow water filtration system, provides cleaner, great tasting ambient filtered water. 4 distinct levels of filtration removes contaminants from water that can cause bad taste and odour, which may potentially be harmful to your health.
-
Stage 1- Pre-Sediment Mesh Filter
Filters microplastics and floating particles -
Stage 2- Ion-Exchange Resin Filter
Filters limescale and metals -
Stage 3- Activated Carbon Filter
Filters Pesticides and Chlorine -
Stage 4- Post Filter
Filters fine particles
*4-stage fast flow filtration tested and/or certified to remove/reduce microplastics, floating particles/sediment, pesticides, chlorine, limescale & heavy metals. For more information, visit Breville.com
No Plumber Required
The water purifier will start to work as soon as assembled, water is added and
connected to a power source; then simply press to dispense filtered water. No
need to plumb into mains water.
Filter Life Counter
The AquaStation™ water purifier reminds you to replace the filter every 90
days or approximately 200L of water*, whichever comes first, to ensure the
best filtration performance.
You may choose to change your filter more frequently in areas with poor water
quality.
Filter Replacement Alert
The filter replacement alert will indicate when it is time to change the
filter. Once the filter is replaced, reset the filter time to start the filter
life countdown.
*The filter replacement alert is set at 90 days or approximately 200L of water, whichever comes first, with performance based on typical municipal drinking water quality, however, water quality may vary considerably from one area to the next which may affect the life of the water filter and more frequent replacement may be required.
Water Level Sensor
The water tank is equipped with a floating sensor which will automatically
stop dispensing when the water level becomes too low and the Fill Tank
indicator will illuminate.
NOTE
Take care when removing the water tank from the base after use as residual
water may drip.
One-way Water Tank Valve
The water tank has been designed with a one-way valve so that it can be
removed from the purifier even if water is still in the tank.
Be mindful however that there may be some residual water droplets when removed
from the base of the purifier.
Removable & Magnetic Drip Tray
The drip tray can easily be removed to accommodate different sizes of cups and
bottles. The magnetic edge helps to keep the tray in place.
*BPA Free Materials*
All parts that come into direct contact with water are made of BPA Free
materials
- Breville makes its BPA Free claim for this product based on independent laboratory testing performed for all the food contact plastic materials of the product per EU Commission regulation No 10/2011. BPA Free Material is used in all parts that come into contact with food.
WATER QUALITY
As far as contained in tap water, the contaminants or other substances reduced
by the Activ360 water filter are not necessarily in all users’ water. Tap
water may contain impurities and heavy metals such as lead, copper, chlorine,
limescale, pesticides and other contaminants like microplastics which all lead
to impaired taste.
⚠ CAUTION
Do not use with water that is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system. This
product should only be used with water that has been adequately chlorinated or
disinfected. For use with municipal cold water only.
Assembly
BEFORE FIRST USE
- Remove and safely discard any packaging material or promotional labels attached to your water purifier and filter. Check for any missing or damaged parts as per the components list.
NOTE
As an important part of our quality control process, your water purifier has
been individually tested. As a result, you may notice a small amount of
condensation or water droplets on the inside of the water tank. There is no
need for concern. Please remove and discard the red silicone rubber cap off
the spout before use.
- Remove the Actve360™ 4-Stage filter from the water tank and set aside.
- Do not wash the filter or insert into the upper water tank until ‘Flushing the Breville AquaStation’ and ‘Preparing the 4-Stage Filter’ instructions are completed as found in this book.
- Place the water purifier on a dry, flat level surface.
- Wash the water tank lid, upper (pre-filtered) water tank, lower (filtered) water tank in warm soapy water with a soft, non-abrasive cloth. Rinse and dry thoroughly with a clean, soft, lint-free cloth and return to the purifier.
- Assemble the water tank back on to the power base.
- Plug the power plug into a 230/240V power outlet and turn on the power outlet.
⚠ IMPORTANT
When moving the water purifier, always lift from the base using two hands and
set down gently on a flat and level surface.
FLUSHING THE BREVILLE AQUASTATION
It is important to flush and rinse the dispensing system before using the water purifier for the first time. Before first use, it is recommended to carry out the below steps without the Activ360™ Water Filter in place.
- Fit only the larger lower (filtered) water tank into place on the base of the purifier with the lid removed.
- Fill the lower tank with cold tap water to the MAX level. Never fill past the MAX level.
- Place a 1L container under the dispensing spout.
- Press the START/STOP button once to start dispensing water until the container is full, then press the START/STOP button again to stop dispensing. Discard the collected water.
- Repeat steps 3-5 until all the water in the lower tank has been dispensed. The water purifier will stop dispensing automatically when the water level is too low or automatically after 60 seconds.
- Proceed to the next step, ‘Preparing the Activ360™ Filter’.
PREPARING THE ACTIV360™ FILTER
Flushing the filter is required every time you insert a new filter cartridge.
The filter replacement alert will notify after 90 days or 200L of water filtered that it is time to replace the filter cartridge.
![Breville LWA100 the AquaStation Purifier User Manual
- PREPARING THE ACTIV360™ FILTER](https://manuals.plus/wp- content/uploads/2022/08/Breville-LWA100-the-AquaStation-Purifier-User-Manual- PREPARING-THE-ACTIV360™-FILTER-4.jpg)
NOTE
When preparing the Activ360™ filter for the first time use of your
AquaStation™, there is no need to action step 8 for filter reset; once the
filter is installed, the purifier will automatically begin the filter life
counter.
- A dirty filter may reduce the performance of the water purifier.
- The filter is not washable.
- Use only the original Breville filter specifically intended for use with the AquaStation water purifiers.
- Filter replacement alert is set to 90 days or approximately 200L of water, whichever comes first, however, for higher-than-normal consumption or poor water quality, more frequent changing may be required. If you need to change your filter before the filter replacement alert activates at 90 days or approximately 200L, press and hold the START/STOP button for 3 seconds to enter filter reset mode, water droplet light will flash in RED, then press the START/STOP button once to reset the filter once you have changed the filter cartridge.
NOTE
To exit filter reset mode without resetting the filter, press and hold the
START/STOP button once again for 3 seconds.
- The purifier will beep once and the water droplet LED light will stop flashing. The filter reset has now been completed.
- Water quality varies considerably from one area to the next and has an effect on the life of the water filter cartridge. For optimum performance, the filter change alert will activate after 90 days.
NOTE
- No filter or an incorrectly fitted filter may cause the water purifier to operate less effectively and/or may cause damage to the water purifier.
- The filter must be fitted in the filter holder with the pull ring facing upwards.
- From time to time, small floating black particles may escape from the filter into the water. This is a natural carbon fibre which is food grade safe and not harmful to health.
NOTE
For replacement water filters, visit Breville.com or contact Breville Customer Service.
Operation
OPERATING YOUR AQUASTATION PURIFIER
- Ensure the upper pre-filtered water tank is assembled inside the lower filtered water tank, and that the water filter cartridge is correctly fitted into position.
- Plug into a 230/240V power outlet.
- Remove the water tanks from the purifier and fill the pre-filtered water tank with cold tap water to the MAX level. Alternatively, pour water into the tanks using a water jug. Never fill past the MAX level.
- Once water has filtered into the filtered water tank, the pre-filtered water tank can be topped up until both water tanks are filled to the MAX level.
- With the now filled water tanks assembled to the purifier base, place a cup of choice onto the drip tray, or alternatively, remove the drip tray to accommodate large glasses.
- Press the START/STOP button once to dispense water. Press START/STOP again to stop water dispensing.
NOTE
If the START/STOP button is not pressed a second time to stop dispensing
water, the unit will automatically stop dispensing water after 60 seconds.
NOTE
Always ensure the water tanks are filled to the MAX level for optimum flow of
water from the spout. Never allow the water tanks to fall below the MIN level.
The water sensor will automatically stop dispensing and the Fill Tank
indicator will illuminate when the water level becomes too low. Regularly
check and discard any water that might accumulate in the drip tray.
TURNING OFF THE MACHINE
Turn off at the power outlet.
NOTE
Discard any filtered water that has been left sitting for several days or
more. This will ensure you have cleaner, great-tasting water.
If your filter has been unused for a long period of time, it is recommended to recook the filter for 10 minutes before use and clean the water tanks as per the cleaning instructions found in this book.
Ambient water temperature will vary. The temperature dispensed will be influenced by the external factors surrounding the purifier itself. An increase in the air temperature will cause water tank temperature to increase as well.
If the water temperature in the tank becomes too warm, discard and replace with cold tap water. Water temperature in the tank should not be dispensed if above 40°C.
Care, Cleaning & Storage
⚠ CAUTION
To prevent damage to the appliance, do not use alkaline or abrasive cleaning
agents, steel wool or scouring pads as these can damage the surface of the
appliance. Do not place any part of this appliance in the dishwasher.
CLEANING THE AQUASTATION
- Remove the plug from the power outlet before cleaning.
- Discard any water in the water tanks, then separate the pre-filtered water tank from the filtered water tank. Remove the filter cartridge from the filter holder.
- Wipe the water tanks with a clean, damp, lint-free cloth. The filter is not washable.
CLEANING THE OUTER HOUSING
- Wipe with a soft, damp cloth followed by a soft, dry cloth to polish.
- Alternatively, purchase a stainless steel cleaner such as Breville’s Stainless Steel Cleaner & Polish and follow directions.
- Do not use abrasive cleansers, pads or cloths which can scratch the surface.
CLEANING THE WATER SPOUT
Residue build-up or foreign substances, such as dust or lint, may accumulate
in the water outlet. Clean the spout periodically using a soft brush (not
included).
NOTE
For Breville’s Stainless Steel Cleaner & Polish, visit Breville.com or contact
Breville Customer Service.
CLEANING THE DRIP TRAY
The drip tray should be removed, emptied and cleaned after each use. Empty the
tray before removing the top grill and cleaning.
Remove the drip tray from the purifier and discard any water.
- Separate the top grill from the drip tray.
- Wash the drip tray and grill in warm soapy water and dry thoroughly.
- Place the grill back onto the drip tray then push the assembled drip tray back into position in front of the purifier using the magnetic connection.
⚠ WARNING
To protect against electric shock, do not immerse cord, plug or appliance in
water or any other liquid or allow moisture to come into contact with these
parts.
STORAGE
Remove the plug from the power outlet. Follow the ‘Care & Cleaning’
instructions, ensuring the appliance is completely empty, clean and dry before
storing. Stand the appliance upright. Do not store anything on top. If stored
for a long period, we recommend following the ‘Flushing the AquaStation™’ and
‘Preparing the Activ369 Filter’ instructions
found in this book before using the appliance again.
NOTE
For Breville’s Stainless Steel Cleaner & Polish, visit Breville.com or contact
Breville Customer Service.
Troubleshooting
If you cannot remedy problems by using the troubleshooting chart above, contact Breville Customer Service.
Breville Customer Service Centre
Australian Customers
Phone: 1300 139 798
Web: www.breville.com
New Zealand Customers
Phone: 0800 273 845
Web: www.breville.com
Breville, the Breville logo, AquaStation and Activ360 are trademarks of
Breville Pty Ltd. All other brands may be trademarks of their
respective owners. Breville’s products are distributed in New Zealand under
licence A.B.N. 98 000 092 928.
Approved by the appropriate electrical supply authorities.
Made in China to our specifications.
Due to continued product improvement, the product illustrated on this carton may vary slightly from the actual product.
LWA100 E22
Documents / Resources
|
Breville LWA100 the AquaStation
Purifier
[pdf] User Manual
LWA100, the AquaStation Purifier, LWA100 the AquaStation Purifier, AquaStation
Purifier, Purifier
---|---
Read User Manual Online (PDF format)