ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual

June 9, 2024
ENCELIUM

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction
Manual

The VISION Sensor is a motion sensor ideal for large areas such as open-plan offices, corridors and storage rooms. The VISION Sensor can be used as a standalone solution or as part of the Encelium X Lighting Control System with the addition of a DALI High-Bay Adapter. For more information on product specifications and design tools visit encelium.com.

PRODUCT SAFETY

READ THESE INSTRUCTIONS BEFORE USING THE

When using electrical equipment, basic safety precautions should always be followed, including the following:
⚠ Do not mount near gas or electric heaters or let power supply cords touch hot surfaces.
⚠ Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
⚠ The use of accessory equipment is not recommended by Encelium as it may cause an unsafe condition.
⚠ All DALI channels are internally connected together to the control unit. Make sure to consider this when installing.
⚠ Do not use this equipment for other than the intended use.

SAVE THESE INSTRUCTIONS.

WIRED SYSTEM OVERVIEW

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
WIRED SYSTEM OVERVIEW

Encelium X enables you to control DALI devices. With any Encelium wired design, you get a reliable, lighting control system that can be installed quickly and easily.

STEP 1
Remove the VISION Sensor cover by turning it counterclokwise. Place cover aside.
Proceed to Step 2 if you are installing the VISION Sensor into the DALI High- Bay Adapter.

STEP 2

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
Remove the DALI High-Bay Adapter cover Remove the DALI High-Bay Adapter cover by turning it counterclokwise and lifting up.

STEP 3

CEILING INTEGRATION WITH DALI HIGH-BAY ADAPTER

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
Ceiling Opening

Cut a Ø 22 mm (0.87 inch) hole in the ceiling. Line up the DALI High-Bay Adapter holes to the ceiling hole and screw into the ceiling. Connect the Mains and DALI wires into the DALI High-Bay Adapter connector block. Connect the VISION Sensor wires into the DALI High-Bay Adapter connector block. Place the VISION Sensor into the DALI High-Bay Adapter and push until it clicks into place. Then install the VISION Sensor Cover by turning clockwise until it is secure.

DALI HIGH-BAY ADAPTER FEATURES

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
DALI HIGH-BAY ADAPTER FEATURES

The DALI High-Bay Adapter features a SELECT Button, Sensitivity Adjustment, Light Sensor, and LED Indicator. To confirm wiring connections quickly press the SELECT Button. If DALI voltage is present the LED Indicator will turn on. Another quick press to the SELECT Button will turn off the LED Indicator, otherwise it will switch off after 30 seconds. The Sensitivity Adjustment allows the lights to be set from bright to dark. The Light Sensor can be adjusted in its sensitivity by a potentiometer for optimize measurement window usage (see the Light Sensitivity Range details below).

Light Sensitivity Range

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
Light Sensitivity Range

VISION SENSOR FEATURES

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
VISION SENSOR FEATURES

The VISION Sensor features an LED Indicator, Motion Sensor, and Delay Button. The Delay Button is used to set the delay between 10 seconds and 20 minutes (see the Delay Button Settings details below).

Delay Button Settings

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
Delay Button Settings

FACTORY DEFAULT SETTINGS

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
FACTORY DEFAULT SETTINGS

To reset the DALI High-Bay Adapter to factory default settings , press and hold the SELECT button for approximately 10 seconds. The LED Indicator will blink for 4 seconds.
Note: This does not reset the VISION Sensor to factory default settings.

SENSOR DETECTION RANGE

The detection range of the High-Bay Sensor must be set before it can detect motion. Place objects that radiate heat outside the detection area and avoid drafts.

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
Coverage Area

Sensor Detection Range

ENCELIUM WCMS Wireless Ceiling Mount Passive Infrared Instruction Manual -
Sensor Detection Range

VISIT OUR HELP CENTER

https://help.encelium.com/category/zo5v0jr3ss-installation-and-site- readiness

For instructions to install, configure, test, or use Encelium products or systems, or to contact an Encelium Technical Support Specialist, please scan the QR code or visit help.encelium.com.

THIS PAGE IS INTENTIONALLY LEFT BLANK

encelium.com
Copyright © 2022 Digital Lumens, Incorporated. All rights reserved. Digital Lumens, the Digital Lumens logo, We Generate Facility Wellness, SiteWorx, Light Rules, Light elegance, Encelium, the Encelium logo, Polaris, Green Bus and any other trademark, service mark, or tradename (collectively “the Marks”) are either trademarks or registered trademarks of Digital Lumens, Inc. in the United States and/or other countries, or remain the property of their respective owners that have granted Digital Lumens, Inc. the right and license to use such Marks and/or are used herein as nominative fair use. Due to continuous improvements and innovations, specifications may change without notice. DOC-000464-00 Rev A 11-22

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals