ENCELIUM High Bay Sensor Instruction Manual

June 9, 2024
ENCELIUM

ENCELIUM-logo

ENCELIUM High Bay Sensor

GETTING STARTED

OVERVIEW
The High-Bay Sensor is a motion sensor ideal for industrial lighting applications, such as production halls. The High-Bay Sensor can be used as a standalone solution or as part of the Encelium X Lighting Control System with the addition of a DALI High-Bay Adapter. For more information on product specifications and design tools visit encelium.com.

PRODUCT SAFETY

READ THESE INSTRUCTIONS BEFORE USING THE PRODUCT
When using electrical equipment, basic safety precautions should always be followed, including the following:

  • Do not mount near gas or electric heaters or let power supply cords touch hot surfaces.
  • Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
  • The use of accessory equipment is not recommended by Encelium as it may cause an unsafe condition.
  • All DALI channels are internally connected together to the control unit. Make sure to consider this when installing.
  • Do not use this equipment for other than the intended use.
    SAVE THESE INSTRUCTIONS

WIRED SYSTEM OVERVIEW

Encelium X enables you to control DALI devices. With any Encelium wired design, you get a reliable, lighting control system that can be installed quickly and easily.

ENCELIUM-High-Bay-Sensor-FIG-2

INSTALLATION INSTRUCTION

  • STEP 1
    Remove the High-Bay Sensor cover by turning it counterclockwise. Place cover aside.

Proceed to Step 2 if you are installing the High-Bay Sensor into the DALI High-Bay Adapter.

  • STEP 2
    Remove the cover plate by turning counterclockwise and lifting up. The included cover plate is not needed when the High-Bay Sensor is mounted into the DALI High-Bay Adapter.

ENCELIUM-High-Bay-Sensor-FIG-4

  • STEP 3: CEILING INTEGRATION WITH DALI HIGH-BAY ADAPTER
    Cut a Ø 22 mm (0.87 inch) hole in the ceiling. Line up the DALI High-Bay Adapter holes to the ceiling hole and screw into the ceiling. Connect the Mains and DALI wires into the DALI High-Bay Adapter connector block. Connect the High-Bay Sensor wires into the DALI High-Bay Adapter connector block. Place the High-Bay Sensor into the DALI High-Bay Adapter and push until it clicks into place. Then install the High-Bay Sensor Cover by turning clockwise until it is secure.

ENCELIUM-High-Bay-Sensor-FIG-5

DALI HIGH-BAY ADAPTER FEATURES

The DALI High-Bay Adapter features a SELECT Button, Sensitivity Adjustment, Light Sensor, and LED Indicator. To confirm wiring connections quickly press the SELECT Button. If DALI voltage is present the LED Indicator will turn on. Another quick press to the SELECT Button will turn off the LED Indicator, otherwise it will switch off after 30 seconds. The Sensitivity Adjustment allows the lights to be set from bright to dark. The Light Sensor can be adjusted in its sensitivity by a potentiometer for optimize measurement window usage (see the Light Sensitivity Range details below).

ENCELIUM-High-Bay-Sensor-FIG-6

Light Sensitivity Range

Mounting Height Montagehöhe Hauteur de Montage Altura de Montaje| Bright Hell Brillant Brillante| Gray Grau Gris Gris| Black Schwarz Noir Negro
---|---|---|---
5 to 8 m (16.4 to 26.5 ft)| 1|  |
7 to 10 m (23 to 33 ft)|  | 3|
10 to 13 m (33 to 42.6 ft)|  |  | 5

HIGH-BAY SENSOR FEATURES

The High-Bay Sensor features an LED Indicator, Motion Sensor, and Delay Button. The Delay Button is used to set the delay between 10 seconds and 20 minutes (see the Delay Button Settings details below).

ENCELIUM-High-Bay-Sensor-FIG-13

Delay Button Settings

ENCELIUM-High-Bay-Sensor-FIG-7

FACTORY DEFAULT SETTINGS

To reset the DALI High-Bay Adapter to factory default settings, press and hold the SELECT button for approximately 10 seconds. The LED Indicator will blink for 4 seconds.
Note: Resetting to factory default settings will delete the DALI short address and require the device to be re-commissioned. This does not reset the High-Bay Sensor to factory default settings.

ENCELIUM-High-Bay-Sensor-FIG-8

SENSOR DETECTION RANGE

The detection range of the High-Bay Sensor must be set before it can detect motion. Place objects that radiate heat outside the detection area and avoid drafts.

ENCELIUM-High-Bay-Sensor-FIG-9

Sensor Detection Range

ENCELIUM-High-Bay-Sensor-FIG-10

SENSOR LENSES

To install one of the supplied sensor lens stickers (middle or end), peel off the adhesive backing and push the adhesive side down onto the lens.

ENCELIUM-High-Bay-Sensor-FIG-11

VISIT OUR HELP CENTER

For instructions to install, configure, test, or use Encelium products or systems, or to contact an Encelium Technical Support Specialist, please scan the QR code or visit help.encelium.com.

ENCELIUM-High-Bay-Sensor-FIG-12

Copyright © 2022 Digital Lumens, Incorporated. All rights reserved. Digital Lumens, the Digital Lumens logo, We Generate Facility Wellness, SiteWorx, LightRules, Lightelligence, Encelium, the Encelium logo, Polaris, GreenBus and any other trademark, service mark, or tradename (collectively “the Marks”) are either trademarks or registered trademarks of Digital Lumens, Inc. in the United States and/or other countries, or remain the property of their respective owners that have granted Digital Lumens, Inc. the right and license to use such Marks and/or are used herein as nominative fair use. Due to continuous improvements and innovations, specifications may change without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals