MODEL
LG ESS Home 10 (D010KE1N211)
LG ESS Home 8 (D008KE1N211)

Safety Information

IMPORTANT : THIS PRODUCT SHOULD NOT BE USED FOR ANY PURPOSE OTHER THAN THE PURPOSE DESCRIBED IN THIS INSTALLATION MANUAL.

WARNING Indicates a potentially dangerous situation. death or serious injury may result if appropriate precautions are not taken.

  • There is high possibility of electric shock or serious burns due to the high voltages in power conditioning circuits.

  • High voltages on AC and DC cables. Risk of death or serious injury due to electric shock.

  • A potentially hazardous circumstance such as excessive heat or electrolyte mist may occur due to improper operating conditions, damage, misuse and/or abuse.

  • This product have potential danger such as death or serious injury by fire, high voltages or explosion if appropriate precautions are not read or fully understood.

  • Do not place flammable or potentially explosive objects near the product.

  • Do not place any kind of objects on top of the product during operation.

  • All works on the PV modules, power conditioning system, and battery system must be carried out by qualified personnel only.

  • Electrical installations must be done in accordance with the local and national electrical safety standards.

  • Wear rubber gloves and protective clothing (protective glasses and boots) when working on high voltage/high current systems such as PCS and battery systems.

  • There is a risk of electric shock. Do not remove cover. There is no user serviceable parts inside.
    Refer servicing to qualified and accredited service technician.

  • Electrical shock hazard. Do not touch uninsulated wires when the product cover is removed.

  • In the event of fault, the system must not be restarted. Product maintenance of repairs must be performed by qualified personnel, or personnel from an authorized support center.

  • If non LG Electronics batteries are connected to LG PCS, it will void warranty of the PCS and battery.

CAUTION Indicates a situation where damage or injury could occur. If it is not avoided, minor injury and/or damage to property may result.

  • This product is intended for residential use only and should not be used for commercial or industrial.

  • Before testing electrical parts inside the system, it takes at least 10-minute standby period of time to complete discharging the system.

  • This inverter includes an integrated residual current device (RCD). If an external residual current device (RCD) is used, a device of type A or B should be used, with a tripping current of 30 mA or higher.

  • The contents included in this box are power conditioning system and its accessories, and the entire weight is very heavy. Serious injury may occur due to the heavy weight of the package with PCS and accessories. Therefore, special care must be taken in handling. Make sure to have at least two persons deliver and remove the package.

  • Do not use the damaged, cracked or frayed electrical cables and connectors. Protect the electrical cables from physical or mechanical abuse, such as being twisted, kinked, pinched, closed in a door or walked upon. Periodically examine the electrical cables of your product, and if its appearance indicates damage or deterioration, discontinue use of this product, and have the cables replaced with an exact replacement part by a qualified personnel.

  • Ensure that you connect the earth ground wire to prevent possible electric shock. Do not try to ground the product by connecting it to telephone wires, lightning rods or gas pipes.

  • The product should not be exposed to water (dripping or splashing) and no objects filled with liquids, such as vases, should be placed on the product.

  • To prevent fire or electric shock hazard, do not expose this production to rain or moisture.

  • Do not block any ventilation openings. Ensure reliable operation of the product and protect it from over heating. The openings shall never be blocked by placing any object on this product.

  • The temperature of metal enclosure may be high during operation.

  • In order to avoid radio-interference, all accessories (like a energy meter) intended for connection to the product shall be suitable for use in residential, commercial and light-industry areas. Usually this requirement is fulfilled if the equipment complies with the class B limits of EN55022.

  • The product must be disposed of according to local regulations.

  • The electrical installation of this unit must only be performed by LGE service person or trained installer, qualified to install PCS.

  • If the AC circuit breaker is turned off and the PCS is not operated for a long time, the battery may be overdischarged.

  • Connect the DC+ and DC- cables to the correct DC+ and DC- terminals on the product.

  • Danger of damaging the PCS by overload. Only connect the proper wire to DC terminal block.
    Refer to the installation wiring diagram for details.

  • Do not step on the product or the product package. The product may be damaged.

  • Do not leave the ESS in the Fault standby state for a long time because of the battery discharge may occur during the long standby state.

  • If the battery fault occurs immediately after starting PCS it means Battery failure. Check the battery SOC also voltage and fault information, and turn off the power of the ESS until service action is taken.

  • If the battery SOC is low, the battery may charge from the grid for self-protection. (Emergency Charging) This function is to prevent shutdown of the ESS, deep discharge and failure of the battery. An Emergency Charge is not an ESS fault.

  • If the battery SoC is too low during the backup operation of a power outage, the PCS will only charge the battery from Solar PV. It means no power is supplied to the home load. Emergency Charging(backup) will charge the battery up to the backup SoC level that you set (30% by default). Emergency Charging(backup) is not an ESS fault.

  • Install the PCS where the noise from the PCS will not inconvenience the neighbors. Failure to do so may result in conflict between neighbors.
    NOTE Indicates a risk of possible damage to the product.

  • Before making connections, please make sure the PV array open circuit voltage is within 1000 V. Otherwise the product could be damaged.

  • Never use any solvents, abrasives or corrosive materials to clean this product.

  • Do not store on or place against any objects to the product. It may cause serious defects or malfunction.

  • Before making a connection, make sure the PV switch on this product is switched off.

  • This unit is designed to feed power to the public grid only. Do not connect this unit to an AC source or generator. Connecting the product to external devices could result in serious damage to your equipment.

  • Serving of batteries should be performed or supervised by LG service person or trained installer.

  • The battery does not discharged when the load is under the certain level.

  • This product can cause current with a DC component. Where a Residual Current-operated protective (RCD) or monitoring (RCM) device is used for protection in case of direct or indirect contact, only an RCD or RCM of Type A (or type B) is allowed on the supply side of this product.

  • This product is designed to be installed indoor use only. Do not install this product outdoor.

  • This document is for your reference only. Read the installation manual on the website below.

  • Please check the following website for warranty policy.
    https://www.lg.com/global/business/ess/business-resources/download

LED Indications

LED Color Description
Power Off Grid is not connected.
White Grid is connected.
White (blink) PCS Fault
Solar Off Energy is not being generated.
Green Energy is being generated.
White (blink) PCS Fault
Battery Off Stand by
Green Battery is in charging
blue Battery is in discharging
Red (blink) Battery error
White (blink) PCS Fault
WLAN Off Not connected
Green Network connected
blue WLAN network connected
Red (blink) Network disconnected

Symbol used on the Label

Symbol Description Symbol Description

DC INPUT


(OVC||)| Direct current input| AC OUTPUT (3/N/PE-) ∼ 3N( OVC||)| Three phase four wire alternating current conductor
IP21| This product is protected against insertion of fingers and will not damaged during a specified test in which it is exposed to
vertically dripping water.| | This product should not be disposed of with other household waste. Disposal regulations should be observed in this country.
| Caution, risk of danger| | Refer to the installation manual or operating manual.
| Caution, hot surface| | Caution, risk of electric shock, energy storage timed discharge
****| The relevant equipment complies with the requirements in the EU guidelines.

Choice of Location

LG D010KE1N211 D008KE1N211 Energy Storage System-

Connection Overview

LG D010KE1N211 D008KE1N211 Energy Storage System-fig1

WARNING

  • Electrical shock hazard. Do not touch uninsulated wires when the PCS cover is removed.
  • Before starting electrical cable connections or removing the cover, turn off the AC circuit breaker, PV switch and DC circuit breaker of the battery. (In case of re-installation, turn them off and wait at least 10-minute standby period of time for complete discharge within this product.)
  • When the photovoltaic array is exposed to light, it supplies a DC voltage to the PCS.

Connecting to a Mobile Device
To connect the system to a mobile device, the LG EnerVu Plus mobile application must be installed on your mobile device. Search and download ‘LG EnerVu Plus’ application from Apple App store or Google Play store.
To connect to the system directly, the WLAN dongle must be connected to the system. Make sure that the supplied WLAN dongle is connected to the system.

LG D010KE1N211 D008KE1N211 Energy Storage System-fig2

Installing ‘LG EnerVu Plus’ App
Download ‘LG EnerVu Plus’ on the Apple App Store or Google Play Store.

OR

|
---|---
https://play.google.com/store/apps/details?id=com.lge.ess| https://itunes.apple.com/us/app/lg-enervu- plus/id1333407626?l=ko&ls=1&mt=8

NOTE

  • Depending on the device, ‘LG EnerVu Plus’ app may not work.
  • LG EnerVu Plus app will be available in version of the software as follow;
    – Android O/S : Lollipop (5.0) or later
    – iOS O/S : iPhone 6 (9.0) or later

Connect via Home WLAN
Preparation
• To connect the mobile device with the system via home network, the system must be connected to your home network. Check the [Network] setting menu on the system.
• Note the SSID of your home network.

  1. Run ‘LG EnerVu Plus’ app on your mobile device.
    LG D010KE1N211 D008KE1N211 Energy Storage System-fig4

  2. Tap [Connect via Home WLAN] in the connection method selection screen.
    LG D010KE1N211 D008KE1N211 Energy Storage System-fig5

  3. The connection will automatically be proceeded and main screen appears when the connection is successful.

  4. If the connection fails, a pop-up message appears on the screen.
    Tap [OK] to move to the WLAN selection menu of the mobile device.
    Select the SSID of your home network.
    LG D010KE1N211 D008KE1N211 Energy Storage System-fig7

Connect directly to ESS

  1. Run ‘LG EnerVu Plus’ app on your mobile device.
    If it is the first time to connect to the system, connection method selection screen appears.
    Tap [Connect directly to ESS] option.
    LG D010KE1N211 D008KE1N211 Energy Storage System-fig8

  2. Press and hold the wireless connection button on the system until [WLAN] LED is lights in blue. On your mobile device, tap [OK] to go to the next step.
    NOTE
    If the connection has not been made for 5 minutes, the [WLAN] LED lights green and the WLAN signal is disabled.
    LG D010KE1N211 D008KE1N211 Energy Storage System-fig9

  3. Read the guidance and tap [OK] to display WLAN selection screen.
    Select the SSID which starts with ‘LGE_ESS’.
    The password input screen appears.
    NOTE
    The last 2 characters of the SSID are the same as the last 2 characters of the system registration number.
    Example : SSID (LGE_ESS-5e)
    Registration No. (LGE-ESS-DE1710BKRH00685e)

  4. Input WLAN password in the password field to connect to the system.
    The WLAN password is 8 digit numbers. Find the ‘WLAN password’ printed in the label outside of the PCS.
    NOTE
    If the connection failed, try after turning off the mobile data option on your mobile device.
    Android : If the connection is successful, main screen appears as shown in the figure.
    iOs : If the connection is successful, run [LG EnerVu Plus] app to display the main screen as shown in the figure.

ESS Status Menu
The main screen displays and indicates current ESS status briefly. When you select an area indicated above, it displays detailed information.

LG D010KE1N211 D008KE1N211 Energy Storage System-fig12

NOTE

  • The displayed values are not exact values. The values may differ from actual values.
  • Please turn on the AP again, if there is a problem at connection with AP.

Displays a notice list of system status.
When there is an error occurred, error code, time and date are displayed on the list.
Refer to installation manual for more information of messages.

LG D010KE1N211 D008KE1N211 Energy Storage System-fig14

Displays the [Energy Overview] information on the screen.
Today’s self-consumption rate : Displays rate of the consumed energy amount from ESS today.
This month’s cO2 reduction : Displays monthly amonut of CO2 reduction.
Generation: Displays generated energy information. feed-in : Displays consumed energy information.
Pcs : Displays PCS information.

Displays generating status of the connected PV briefly.
The status values are the sum of PV1, PV2 and PV3.
Brand : PV Manufacturer (Default : LGE) system capacity : PV capacity
DC Voltage : Current PV voltage
DC Power : Current PV power
DC current : Current PV electric current
Today’s generation: Generated PV energy today.

LG D010KE1N211 D008KE1N211 Energy Storage System-fig16

Displays detailed status of energy consumed in household.
Load Power : Current power consumed in household Today
Total consumption : Amount of consumed energy today
From PV : Amount of energy from PV to household today
From battery : Amount of energy from the battery to household today
From Grid : Amount of energy from the power grid to household today
This month
Total consumption : Amount of consumed energy this month
From PV : Amount of energy from PV to household this month
From battery : Amount of energy from the battery to household this month
From Grid : Amount of energy from the power grid to household this month

LG D010KE1N211 D008KE1N211 Energy Storage System-fig17

Displays charging and discharging status of the battery briefly.
battery status : Charging/Discharging/
Standby battery sOc: Current SOC (state of charge) level 2
Operating
Winter Mode : Shows winter mode status.
Dc Power : Current output power from battery
Today
Charging : Amount of charged energy to the battery today.
Discharging : Amount of discharged energy from the battery today
This month
charging : Amount of charged energy to the battery in this month
discharging : Amount of discharged energy from the battery in this month Displays current status of power grid.
Power: Current grid power
Voltage: Current grid voltage
frequency : Current grid frequency
Today
Into Grid : Amount of sold energy today
From Grid : Amount of purchased energy today
This month
Into Grid : Amount of sold energy today and this month
From Grid : Amount of purchased energy this month
[System Operating]
Tap switch to start or stop system operation.

ESS Setting Menu
You can adjust general settings of the system. Select [main screen] > [ ] to display the [Setting] screen.
Language
Select [ ] > [Language] to display the language selection screen. Select the desired language.

Battery

Select [ ] > [Battery] to display the battery setting screen.

[Winter mode]
Tap this switch to select [Enable] or [Disable].
The minimum SOC level of winter mode can be changed by the installer only.
[Backup mode]
Tap this switch to select [Enable] or [Disable].
The minimum SOC level of Backup mode can be changed by the installer only.
[Operation Mode]
Tap this switch to select [Economic Mode] or
[Fast Charge Mode]. You can change mode on your own.
Economic Mode : Make Feed- in more and make more efficiency to System.
Fast charge Mode : Make fast charge to battery first.
[Winter Mode Period]
Tap current value to display the setting menu. You can change the period

  1. Select the currently selected value. Period setting menu is displayed.
  2. Adjust [Month] and [Day] using S or W.
  3. Select [APPLY] to complete the setting.

Quick Install Guide

Select [ ] > [Quick install guide] to display the install guidance screen.
You can check the brief installation instruction on the [Quick install Guide] screen.

Open source

You can check the open source information of the application and the system.
Select [ ] > [Open source] to display the open source notice screen.
To obtain the source code under GPL, LGPL, MPL, and other open source licenses, that is contained in this product, please visit http://opensource.lge.com.
In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are available for download. LG Electronics will also provide open source code to you on CD-ROM for a charge covering the cost of performing such distribution (such as the cost of media, shipping, and handling) upon email request to [email protected]. This offer is valid for three(3) years from the date on which you purchased the product.

Application Information

Select [ ] > [Application information] to display the application information screen.

You can check the information of this application such as application name and application version.
Energy Device
Select [ ] > [Energy Device] to display the Energy Device screen.

[EV]
Tap this switch to select [On] or [Off]. When ‘EV Meter Enable’ not setting, Error Popup occurred.
After setting, EV monitoring can be enable.
[AWHP]
Tap this switch to select [On] or [Off]. When AWHP is not connected, can not be set on and Error Popup occurred.

Installer Settings

The system needs various system settingsby installer when installing. Users are not allowed to enter [Installer Settings] menu. Try not to enter the menu. It may cause serious malfuction on the system, if user changes settings on the[Installer Settings] menu.

ESS Information Menu

Energy Analysis
On [Energy Analysis], you can check the statistical information of this system.
You can review the amount of energy generated, consumed, sold and purchased on this system.
The statistical data of the day, week, month and year are supported.
PV Graph
Analyzes the energy generated and sold from PV within selected period and displays as a graph.

Select [PV Graph] on [Energy Analysis].
Generated energy is marked with green and sold energy is marked with purple on the line graph.
You can change the period by tapping [Day], [Week], [Month] and [Year].
A : Goes to previous [Day], [Week], [Month] or [Year].
D : Goes to next [Day], [Week], [Month] or [Year].
Battery Graph
Analyzes the energy charged and discharged on the battery within selected period and displays as a graph. The usage is the same as the PV graph.
Load Graph
Analyzes the energy consumed and purchased from grid within selected period and displays as a graph. The usage is the same as the PV graph.
System Information

Displays system information of this ESS. You can check information on PCS, battery and network status. Scroll up or down to display next or previous information.

ATS time setting guide

ATS Box – Version 10013677 / 10013678
After 5 seconds of recovering grid power from the outage, the PCS stops the backup mode. At the same time, supplies power to the critical load and the PCS. The PCS will be restarted in normal mode.
Using the EnerVu application, you can set the interval of restarting the system after power recoverFollow the steps as described below.

  1. In the EnerVu application, select [Installer settings] > [PCS] > [Grid] > [Reconn. Condition (Tripping)] > [Observation Time].
  2. Enter an interval value in the [Observation Time] option. The default value is 60 (sec) and the minimum value you can set is 30 (sec).

ATS Box – Version 10013679 (Bender VMD460)
After 5 seconds of recovering grid power from the outage, the PCS stops the backup mode. The power will be supplied to the critical load and the PCS after the time set by the ATS box.
And then, the PCS automatically restarts in normal mode.
Using the EnerVu application, you can set the interval of restarting the system after power recovery.
Follow the steps as described below.

  1. In the EnerVu application, select [Installer settings] > [PCS] > [Grid] > [Reconn. Condition (Tripping)] > [Observation Time].
  2. Enter an interval value in the [Observation Time] option. The default value is 60 (sec) and the minimum value you can set is 30 (sec).
    If the time setting in ATS box is 30 seconds and the PCS settings in [Observation Time] option is 60 seconds, the PCS restarts in 90 seconds after power recovery.

Maintenance

Cleaning the Product
Wipe off the outside of the product with a soft towel with lukewarm water and wipe it with a clean hand towel so that dirt will not occur when using a neutral detergent. When cleaning the outside of the product, do not brush it with a rough brush, toothpaste, or flammable materials. Do not use cleaning agents containing flammable substances.

  • It may cause discoloration of the product or damage to the product.
  • Flammable substances : Alcohol (Ethanol, Methanol, Isopropyl alcohol, Isobutyl alcohol, etc.),
    Thinner, Benzene, Flammable liquid, Abrasive etc.)

Wiping with strong pressure may damage the surface. Do not leave rubber or plastic products in contact with the product for a long period of time.
When cleaning the air duct, shut off all the systems including PCS, PV module, battery, AC circuit breaker. After that, clean the filter with soft brush.
Inspecting Regularly
It is recommended to check the operating status and connection status once a year. It should be done by technician or authorized people. Contact authorized dealer or where you purchased.

Contact

If you have technical problems or questions, contact installation company or LG Electronics.

  1. Installation Company
    Address :
    Tel :

  2. Customer Service
    LG Electronics ESS | Solar Service
    E-Service Haberkorn GmbH Augustenhöhe 7 06493 Harzgerode
    LG Electronics ESS | Solar Service
    E-Service Haberkorn GmbH Augustenhöhe 7 06493 Harzgerode

  3. LG Electronics Contact
    LG Electronics Deutschland GmbH Alfred-Herrhausen-Allee 3-5 65760 Eschborn
    Tel. : + 0049 18 06 807 020
    E-Mail: [email protected]
    LG Electronics Benelux
    Krijgsman 1, 1186 DM, Amstelveen,
    The Netherlands
    Tel: +0031 (0)20 456 3100
    E-Mail: [email protected]

Disposing the Product
When the product reached to the end of its service life or defect beyond repair, dispose the product according to the disposal regulations for electronic waste in your area. Disposing the product must be carried out by qualified personnel only. Contact authorized dealer or where you purchased.

  1. This crossed-out wheeled bin symbol indicates that waste electrical and electronic products (WEEE) should be disposed of separately from the municipal waste stream.
  2. Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health. Your old appliance may contain reusable parts that could be used to repair other products, and other valuable materials that can be recycled to conserve limited resources.
  3. You can take your appliance either to the shop where you purchased the product, or contact your local government waste office for details of your nearest authorised WEEE collection point. For the most up to date information for your country please see www.lg.com/global/recycling

Removal of waste batteries and accumulators
(Product with embedded battery ONly)
In case this product contains a battery incorporated within the product which cannot be readily removed by end-users, LG recommends that only qualified professionals remove the battery, either for replacement or for recycling at the end of this product’s working life. To prevent damage to the product, and for their own safety, users should not attempt to remove the battery and should contact LG Service Helpline, or other independent service providers for advice.
Removal of the battery will involve dismantling of the product case, disconnection of the electrical cables/contacts, and careful extraction of the battery cell using specialized tools. If you need the instructions for qualified professionals on how to remove the battery safely,
please visit http://www.lge.com/global/sustainability/environment/take-back- recycling

Disposal of waste batteries/accumulators

  1. This symbol may be combined with chemical symbols for mercury (Hg), cadmium (Cd) or lead (Pb) if the battery contains more than 0.0005% of mercury, 0.002% of cadmium or 0.004% of lead.
  2. All batteries/accumulators should be disposed separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities.
  3. The correct disposal of your old batteries/accumulators will help to prevent potential negative consequences for the environment, animal and human health.
  4. For more detailed information about disposal of your old batteries/ accumulators, please contact your city office, waste disposal service or the shop where you purchased the product. (http://www.lg.com/global/sustainability/environment/take-back-recycling/global-network-europe)

Specifications

PV Input LG ESS Home 8 LG ESS Home 10
Input Voltage Range 150 – 1 000 V3
Max. DC Power (per channel) 12 kW (6 kW) I 13.5 kW (7.5 kW)
Usable MPP Voltage Range 150 – 800 V
Number of MPPT 3
Number of String per MPPT 1
Max. Input Current per MPPT 13 A
Max. inverter backfeed current to the array 0 A
AC Output LG ESS Home 8 LG ESS Home 10
--- --- ---
Rated Grid Voltage 3-NPE 400 V / 230 V
AC Voltage Range 319-458V/184 – 264.5 V
Frequency(Range) 50Hz (47.5 Hz – 51.5 Hz)
Rated Output Power 8 kVA 10 kVA
Rated Output current 11.5 A 14.4 A
THD / Power Factor < 5 %/± 0.8
Inrush current (peak and duration) 70 Aac / 0.02 ms
Max. output fault current 80 Aac / 20 ms
Max. output overcurrent protection 55.6 Ate,
Backup output LG ESS Home 8 LG ESS Home 10
--- --- ---
Maximum usable home load capacity in backup operation1) Single Battery
LGHB 7H Single Battery

LGHB 10H
LGHBP 10H
LGHBP 16H
LGHBC 11H
LGHBC 15H| Dual Batteries
LGHB 10H+10H
LGHB 10H+7H
LGHB 7H+7H
LGHBP 10H+10H
LGHBP 16H+16H
LGHBC 11H+11H
LGHBC 15H+15H
Total| 3.5 kW| 5 kW| 7 kW
Each phase| 1.2 kW| 1.7 kW| 2.3 kW

  1. The capacity may decrease as the battery ages.

Battery| LGHb /H| WHIT I UH| LGI-1BI-‘ I UH| L(3I-Ib1i I bH
---|---|---|---|---
Battery Type| Lithium Polymer High Voltage
Total Capacity| 7.0 kWh| 9.8 kWh| 9.87 kWh| 16.45 kWh
Usable Capacity| 6.6 kWh “| 9.3 kWh °| 9.6 kWh 2)| 16kWh 2)
Max. Charge/Discharge power (Single/Dual)4)| 3.5 kW / 7kW| S kW / 7 kW
Peak Power (Single/Dual)| 5kW/10 kW for 5 sec.| 7kW/10 kW for 10 sec.
Rated output voltage| 400 V
Communication Interface| RS485
Max. Charge/Discharge Current| 8.5 A@420 V /10 A@350 V| 11.9 A@420 V /14.3 A@350 V
Voltage (nominal or range)| Charge : 400-450 V, / Discharge: 350-430 V„
Battery| LGHBC 11H| LGHBC 1 5H
---|---|---
Battery Type| Lithium ion
Total Capacity| 11.9 kWh| 15.8 kWh
Usable Capacity| 10.7 kWh 3)| 14.3 kWh 3)
Max. Charge/Discharge power (Single/Dual) 4)| Single: 4 kW / 5 kW Dual: 7 kW / 7 kW| 5 kW / 7 kW
Peak Power (Single/Dual)| 7 kW / 10 kW for 10 sec.
Rated output voltage| 305 V| 407 V
Communication Interface| RS485
Max. Charge/Discharge Current| 14A@280V / 17.6A@289V| 13.1A@373V / 14A@385V
Voltage (nominal or range)| Charge : 243-344 Vdc
Discharge : 285-344 Vdc| Charge : 325-458 Vdc
Discharge : 380-458 Vdc

  1. Value for battery cell only (depth of discharge 95 %). Approximately 10 % of the battery usable capacity is used by system for battery protection. The capacity may decrease as the battery ages.
  2. Value for battery cell only (depth of discharge 97.5 %). Approximately 10 % of the battery usable capacity is used by system for battery protection. The capacity may decrease as the battery ages.
  3. Approximately 10 % of the battery usable capacity is used by system for battery protection. The capacity may decrease as the battery ages.
  4. Charging and discharging may take longer depending on ambient temperature and SoC. The specified value relates to the consumption of the entire system. The available capacity to supply the loads depends on the operating behavior of the overall system, the protection against depth charging, the installation location, and the age of the LG ESS battery.

Efficiency (PCS)

Max. Efficiency (PV to Grid) 97.70%

General data
Dimensions (W/H/D, mm)| 450/599/210 (PCS), 746/688/206 (LGHB 7H), 746/903/206 (LGHB
10H), 504/816/295 (LGHBP 10H), 504/1086/295 (LGHBP 16H),
698/1073/205 (LGHBC 11H/15H)
Weight| 34 kg (PCS) / 75 kg (LGHB 10H), 97 kg (LGHB 16H), 112 kg (LGHBP 10H),
160 kg (LGHBP 16H), 117 kg (LGHBC 11H), 142 kg (LGHBC 15H)
Operating temperature| 0 °C to 40 °C (derating at 40-60 °C)
Energy Meter compatibility

ABB| B23 112-100, B23 212-100, B23 312-100
ATs (option)
enwitec| Type 10013677, Type 10013678, Type 10013679

  • An external ATS is required for stand alone mode.
  • For LG Electronics’ ATS Box, you can use enwitec.
  • For installation and connection to the ESS, refer to the ATS Box manual.

Feature & function

Noise emission (Typical) < 40 dB
Cooling Forced convection
Topology Transformerless
Degree of protection IP21
Max. permissible value of relative humidity (non-condensing) 85 % (Climate

class 3K5)
Warranty (PCS)| 10 years
Warranty (Battery)¹| 10 years
Certification (PCS)| 2014/53/EURED, IEC/EN62109-1/-2, EN61000 Series,
EN55011, EN301, EN50549-1:2019, VDE-AR-N 4105,
DIN VDE V 0124-100, TOR, C10/11, OVE-R25, RD1699,
NTS2.0, UNE206007-1, UNE217001/2, TF3.3.1,
AS4777.2
Class B Group 1 Product| Protection Class(Class I)
Pollution degree| 2

  1. Germany (DACH) : SOH 80%, other countries : SOH 60%
  • The noise emission value is measured in a soundproof room and can vary depending on the environment.
  • If you are installing in a place sensitive to noise, please consult the installer.
  • Design and specifications are subject to change without notice.

**** Contact office for compliance of this product : LG Electronics European Shared Service Center
B. V Krijgsman 1, 1186 DM Amstelveen, The Netherlands www.lg.com/global/business/ess

SIMPlIFIED EU DECLARATION OF CONFORMIRTY
Hereby, LG Electronics declares that the radio equipment type
PCS Unit is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
http://www.lg.com/global/support/cedoc/cedoc#
This device is a 2.4 GHz wideband transmission system, intended for use in all EU member states and EFTA countries.
For consideration of the user, this device should be installed and operated with a minimum distance of 20 cm between the device and the body.

Frequency Range 2412 – 2472 MHz
Output Power (Max.) 19 dBm
Software Version LG P2 02.00.01.00

MODELL
LG ESS Home 10 (D010KE1N211)
LG ESS Home 8 (D008KE1N211)https://www.lg.com/global/business/ess/business- resources/download
Copyright © 2019-2021 LG Electronics Inc. Alle Rechte vorbehalten.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LG User Manuals

Related Manuals