PENTAIR 185506 SuperMax High Performance Pool Pump User Manual
- June 9, 2024
- Pentair
Table of Contents
185506 SuperMax High Performance Pool Pump
User Manual
Electrical Installation
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This pump must be installed by
a licensed or certified electrician or a qualified service professional in
accordance with the National Electrical Code (NEC) and all other applicable
national or local codes and ordinances. Improper installation will create an
electrical hazard which could result in death or serious injury to users,
installers, or others due to electrical shock, and may also cause damage to
property.
Always disconnect power to the pump at the circuit breaker before servicing
the pump. Failure to do so could result in death or serious injury to service
people, users or others due to electric shock.
Read all servicing instructions before working on the pump.
Wiring
-
Be sure all electrical breakers, switches and automatic controls are turned off before wiring motor.
STORED CHARGE – Wait at least sixty (60) seconds before servicing. -
Become familiar with the wiring diagram, volts, hertz, amps and phase of your particular pump motor. All of this information is provided on the motor nameplate label found on the side of the motor.
-
Be sure that the supply voltage meets the requirements listed on the motor nameplate. If these requirements are not met, permanent motor damage may occur.
-
For wiring sizes and general guidelines for proper electrical installation, please follow the specifications defined in the National Electrical Code and all other applicable national or local codes.
-
3-Phase motors require external overload protection. An initial inspection is needed to ensure proper rotation of the pump.
Once installed, momentarily cycle the power on and then off. Note the rotation of the motor fan or shaft as it comes to a stop. If wired correctly the motor shaft and/or fan will match the rotation arrow noted on the pump. -
Use a strain relief and be sure all electrical connections are clean and tight.
-
Cut the wires to the appropriate length so they do not overlap or touch when connected.
Grounding
- Permanently ground the motor using the green ground screw, as shown below. Use the correct wire size and type specified by National Electrical Code. Be sure the ground wire is connected to an electrical service ground.
- The pump should be permanently connected to either a circuit breaker, 2-pole timer or 2-pole relay.
Note: If AC power is supplied by a GFCI circuit breaker, the pump should be wired on its own independent circuit unless the pump is operated in tandem with a Pentair salt chlorine generator.
Bonding
- Bond the motor to the structure in accordance with the National Electrical Code and all other applicable national or local codes. Use a solid copper bonding conductor not smaller than 8 AWG. For Canadian installations, a 6 AWG or larger solid copper bonding conductor is required. Run a wire from the external bonding screw or lug to the bonding structure.
- Connect the wire from the accessible bonding lug on the motor to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within 5 feet (1.52 meters) of the inside walls of the swimming pool, spa, or hot tub. Run a wire from the external bonding screw or lug to the bonding structure.
Before establishing or restoring power to the pump, be sure all electrical
connections are tight and all electrical and wiring compartment covers are
properly installed.
Note: When the pump is started and stopped by removing power with a relay
or timer, a two-pole device should be used to apply and remove power to both
POWER LINE TERMINALS.
Pentair offers GFCI breakers which offer appropriate personal protection while
meeting 2008 to current NEC Standards for Pool Pumps. See Pentair product
catalog for details.
-
DynaJet – TPE Series (S330)
-
DynaWave (S752)
-
Dyna-Pro (S771)
-
Flotec (FP243)
-
Utilitech (UT243 & UT950)
-
Challenger (355031)
-
Waterfall (355143)
-
WhisperFlo (071109)
- WhisperFloXF / Max-E-ProXF 1-Phase (352036)
- SuperFlo (350096)
- SuperMax (351096)
- Max-E-Pro (S691)
- WhisperFloXF / Max-E-ProXF 3-Phase (353076)
Section P/N 350486 Rev. B 6/7/17
Documents / Resources
|
PENTAIR 185506 SuperMax High Performance Pool
Pump
[pdf] User Manual
185506 SuperMax High Performance Pool Pump, 185506, SuperMax High Performance
Pool Pump, High Performance Pool Pump, Performance Pool Pump, Pool Pump, Pump
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>