SAFETY INFORMATION

Before connecting the relay module with a different device make sure that its parameters are consistent with the RM-16A module specification. Incorrect connection may cause undesirable action, excessive overheating and combustion hazard. To avert the hazard make sure that the relay module RM-16A is correctly connected. The connection of the device can be done only by a qualified installer who has up-to-date eligibility.

INTRODUCTION

Relay module RM-16A opens and closes the circuit in order to affect the work of other devices. Some uses of the module RM-16A with other Salus products are shown below:

  1. Connection of the thermostat with the voltage relay 230V (e.g. VS30/RT200/ERT20/ ERT30/ERT50/VS10) with a gas-fired boiler which requires free-voltage output NO/COM or NC/COM
  2. Connection of the SALUS thermostat with the NO/COM relay (e.g. 091FL) with the boiler control which needs NC/COM output (NC/COM output is normally required in the solid fuel boiler controls)
  3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A
  4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator.

PRODUCT SPECIFICATION

Power: 16A / 250V AC, 4000VA
INPUT NO/COM: Connection of a regulator with the free voltage relay NO/COM
OUTPUT NC/COM/NO: Output receiver
INPUT SL: Connection of the regulator with the voltage relay 230V
POWER SUPPLY N/L: Power of 230V AC/50Hz
Measurements: 47x47x21

VISUAL ASPECT

SALUS RM 16A Relay Module - VISUAL ASPECT

CONNECTION DIAGRAMS

  1. Connection of the thermostat with a voltage relay 230V (e.g. VS30 /RT200 /ERT20 / ERT30 / ERT50 /VS10) to a gas boiler which requires free-voltage output NO/COM.
    SALUS RM 16A Relay Module - CONNECTION DIAGRAMS

  2. Connection of the SALUS temperature regulator with NO/COM relay (e.g. 091FL) with a boiler control which requires NC/COM output ( NC/COM output is normally required in solid fuel boilers controls).
    SALUS RM 16A Relay Module - CONNECTION DIAGRAMS 2

  3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximuml electricity consumption of the receiver cannot exeed 16A
    SALUS RM 16A Relay Module - CONNECTION DIAGRAMS 3

  4. Connection of the devices other than electro thermal actuators with the wiring centre (KL06-M / KL08NSB / KL08RF / KL10 / KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator.
    SALUS RM 16A Relay Module - CONNECTION DIAGRAMS 4

mounting in a box Ø60 mounting only inside buldings

Relay module RM-16A opens and closes the circuit in order to affect the work of other devices. Some uses of the module RM-16A with other Salus products are shown below:

  1. Connection of the thermostat with the high voltage relay 230V (e.g. VS30 / RT200 /ERT20/ ERT30/ ERT50/ VS10) with a gas boiler which requires free-voltage output NO /COM or NC /COM
  2. Connection of the SALUS temperature regulator with the NO/COM relay (e.g. 091FL) with the boiler control which requires NC/COM output (NC/COM output is normally required in the solid fuel boiler controls )
  3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A
  4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/ KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead of a electro thermal actuator.

SALUS distributor:
OL Controls Sp. z o.o. Sp. k.
43-262 Kobielice, 4 Rolna St.
tel: +48 32 700 74 53,
e-mail: salus@salus-controls.pl,
www.salus-controls.euSALUS RM 16A Relay
Module - icon 4

Symbol meaning selecting electric electronic gear. Putting used gear with other waste products is strictly forbidden.
The declaration of compliance is on www.salus-controls.pl site
Made in Poland

Relay module SALUS Controls
Product code: RM-16A
The declaration of compliance is on www.salus-controls.pl site
Made in Poland
www.salus-controls.euSALUS
logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals