BEFORE YOU BEGIN

Read these instructions completely and carefully

WARNING

RISK OF ELECTRIC SHOCK

  • Turn power off before installation, inspection, cleaning or removal.

  • Do NOT make or break connections under load.

  • Follow appropriate lock out/tag out safety procedure.

  • Follow all National Electric Codes (NEC) and local codes.

  • This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation
    of the product and the hazards involved.

  • The installation and associated structures are subject to approval by the authority having jurisdiction.

  • Use only with components identified in this document.

  • Suitable for dry, damp, and wet locations; Do not immerse any component.

  • For commercial or industrial use only.

RISK OF FIRE

  • The luminaire shall be installed with a minimum of 5 inches between the light module and any highly reflective surface.
  • All cables including connectors shall not be concealed or extended through a wall, floor, ceiling, or other parts of the building structure; located above a suspended ceiling or dropped ceiling; permanently affixed to the building structure.
  • Cables shall be routed so that they are not subject to strain and are protected from physical damage; visible over their entire length; and used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions.
  • Before applying power, ensure that any open female connectors in the installation are sealed with an end cap.
  • For safe operation, and to maximize the longevity of the luminaire; ensure that the luminaire is clean and free of dirt, dust, oil, or any other debris. Do not apply any kind of film on the lens or otherwise cover the luminaire in any way.

Suitable for operation in an ambient temperature between 32°F (0°C) and 104°F (40°C).

Visit www.LED.com Call us today! 1-888-694-3533 Email us: horticulture.info@gecurrent.com

Typical Kit Components

Arize-HORT166-Integral-Intracanopy-LED-Lighting-
System-Instruction-fig-2

  1. Integral
  2. Leader cable with connector cap (accessory)
  3. Bracket (2X)
  4. Hook (2X) (accessory)
  5. Suspension cable (2X) (accessory)
  6. Paper ruler (fold carton using the outlines to create a triangle, then fold the tips into the designated holes

Light Module Specifications

  • SKU Part Number Description Weight
  • System Input
  • Current (A)
  • IEC 62471
  • Risk Group
  • 93150990 GEHI-HPPR-8S7N-1 LV Integral PPR, HE 8 foot, GL-LV, Non-dim 2.5 Kg
  • (5.5 lbs)
  • 120/208/277VAC,
  • 0.85/0.49/0.39A RG1
  • 93151001 GEHI-HPPR-8S8N-1 HV Integral PPR, HE 8 foot, GL-HV, Non-dim 2.5 Kg
  • (5.5 lbs)
  • 277/347/480VAC,
  • 0.36/0.28/0.20A RG1

Interconnection Cable Specifications

  • SKU Part Number Description
  • 93151002 GECA60E14-OR22B Integral Leader cable 6.5 m/21.3 ft, UL
  • 93151003 GECA60E14-GR08B Integral Jumper cable 2.4 m/7.87 ft
  • 93151004 GECA60E14-GR02B Integral Jumper cable 0.6 m/1.96 ft
  • 93151005 GECA60E14-GS02B Integral Y-splitter cable 0.6 m/1.96 ft
  • 93151006 GECA60E14-DR06B Integral Jumper cable 1.8 m/5.9 ft, Wieland to LLT (Wieland is 3 pin)
  • 93151008 GECA60FNA-NT00B Cap for female connector
  • 93152175 GECA60C14-8R06B Leader cable, 6 ft, M25 to Nema L8-20P, UL
  • 93152176 GECA60C14-7R06B Leader cable, 6 ft, M25 to Nema L7-15P, NA
  • 93152177 GECA60C14-5R06B Leader cable, 6 ft, M25 to Nema 5-15P, NA

Mounting Accessories Specifications

  • SKU Part Number Description
  • 93151009 GEMB-CBH3 Suspension cable, 6.7 m/22 ft, adjustable end loop
  • 93151010 GEMB-WAT3 Hook, wire form, 138 mm/5.43″
  • 93151011 GEMB-WAT4 Hook, wire form, 238 mm/9.37″
  • 93151012 GEMB-WAT5 Bracket, wire form, 58 mm/2.2 in diameter

CAUTION

Installation instructions and specifications for accessories can be found in the accessory package.

Sample Base Installation Diagram

Arize-HORT166-Integral-Intracanopy-LED-Lighting-System-Instruction-
fig-3

Wiring Diagrams

Arize-HORT166-Integral-Intracanopy-LED-Lighting-System-Instruction-
fig-4

Install Integral Bracket

  1. Put bracket on Inegral and push to lock.
  2. Slide brackets to end cap.
  3. Check orientation.

One-layer Installation to the Mounting Unistrut

  1. Wrap loop end of cable over structural member, insert gripper end through loop end.
  2. Use paper ruler gauge to ensure uniform spacing between suspension cables.
  3. Attach a hook to each end bracket.
  4. Attach hooks to suspension cables. Adjust the height of gripper end to make sure the Integral is horizontal after installation.
  5. Hang Integral on suspension cables with male connector facing leader power cable.
  6. Repeat steps 3-5 for remaining Integrals. Connect modules together with jumper cable and ensure the male and female connectors are snapped together correctly.

CAUTION: Do not exceed the maximum run length specified in the Maximum Loading table (left).

Maximum Loading of IntegralArize-HORT166-Integral-Intracanopy-LED-
Lighting-System-Instruction-fig-14

Electrical Connections

WARNING

RISK OF ELECTRIC SHOCK OR PRODUCT DAMAGE Turn power OFF before inspection, installation or removal.

Connect AC Input Leader Cable to Integral

  1. Rotate and remove the connector cap from the leader cable.
  2. Align keying features of the male connector on the 1st Integral with female connector on leader cable.
  3. Push connectors together until a click is heard.
  4. Recommended: secure AC input leader cable.
  5. Put connector cap on the female connector of the last Integral in each chain. Rotate the cap and make sure the cap is installed to female connector to comply to IP66.

NOTE: To disassemble connectors, rotate blue ring and pull to separate connectors.

NOTE: Relieve the stress from the cable connections by introducing a loop and using cable ties. The lowest point of the power cable should be just below the lowest point of the male connector.Arize-HORT166-Integral-Intracanopy-
LED-Lighting-System-Instruction-fig-21

Connecting to AC Line

Leader Cable with Open WireArize-HORT166-Integral-Intracanopy-LED-
Lighting-System-Instruction-fig-22

Connect the black wire to Line 1 and white wires to Neutral or Line 2 of the incoming AC line either within a suitable junction box or raceway provided with a suitable strain relief; or by means of a suitably rated plug to a receptacle.

Leader Cable with NEMA Plug

Leader Cable with Wieland Connector

Configuration When a Central Power Supply is UsedArize-HORT166-Integral-
Intracanopy-LED-Lighting-System-Instruction-fig-25

Install the left and right Integral line with their own suspension cables and separate power cables. The horizontal distance between the first suspension cables of both Integral lines must be 180 mm. Follow all previous applicable steps to build and complete both Integral lines.

Two-layer Installation

Arize-HORT166-Integral-Intracanopy-LED-Lighting-System-Instruction-
fig-26

When mounting a second Integral line below the first line, attach hooks to the bottom of the upper line bracket and the top of the lower line bracket. The vertical center to center distance between lines may be customized by choosing different combinations of mounting hooks. Follow all previous applicable steps to build and complete second Integral line.

NOTE: No more than two lines of Integrals may be suspended from a suspension cable.

  • Hook Option 1 Hook Option 2 Distance between Integral
  • lines (center to center)
  • Hook 1 (138 mm/5.43″) Hook 1 (138 mm/5.43″) 400 mm (15.74″)
  • Hook 1 (138 mm/5.43″) Hook 2 (238 mm/9.37″) 500 mm (19.68″)
  • Hook 2 (238 mm/9.37″) Hook 2 (238 mm/9.37″) 600 mm (23.62″)

Save These Instructions

  • Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
  • This device complies with part 15 of the

FCC Rules

  • Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This Class [A] RFLD complies with the Canadian standard ICES-005. /CeDEFR de la classe [A] est conforme à la NMB-005 du Canada. Electrical products must not be thrown out with domestic waste. They must be taken to a communal collecting point for environmentally friendly disposal in accordance with local regulations. Contact your local authorities or stockist for advice on recycling. The packaging material is recyclable. Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable material collection-service.