LA CROSSE TECHNOLOGY LTV-WL1 Spot Water Leak Sensor User Manual

June 9, 2024
LA CROSSE TECHNOLOGY

LA CROSSE TECHNOLOGY LTV-WL1 Spot Water Leak Sensor

LA-CROSSE-TECHNOLOGY-LTV-WL1-Spot-Water-Leak-Sensor-User-Manual-
product

SPOT WATER LEAK SENSOR

LA-CROSSE-TECHNOLOGY-LTV-WL1-Spot-Water-Leak-
Sensor-User-Manual-fig-1

REMOTE MONITORING WITH WIFI
Benefits of connecting your sensor to the La Crosse View™ app

  •  When the sensor is connected to the La Crosse View app, you’ll have access to its status anywhere on the go.
  •  You can even set up alerts that will send you push notifications for when water is detected, when water is no longer detected, the connection is lost, or when the sensor’s batteries are low.
  •  This information can also easily be shared with friends and family.

POWER & LED LIGHT COLORS

Power

  1.  Remove the front cover by twisting it counterclockwise to the unlock position.
  2.  Insert 2 fresh AA batteries according to the polarity markings. The LED light will flash blue when batteries are inserted.
  3.  Replace the front cover and turn clockwise to the locked position.

LED Colors
BLUE LED: Normal Transmission. The LED light will occasionally flash blue, indicating it is still transmitting correctly and that no water has been detected. Press the TX button inside the front cover to force transmission at any time.
RED LED: Water detected. The LED light will flash red twice every 5 seconds until dry. When water is no longer detected, the light will reduce in frequency and revert back to flashing blue to indicate transmission.
PURPLE LED: Battery is low. When the batteries need to be replaced, the LED light will flash purple 5 times every 30 seconds. (Purple) will flash once every second for 5 seconds.

POSITIONING

  •  The sensor will work best when simply placed on a floor. It will begin to detect water at 0.031 inches (0.787mm).
  •  If the sensor is placed vertically (Ex: hung inside a sump pump) the depth of the water needs to be at least 0.25 inches (6.35mm) high to trigger the sensor.

IMPORTANT: The metal contacts on the sensor should not be in contact with other metals. This will cause false WET readings and may damage the sensor.

SENSOR ID

La Crosse View™ Compatible
There is a Device ID and bar code located under the front cover. This ID is recognized by the La Crosse View app for users with an existing La Crosse

View compatible system
To add this sensor to your existing La Crosse View™ compatible system

  1.  Open your La Crosse View™ app to add sensors.
  2.  From Main Menu – select “Devices” under “Add/Edit”
  3.  On Devices page – select “ADD DEVICE”
  4.  Scan Device ID – Scan the bar code on your sensor or press inside the Device ID search box to enter your code manually. Once entered, select “Search”.
  5.  On Confirm Device page – Confirm the sensor image and model number are correct and select “YES”.
  6.  On Enter Device and Location Names page – Enter Device Name and select a location or enter  Location Name for your sensor. Select “DONE”.
  7.  You will now be prompted to add a water alert. Select “Add Alert” to add the alert right away or select “Later” to add at a later

Note: This sensor cannot connect to the La Crosse View app without a La Crosse View compatible station. Station’s that are La Crosse View compatible have built-in Wi-Fi capabilities that send your sensor’s data to the La Crosse View app. For more information about our new connected stations visit: http://bit.ly/LaCrosseViewconnected

CARE + MAINTENANCE

  •  Do not mix old and new batteries.
  •  Do not mix Alkaline, Lithium, standard, or rechargeable batteries.
  •  Always purchase the correct size and grade of battery most suitable for intended use,
  •  Clean the battery contacts and also those of the device prior to battery installation.
  •  Ensure the batteries have with correct polarity (+ / -).
  •  Remove batteries from equipment that will not to be used for an extended period.
  •  Promptly remove expired batteries.

SPECIFICATIONS

  • Temperature Range: -40°C to 60°C (-40°F to 140°F)
  • Transmission Range: Up to 400 feet (121 meters) in the open air, RF 915 MHz
  • Update Intervals: Samples every minute. Updates immediately if changes. Updates every 3 minutes if no change.
  • LED Lights: Blue-Normal transmission-No water detected Red- Water detected-flashes twice every 5 seconds Purple-Low battery-flashes 5 times every 30 seconds
  • Batteries: 2-AA, IEC, LR6 batteries (not included) Battery
  • Life: over 24 months with reputable batteriesLA-CROSSE-TECHNOLOGY-LTV-WL1-Spot-Water-Leak-Sensor-User-Manual-fig-3

CALIFORNIA RESIDENTS

This product can expose you to chemicals including acrylonitrile, butadiene, and styrene, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to: www.P65Warnings.ca.gov

WARRANTY & PATENTS
La Crosse Technology, Ltd. provides a 1-year limited time warranty (from the date of purchase) on this product, relating to manufacturing defects in materials and workmanship.

Warranty
www.lacrossetechnology.com/pages/warranty

FCC STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and the receiver.
  •  Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  •  Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions

  1.  This device may not cause harmful interference, and
  2.  This device must accept any interference received, including interference that may cause undesired operation.

Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LA CROSSE TECHNOLOGY User Manuals

Related Manuals