U-PROX Wireless Water Leak Detector User Manual

June 9, 2024
U-PROX

www.u-prox.systems support@u-prox.systems www.u-prox.systems/doc_water

WIRELESS WATER LEAK DETECTOR
Is a part of the U-Prox security alarm system
User manual
Manufacturer: Integrated Technical Vision Ltd. Vasyl Lypkivsky str. 1, 03035, Kyiv, Ukraine

Wireless Water Leak Detector

U-Prox Water – is a wireless detector which is designed to detect water leakage. The device sends an alarm notification to the
U-Prox control panel.
No installation required, for indoor use only.

The device is connected to the control panel and is configured with the U-Prox Installer mobile application.

https://u-prox.systems/Installer

Functional parts of the device (see picture)

  1. Top view of the detector case
  2. LED indicator
  3. Bottom view of the detector case
  4. On/off button
  5. Sensor contacts

TECHNICAL SPECIFICATIONS

Number of contacts 4
Power 3V, two AAA (FR03) lithium batteries included
Service life of battery up to 5 years
Radio frequency ISM-band wireless interface with several channels

ITU region 1 (EU, UA):   868.0 to 868.6 MHz, bandwidth 100kHz, 20 mW max., up to 4800m (in line of sight)
ITU region 3 (AU): 916.5 to 917 MHz, bandwidth 100kHz, 20 mW max., up to 4800m (in line of sight)
Communication| Secure two way communication,
sabotage detection, key – 256 bits
Dimensions & weight| 0°C to +55°C
Operating temperature range| 67,5 х 67 х 18 mm  &  55 grams
Case colour| white, black
Protection class| IP65

COMPLETE SET

1. U-Prox Water; 2. Two AAA FR03 batteries (pre-installed);
3. Quick start guide

CAUTION. RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE USED BATTERIES ACCORDING TO THE NATIONAL REGULATIONS
Do not use salt batteries (R03)! FR03 lithium batteries are highly recommended. Usage of alkaline batteries (LR03) allowed only at temperatures above +5°C.

WARRANTY

Warranty for U-Prox devices (except batteries) is valid for two years after the purchase date.
If the device operates incorrectly, please contact support@u-prox.systems at first, maybe it can be solved remotely.

REGISTRATION

RANGE TEST FOR OPTIMAL INSTALLATION LOCATION

Due to Grade 2 requirement RF link works with reduction of power in 8 dB

INDICATION IN RANGE TEST MODE

INSTALLATION

No installation required, just put the sensor on the floor

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>