USE AND CARE GUIDE

12” PLASMA UNIVERSAL CEILING MOUNT

PACKAGE CONTENTS
Part Description Quantity
A Fixture 1
B Screw 2
C Wire Nut 5

SILENTAIRE-559051000-12-Inch-Plasma-Universal-Ceiling-
Mount-02 SILENTAIRE-559051000-12-Inch-Plasma-Universal-Ceiling-
Mount-03 NOTE: Keep your receipt and these instructions for proof of purchase.

NOTE: Dispose used products according to local regulation.

WARNING: Shut off the power at the circuit breaker or fuse panel before removing
the old fixture, ballast, or fluorescent tubes. If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.

WARNING: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker before removing the existing light fixture or installing the new one. With power disconnected
to your electrical box, remove the existing fixture. Make a sketch of how the current fixture is wired (by wire color) or mark the wires with masking tape and a pencil so you will know how to properly reconnect the wires to the new LED light fixture.

INSTALLATION

Select a suitable location that can support the weight of the fixture. Determine the method of mounting before drilling.

RISK OF ELECTRIC SHOCK – These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

  1. Unscrew the screws to take out the cover plate.

  2. Pass the power input line through the middle hole of the fixture,
    **STAND ALONE MODULE WIRING WITHOUT LIGHT

  3. a

    • Connect the black wire from the fixture body to the black wire
    • Connect the white wire from the fixture body to the white wire from the junction box.
    • Cover the ground wire by wire nuts.
    • Cap Red and White wires and leave inside. These are only for light fixtures.
  • 4a Tighten the screws to fix the cover plate on the fixture.
CONNECTING WITH LIGHT FIXTURE WIRING
  • 3b • Repeat above stand alone black and white wiring to junction box.
    Connect the red wire (L’) from the fixture body to the black wire from the other light fixture ( not included ) .
    Connect the white wire (N’) from the fixture body to the white wire from the other light fixture ( not included ) .
    Connect the ground wire from the fixture body to the ground wire from the junction box.

  • 4b Tighen the screws (B) to fix the other light fixture (not included) on the fixture (A). Tighen the cover on the light fixture.

  • 5 Restore power to the electrical box. Turn the light switch on to activate the fixture.

  • 6 When the air volume of the air outlet becomes small, remove the dust covers on both sides, clean the dust on the net, and then install it as it is.

SELECTING WORKING MODE
This flush mount allows you to choose between two working modes by using your wall switch and flipping it on/off/on within 3 seconds.

TO TURN ON WHOLE SYSTEM: Turn on the light switch to activate the light fixture, with green indicator light and sterilization mode by fan running on low speed.

TO TURN ON STERILIZATION MODE ONLY: Turn off the main down light by wall switch, and turn back on within 3 seconds to activate sterilization  mode only by fan running on high speed.

CAUTION: HIGH VOLTAGE. DO NOT CONNECT WITH LED CEILING FAN.

CAUTION: This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that may result in flashover or a risk of fire. The 8 hr TWA Ozone for this product is 0.015 ppmv when tested in a 30 m3 chamber.

WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or other injuries which could be hazardous or even fatal.

  • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
  • SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 45°C.
  • SUITABLE FOR DAMP LOCATIONS.
  • MINIMUM 90°C SUPPLY CONDUCTORS.
  • CAUTION-RISK OF SHOCK.
  • DISCONNECT POWER BEFORE SERVICING. STORE IN AMBIENT NOT EXCEEDING 45°C.

NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, and consult the dealer or an experienced radio/TV. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

MAINTENANCE: See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.

Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. – 5 p.m., CST, Monday – Friday
1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com