Pathway 0700-5481 PWGW DIN CLK Vignette Clock Installation Guide

June 3, 2024
Pathway

Pathway 0700-5481 PWGW DIN CLK Vignette Clock Installation Guide
Pathway 0700-5481 PWGW DIN CLK Vignette Clock

OVERVIEW

Vignette Clock is a time-based playback device that allows you to automate snapshot playback as well as other Vignette functions such as zones, grandmaster level, release all, and others according to date, time, or astronomical events such as sunrise or sunset.

The device mounts to 35mm DIN rail and is simple and easy to install. Configuration is done with the free Pathscape software, available for download from the Pathway Connectivity website.

CONNECTIONS

Make the following connections, WITH THE POWER TURNED OFF.

POWER
Vignette Clock must be supplied 24-48 VDC. Connect a suitable power supply to the green DC POWER jack. Ensure correct polarity is observed when wiring the included terminal plug. Alternatively, connect the device to a PoE switch.

NETWORK
Connect the device to a switch connected to the lighting network using a Cat5/6 Ethernet cable. Ensure the network is set up correctly with the same subnet and IP range as other Vignette stations from which you wish to trigger playback. See the Pathscape manual for proper IP configuration.

STATUS INDICATORS

STATUS
A blue heartbeat indicates processor is running;
off indicates no power.
When Identifying, the LED will flash white at 1 Hz.

RJ45 LEDs
The RJ45 Ethernet jack has two green LEDs.
One will glow steady when the link is up and the other will flash with activity.

Overview

INSTALLATION

  • Disconnect all power before proceeding with installation.

  • Securely mount DIN rail (if not already installed in an enclosure).
    To mount the Vignette Clock, hook the upper slots on the back of the plastic extrusion to the DIN rail and then gently but firmly press on the bottom front corners of the extrusion to snap the module onto the rail. DO NOT press directly on the PCB card itself.

  • If the Vignette Clock is using an auxiliary power supply, connect the power IN terminal block, after checking that polarity is being observed. The earth ground terminal must be connected to the enclosure’s chassis or electrical ground terminal to ensure EMC compliance. Restore power and the card will boot up.

  • Attach the network cable to the RJ45 connector. Because good wiring practice requires building wire to terminate with a female connector, typically a short (12”/30cm) male-to-male jumper is used. If PoE is being used, the card will boot up. Both auxiliary power and PoE may be connected simultaneously without damaging the Clock.

  • The STATUS LED will begin flashing blue. Ensure the RJ45 LEDs indicate link and activity. The system is now ready for testing.

  • To remove the device from the DIN rail, use a flathead screwdriver to gently pry the hooked foot on the end caps of the device away from the DIN rail. The corner of the device should life free; repeat at the other side and unhook the device from the rail.

  • On a computer on the same network, open Pathscape. Refer to the Pathscape manual on how to read settings and set properties.

  • YOU MUST USE Pathscape software to add the device to a Security Domain and enable Unsecured Protocols if needed (see Pathscape manual for details on Security, and Vignette
    Properties > Network DMX Receive Protocols).

  • For all other configuration details, see the Pathscape Manual section Vignette Clock.

IMPORTANT – UNSCURED NETWORK PROTOCOLS

Due to new cybersecurity laws, all Vignette devices shipped after January 1, 2020 have security properties enabled. This means that by default, the device is not set up to receive unsecured network protocols such as E1.31 sACN.

You must add the Pathport to a Security Domain using Pathscape before configuration and use.

Pathway ssACN (Secure sACN) is enabled by default.

To use the above unsecured protocols, open Pathscape. In the Pathport base device properties, under the Network DMX Receive Protocols section, click the Allow Unsecured RX checkbox.

UNSCURED NETWORK PROTOCOLS

Once checked, you may select the network protocol(s) to receive.

UNSCURED NETWORK PROTOCOLS

For further information, please see the following sections in the Pathscape manual: Security, Vignette Properties > Network DMX Receive Protocols.

ELECTRICAL INFORMATION

  • Powered via PoE (PoE Class 1 device) or regulated 24 48VDC power supply
  • 4W maximum power consumption
  • Internal, replaceable CR2032 backup battery (3V)

COMPLIANCE

  • ANSI E1.31 sACN – Streaming ACN
  • IEEE 802.3af Class 1 Power-over-Ethernet
  • RoHS 2011/65/EU + A1 2015/863
  • CE
  • California Title 1.81.26, Security of Connected Devices

PHYSICAL

  • 0.35 lbs (0.16 kg)
  • 4.5”W x 4”H x 1.9” D (114mm x 103mm x 49mm)
  • Operating Conditions: 14°F-113°F (-10°C to 45°C); 5-95% relative humidity, non-condensing.

© 2021 Acuity Brands, Inc. • One Lithonia Way, Conyers GA 30012
Pathway Connectivity | #103 – 1439 17th Ave SE Calgary, AB Canada T2G 1J9 Phone: + 1 866 617 3074 www.pathwayconnect.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals