HAVACO RKV-450 5500 T Roof Type Radial Fans with Vertical Air Discharge User Manual

June 4, 2024
HAVACO

HAVACO logo

RKV-450 5500 T Roof Type Radial Fans with Vertical Air Discharge
User Manual
HAVACO RKV 450 5500 T Roof Type Radial Fans with Vertical Air
Discharge

RKV-450 5500 T Roof Type Radial Fans with Vertical Air Discharge

WENTYLATORY DACHOWE Z PIONOWYM WYRZUTEM POWIETRZA ROOF TYPE RADIAL FANS WITH VERTICAL AIR DISCHARGE
USER’S MANUAL AND TERMS OF WARRANTY

HAVACO RKV 450 5500 T Roof Type Radial Fans with Vertical Air
Discharge

RKV-315/2000 M
RKV-355/3000 M
RKV-400/4000 M
RKV-315/2000 T
RKV-355/3000 T| RKV-400/4000 T
RKV-450/5500 T
RKV-500/7500 T
RKV-560/10000 T
---|---

SAFETY WARNINGS

  • Fans contain rotating parts and electrical connections. Therefore, pay attention to safety warnings during their installation, maintenance, and operation.
  • Electrical connections must be carried out by qualified electricians, according to the attached wiring diagrams.
  • During transport, installation, and maintenance, hands should be protected with gloves.
  • Do not use the product at ambient temperature over 40 °C.
  • The fan is capable of carrying air at a temperature max 120 °C

TRANSPORTATION

  • The fan should be kept in the original package in a vibration-free, dust-free environment, away from aggressive substances until it’s delivered to the installation site.
  • The fan should be checked for any damage that may originate during transport – check if the impeller rotates free of friction.
  • Eventual damaged revealed must be communicated to the carrier and proper protocol should be made, specifying the type of damage.

INSTALLATION

  • Power supply, current, and frequency values shall comply with the product label.
  • Use elastic connectors to prevent transmitting the unit vibrations onto the installation.
  • The fan can be mounted in any position.
  • Check if the impeller rotates in the correct direction.
  • Check if consumption – Intensity I(A) – does not exceed the maximum value, indicated on the fan nameplate.
  • Do not use the fan in an area in which flammable gasses and acidic or corrosive substances are present, as it may cause irreversible damage to the fan.
  1. RKV Fan
  2. Sealing gasket
  3. Roof base
  4. Roof

WIRING DIAGRAM

 TECHNICAL DRAWING

Wymiary

HAVACO RKV 450 5500 T Roof Type Radial Fans with Vertical Air Discharge -
DRAWING

Typ A B C D E F G H I
RKV-315/2000 845 740 185 700 550 395 576 14 35
--- --- --- --- --- --- --- --- --- ---
RKV-355/3000 845 740 235 700 550 395 576 14 35
RKV-400/4000 895 780 270 750 585 430 576 14 35
RKV-450/5500 960 855 282 800 595 440 625 14 35
RKV-500/7500 1030 915 320 850 695 490 675 14 35
RKV-560/10000 1195 960 360 950 820 610 740 14 35

TECHNICAL DATA

Typ m3/h [rpm] [kW] [A] [V] [Hz] [µF] [dB(A)] Klasa IP [kg]
RKV-315/2000 M 1900 1380 0,25 2,1 230 50 10 48-40 F 55 22
--- --- --- --- --- --- --- --- --- --- --- ---
RKV-355/3000 M 2850 1380 0,25 2,1 230 50 10 50-42 F 55 27
RKV-400/4000 M 4000 1390 0,37 3,4 230 50 15 51-43 F 55 33
RKV-315/2000 T 1900 1380 0,25 0,87 400 50 48-40 F 55 22
RKV-355/3000 T 2850 1380 0,25 0,87 400 50 50-42 F 55 27
RKV-400/4000 T 4000 1390 0,37 1,2 400 50 51-43 F 55 33
RKV-450/5500 T 5300 1365 0,55 1,6 400 50 54-46 F 55 38
RKV-500/7500 T 8000 1410 1,1 2,6 400 50 56-48 F 55 49
RKV-560/10000 T 10500 1420 2,2 4,9 400 50 65-57 F 55 58

CLEANING AND MAINTENANCE

  • Maintenance and cleaning of the product should be carried out by qualifiedlifstaff.
  • Before cleaning or maintenance disconnect the fan from the mains supply.
  • All electrical connections should be regularly controlled – any worn out or damaged cables should be replaced.
  • Periodic maintenance should be carried out at least once every six months to prevent dust accumulation which may cause the lower performance of the fan, and unbalance of the impeller which may greatly reduce the lifespan of the unit.
  • Clean the fan with a soft brush or damp cloth. Do not use inflammable or combustible cleaners.
  • While cleaning the impeller pay attention to protecting the balance weights.
  • Bolts that might become loose during operation should be checked.

Wyłączny przedstawiciel na terenie Polski
Ventia Sp. z o.o.
ul. Słowikowskiego 81
tel.: (+48 22) 841 11 65
fax: (+48 22) 841 10 98
e-mail: info@ventia.pl
05-090 Raszyn
www.ventia.pl