Betteri BC01 3 Pin AC Connector for PV System Instruction Manual
- June 3, 2024
- Betteri
Table of Contents
Betteri BC01 3 Pin AC Connector for PV System
Introduction
Dear Customer, Thank you for choosing our product “ Multi-pole AC Connectors For PV system”, which are referred to as “Connectors” hereinafter. Please read this instruction book carefully in order to use the product correctly, quickly and safely.
Application & Structure
The connectors are specialized for the connection of inverter equipment in
terrestrial PV systems;
The connection of pin and wire is screw type which is easy for field
installation and the connection of the male and the female connector is snap-
fit type;
Easy operation, reliable performance on mechanical and electrical properties;
The connector may be used in other areas and industries; we will not assume any unstated quality responsibility if the product is used in other fields and industries.
Product Outline Size
-
Outline of male cable connector (2+PE):
-
Outline of female cable connector (2+PE)
Type
BC01(CC) Connector type:BC01(CC)
Male cable connector type:
TUV, CSA: 250V 25A | BC01-3M22-15 |
---|---|
CSA: 350V 25A | BC01-3M32-15 |
Female cable connector type:
TUV, CSA: 250V 25A | BC01-3F22-15 |
---|---|
CSA: 350V 25A | BC01-3F32-15 |
Main Technical Features
Item | Parameter | Item | Parameter | |
---|---|---|---|---|
Applicable environment temperature | -40℃~+85℃ | Over-voltage category | III | |
Relative humidity | ≤95% | Wiring Connection | Screw type | |
electrode number | 2P+PE | Insulation resistance | ≥100MΩ | |
Rated voltage | TUV: 250V AC CSA: 350V AC | Rated impulse withstand voltage |
4000V AC
Rated current| 25A(4mm²)| Degree of protection| IP68(1.5m,24h)
Material of pin| Copper alloy &silver plated| Insertion and withdraw
force(unlocked)| 10~50N
Contact resistance| ≤1mΩ| Applicable wire gauge| 2.5/4.0mm2
Pollution degree| 2| Outer cable diameter| 10~13mm
Enclosure flame class| UL94-V0| Standards| UL6703A EN 61535
PPP 59015A:2013
Safety Precautions
Please be careful during loading, unloading and transportation. Avoid outer
heavy pressure to protect connectors;
If the internal parts do not match the instructions after opening the package,
please stop using it immediately and contact sales or our company directly;
Please ensure the inverter system is not under working conditions firstly when
installing connectors, The human body cannot simultaneously contact the
connector’s positive and negative pole , in order to avoid electric shock
accidents;
The operator who installs or maintains the product shall be trained and have
related electrical installation and maintenance skill.
For Assembly
Tools
-
Wire striper
-
Flat screwdriver and #1 cross screwdriver
-
Monkey wrench wider than 3cm and 30# solid wrench
Strip cables
Only multiple strands of copper wire can be used. Please cut and strip the
wire according to the requirements, and the ground wire needs to be 5mm longer
than live and naught wire, and the applicable stripping length is 7 ~ 8mm.
Instruction of cable connector assembly
Screwing off the tail parts (End Locker, Wire Sealing Claw and Wire Sealing )
from male or female cable connector and then pulling the wire which was cut
and stripped through them in turn.
Crimp the wire
Inserting the stripped wires correctly into the corresponding pin holes
according to the identification and then tightening all screws firmly, Screw
twisting torque 0.4±0.1N·m. after it , giving a reverse pull force lightly (
about 10N by manual to test crimping result. Please pay attention to avoiding
damage of pins and pin-holder. After crimping, The tensile strength shall meet
the requirements listed in the following table:
Conductor cross-section area (mm2) | Required tensile strength (N) |
---|---|
2.5 | >50 |
4.0 | >60 |
Install male & female cable body to plastic housing
Push the male or female cable body into housing body correctly according to
the position of the clamping groove , and will hear a crisp “click” sound in
place.
Push the sealing body and sealing craw into the housing body, and then tighten
the end locker, torque 4.0±0.5N·m.
Instructions of Operation
Please switch off the system power and ensure the male and female connector
are of the same type before using;
When mating connectors, align mate-locker on the male connector with grooves
on the female connector, and insert gradually .Connected in place, there will
be a sound of “click”;
If the connectors are separated, choose a corresponding flat screwdriver to
push mate-locker step slightly out of position, and then give a force along
the axial direction until separation.
If the connector to be disassembly for rewire, please according to the
following steps:
Loosen tail parts (End Locker, Wire Sealing Claw and Wire Sealing body);
Use a suitable flat screwdriver to press the elastic tongue on the male or
female cable body inward and push forward slightly, and when the tongue comes
off a little, use the same method to the tongue on other side. Give a force
along the axial direction until separation.
Maintenance
The user should do maintenance work according to the different operating environments and frequencies. If discovering any damage of connector systems, please stop using and change it immediately. Please do not separate and mate the connector system frequently if not for repairing or maintenance reason which may reduce the waterproof performance of the system.
Statement
If this instruction is inconsistent with the received product, the received
product shall prevail. One instruction book will come with one standard box.
Please contact us or view our company’s website for downloading if you need
more copies. All technical data is for reference only when using the product.
Any commercial purpose application is forbidden. Wuxi Betteri Electronic
technology Co., Ltd. owns the copyright and the right of final interpretation.
Wuxi Betteri Electronic technology Co., Ltd. is entitled to conduct any
further modification to the print error, technical improvement and innovation
without prior notice, and all the translations shall be subject to Chinese
Edition.