Product Features

  1. Adopts MCU and advanced PID intelligent temperature control heating technology & advanced temperature measurement technology, make temperature exact.
  2. Special temperature correction function, it can improve the temperature measuring quality and measurement accuracy.
  3. Automatic parameter memory function, set and keep parameter easily.
  4. Intelligent fault detection function, remove the fault easily, save time and high efficient, ensure the stability and reliability.
  5. With time mode and continuous mode in order to meet different user
  6. Adopt imported high quality silicon controlled, with non-contact switch quick response, control precision, without the noise and low power consumption etc.
  7. With high-quality aluminum, using a integrated techniques combined with excellent machining process produced heating plate, high heating modulus, fast heating, heat even, keep shape at high temperature.
  8. Heating at bottom, especially suitable for LED industry aluminum base plate lamp bead welding repair, effectively avoid the traditional welding mode of high temperature on light bead damage, significantly extend the service life of bead
  9. Temperature control range can be suit for any electronic industry. Such as lead and lead-free PCB board preheat, welding Repair, sealing compound,
  10. Adhesive Dispense constant temperature heating and industrial industries constant temperature heating, sample roasting drying and other temperature test.
  11. Easy operate, can use machine skillfully after simple training .

Main Parameter

Working bench size 267mmx320mm
Rated voltage and frequency AC220-230/AC110V 60/ 50Hz
Whole machine power 800 W
Preheating plate size 180mmx240mm
Preheating plate temperature range 0-450°C

Packing list

Name

| Quantity
---|---

T-946 hot plate

|

1

Power line

|

1

Fuse

|

1

User manual

|

1

Cross-flow fan|

1

Main Parts

  1. Plate main body
    Plate main body

  2. Front panel
    Front panel

  3. Side panel
    Side panel

  4. Back panel
    Back panel

Instructions

This machine is with two working modes: time mode and continuous mode.

  1. The timing mode: user set the heating time, it will stop heating when time is up, then it give alarm. The continuous mode: The machine keeps heating unless the user close heating switch by hand.
  2. Mode setting and conversion: The green indicator light is the working mode status light . The green indicator light is bright if open the machine, press SET , the green indicator light turns off, press SET three times, the green indicator light is bright again, repeatedly operate according to this

The mode selection method


The green indicator light turn on, open the ‘WARM” switch| The machine is in the continuous mode
The green indicator light turn off, open the “WARM” switch| The machine is in the time mode

Press “▲” and “▼” adjust the temperature.
The machine need preheat firstly before use it.

Basic operation
  1. Check the power line
  2. Press”ON”,press “SET”, enter the parameters set interface.
  3. Set heating time( This time is only effective in timer mode, if the machine is in persist mode, can press “SET” two times, skip the settings)
    • Press “▲”up,“▼”down, adjust minutes to your number(0-99 minutes)
    • Press“SET”, set the seconds, turn seconds to your number(0-59 seconds)
  4. Set the heating plate working temperature After time setting, press “SET” again; change to temperature setting, the clock digital tube display “FF:FS”, as following:

Press “▲”up,“▼”down , adjust temperature to your number(0-450℃)

  1. Set work mode, start heating
    Time mode: Press “SET” several times, until the green indicator light power off, open the preheating switch (WARM), start heating. The red indicator light turn on, digital tube start timing.
    Continuous mode: Press “SET” several times, until the green indicator light turn on, open the preheating switch (WARM), start heating. The red indicator light turn on, digital tube start timing.

  2.  Stop heating
    Heating finished, turn off the heating switch(WARM), the red indicator light power off, the heating plate stop heating(if the machine is in time mode, until the time is up, the machine will stop heating automatically and the digital tube stop timing, the warning buzzer rang two times.)

  3. Cooling down
    Open cooling switch (COOL), cross-flow fan start working, until the temperature of heating plate drop to normal temperature, turn off the cooling switch (COOL).

  4. Power off
    Turn off the power switch(POWER),pull off the power line

SMD desoldering method
  1. According to the size of the PCB board and welding process requirement, set the machine work mode and heating plate output temperature.
  2. Open heating switch(WARM), heating plate start working, display temperature rise, until displayed temperature reach setting number, wait for a moment, make the heating plate panel temperature even.
  3. Put the PCB board on the heating plate, until the solder paste melt, take down the SMD with tweezers or vacuum pen.
  4. Work finished, take down the PCB board from heating plate, turn off the heating switch (WARM) and the power switch.
SMD soldering method
  1.  According to the size of the PCB board and welding process requirement, set the machine work mode and heating plate output temperature(Suggest setting in time heating condition, according to the experience setting time, which can effectively prevent PCB overly heating ).
  2. Open heating switch(WARM), heating plate start working, display temperature rise, until displayed temperature reach setting number, wait for a moment, make the heating plate panel temperature even.
  3. Put the PCB board on the heating plate.
  4. The time is up, the heating plate stop heating, check if solder paste is completely melted, if melting is not complete, adjust the timing time, and continue Until solder paste completely melted, take down the PCB board from heating plate. Until solder paste cool and curdle, soldering work finished. 5)Turn off and turn on the heating switch(WARM) each time, use the last setting parameters acquiescently, go to the next piece of PCB board soldering. 6) All the soldering finished, turn off the heating switch(WARM) and power switch.

Caution

  1. High temperature operation, pay attention to safety, avoid burning.
  2. Keep heating plate clean, clean with anhydrous alcohol regularly.
  3. If there are some tin slag on heating plate, clean it in molten state (Don’t use the blade or metal edge tool doctoring, in order to avoid the scratch heating plate).
  4. If there are some flux on heating plate, turn off the power switch. In nor mal temperature condition, put some cleanser on heating plate, until residue dissolved; use soft cloth to wipe gently. Use soft cloth with anhydrous alcohol wipe the heating plate.
  5. Long-time no use, should cramp out the power source plug!

Warranty

The mainbody maintains for one year and lifetime repair service. Long-term factory price supply for spare parts. Provides the immediate network online Q/A and the technical advisory work service

Statement

If any difference between user operating manual and actual product, take actual product as!

For Further Information, Please Visit: www.tech168.cn

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

puhui User Manuals

Related Manuals