SUNSYNK L051100-A Power Lite Lithium Battery System Owner’s Manual
- June 3, 2024
- SUNSYNK
Table of Contents
L051100-A Power Lite Lithium Battery System
Owner’s Manual
Introduction
Thank you for choosing Sunsilk’s energy storage system.
The energy storage module comprises of lithium ion rechargeable batteries with
5.12 kWh capacity, and the controller enables a central of multiple modules.
This manual provides information regarding safety precautions to prevent
possible accidents and how to use the product.
Please read this manual carefully before use for safety and keep this manual
handy for reference.
1.1. Main Features
Some main features of this product are:
-
Long Life Span
The battery can be expected to remain serviceable for more than 10 years, considering that it is charged and discharged once in a day at room temperature (25 deg. C). -
Long Life Span
Olivine-type lithium iron phosphate batteries with excellent thermal stability and storage characteristics are used in this product. The module also incorporates a self-monitoring function for the detection of any abnormalities in energy storage. -
Compact Design
The height is nicely designed in 3U, in favor of standard industrial applications. -
High Scalability
Multiple energy storage modules can be connected in parallel, and the capacity can be customized according to the intended use.
1.2. Safety Precautions
Sunsilk products are designed with full consideration of safety. However, all
electrical appliances can be dangerous if used inappropriately; it can cause a
fire or electric shock that leads to severe injury or death. For your
protection, please read these safety precautions thoroughly.
Definitions of Symbols:
Below are symbols used in this manual and the unit.
Please read through the following definitions before reading the manual.
Warning
If you ignore these instructions, it can lead to a fire or electric shock
causing serious injury or death.
Caution
If you ignore these instructions, it can lead to electric shock or other
accidents causing injury or harm to nearby products.
Warning
If you do not follow the instructions below, it can lead to a f ire or
electric shock causing serious injury or death.
Instruction
Use designated cable. A non-designated cable use can cause electric shock. Be
sure to use the cable designated in this manual.
Prohibited
Do not damage cables. If you damage a cable, it can cause a fire or electric
shock.
- Do not work over or damage a cable.
- Do not place heavy objects on a cable or pull the cable.
- Do not place a heater near the cable, which may result in the cable overheating.
- Do not tuck down a cable when installing in a rack.
- When you unplug a communication cable, be sure to hold the plug and pull it.
Instruction
Connect a power cable and communication cable properly.
- If you connect a power cable improperly, contact resistance will increase and it may damage the parts or cause a fire.
- Insert the connector of the communication cable all the way in. If it is connected improperly, the system may be deactivated.
Prohibited
Do not install in a closed area. If the module/controller is installed in a
closed area with no air-conditioning, heat may build up inside the set and
cause a fire.
Prohibited
Do not place the set in direct sunlight or near a heater. Doing so can cause
deformation, a breakdown, or a fire. Pay extra attention when you place the
set near windows.
Prohibited
Do not install the set where excessive oil smoke, steam, moisture or dust is
contained in the air. If the set is installed in such a place, it may cause a
fire or electric shock.
Instruction
- Wear insulating gloves and protection glasses during installation and connection
- Wear insulating gloves and protection glasses during installation and connection of the set to prevent electric shock or other injuries.
No Wet
- Do not allow water and/or foreign objects inside the module
- Water or foreign objects inside the module can cause a fire or electric shock.
- Should this occur, however, turn off the “POWER ON/OFF” switch on the controller to shut down, and remove the power connector from the POWER CONNECTOR terminal of the module.
Do not disassemble
Do not open the set unnecessarily. Opening and modifying the set can cause a
fire or electric shock.
Caution
If you ignore any of the following instructions, it can cause injury or damage
to nearby products.
Prohibited
Do not cover the vent. If the vent is covered, heat may build up inside the
set and cause a fire.
- Do not put the set in a poorly ventilated and narrow space.
- Remove any dust buildup in the vent.
- Do not place the set upside down or sideways.
- Do not place on a shag carpet or bed.
- Do not cover the vent with a cloth, etc.
Instruction
Install in a stable place.
- If you install the set in an unstable place, such as an unstable rack, it may fall and cause injury.
- Do not install upside down or sideways. The set may drop and cause injury.
Instruction
Use the designated packaging materials for transportation. If you do not use
the designated packaging materials, the packaging material may be damaged by
vibration during transportation and it may cause injury.
Instruction
Install based on the designated way of installation. If you do not follow the
designated way of installation, the set may drop due to the strength poverty
and can cause injury.
Instruction
Fix a rack to the floor. If a rack falls by the weight of the set, it may
cause serious injury or death.
No Wet
Do not touch with wet hands If you touch the set with wet hands, it may cause
electric shock.
Instruction
Install other equipment or accessories properly. If you inadequately install
other equipment or accessories sold separately, they may fall and cause
injury. When you install any of the following accessories, install it properly
based on this manual.
Bracket
Power connector
Instruction
Set up cables properly If your foot is caught by a cable, the set may fall and
cause injury. Connect and
install cables carefully.
Instruction
Power off at a malfunction In case any malfunction happens, please turn off
the POWER ON/OFF switch in order to shut down, and remove the power connector
from the POWER CONNECTOR terminal of the module.
Prohibited
Do not put anything, stand or sit on the set If you put anything on the set,
it may fall and cause injury.
Also, if it is used as a stool, for example, it may topple and cause injury.
Instruction
Follow related laws or ordinances for disposal. When you dispose of this
product, do not dispose as general or household waste.
Instruction
Disposal with specified method Contact technical vendor when you discard. Do
not disassemble, destroy, or disposal in the fire.
Danger
If liquid is leaking from the module, observe the following measures.
- Do not allow the liquid to come in contact with skin or clothing.
- If the liquid comes in contact with skin or clothing, wash thoroughly with plenty of water.
- If the liquid gets into the eyes or mouth, flush immediately with clean water, and immediately seek medical treatment.
- Contact customer service.
1.3. Precautions for Use
-
In the case of a failure, or any of the abnormalities shown below, turn off the set and contact Sunsynk customer services.
1. Abnormal sound, smell or smoke.
2. Water or particles inside the product.
3. The product is dropped, or the cabinet is damaged. -
Charge and discharge the product according to the control signals of the controller. Do not hammer a nail or punch a hole in the product.
-
Replace the module with a new one if discharge time at room temperature is noticeably short, even from fully charged.
DO NOT:
- Disassemble.
- Modify the product (Modification may destroy the protection function inside, or cause abnormal charge/ discharge, heat generation, gas eruption, or fire.).
- Touch the rear output terminal except for installation.
- Throw the product into fire or heat, or otherwise expose the set to heat or naked flame.
- Submerge the product in liquid or allow it to become wet.
- Apply strong shock, crush, or drop.
- Use for medical purposes.
- Place any foreign objects inside.
- Connect any devices that exceed the operating voltage and current range.
- Do not unplug the power connector from the POWER CONNECTOR terminal while power is turned on.
Specification and Functions
2.1. System Introduction
L051100-A Energy Storage System is consisted of 2 sets of M025100-A modules
manufactured by Sunsynk. In each M025100-A, there are 8 pcs of 100 Ah LFP cell
originated from CATL. The overall system also provides standard communication
port, i.e. CAN and RS485, to monitor the working status and communicate with
upper machine as well as the Power Conversion System (PCS) in front. The
system schematic drawing is presented in Figure 1.
2.2. Dimensions
L051100-A dimensions are presented in Figure 2. It is well designed for 19
inch cabinet.
2.3. Specifications
pacifications of L051100-A
Cell Type| LiFePO4 (LFP)
Rated Voltage| 51.2 V
Rated Capacity| 100Ah
Rated Energy| 5.12kwh
Packing| 1P16S
Working Voltage Range| 44.8~57.6V
Standard Charging Current| 50A
Max. Continuous Charging Current| 50A
Standard Discharging Current| 50A
Max. Continuous Discharging Current| 100A(1C, 25 ±2°C)
Max. Pulse Discharging Current| 200A(2C, 30S, 25°C ±2°C SOC≥40%)
Standard Charging Method| 0.5C CC to 57.6V, CV at 57.6V till current is 0.05C
Working Temp.| Charging: 0° ~50 Discharging: -20°C~55°C
Working ROH| 20%~80%
Storage Temp.| -20~50°C
Self-discharging rate| ≤5%(25 , 50% SoC)
---|---
SoC @ end of product line| 40%
Insulation Resistance| >100MΩ
Voltage Difference in each module| ≤20mV
Inner Resistance of single Cell| 0.34±0.05mΩ(fresh cell 30~40% SoC)
Weight| Approx. 48kg
Dimension| 440mm530mm132mm(not include connector MSD and other parts)
2.4. Installing Instructions
Some instructions for installing the equipment must be followed.
2.4.1. Definition of Voltage Sampling Connector
PIN | Wire No. | Signal | Wire size (mm² ) | Remarks |
---|---|---|---|---|
1 | B0 | Signal | 0.3 | Cell #1- |
2 | B2+ | Signal | 0.3 | Cell #2+ |
3 | B4+ | Signal | 0.3 | Cell #4+ |
4 | B6+ | Signal | 0.3 | Cell #6+ |
5 | B8+ | Signal | 0.3 | Cell #8+ |
6 | B10+ | Signal | 0.3 | Cell #10+ |
7 | B12+ | Signal | 0.3 | Cell #12+ |
8 | B14+ | Signal | 0.3 | Cell #14+ |
9 | B16+ | Signal | 0.3 | Cell #16+ |
10 | NC | NC | NC | NC |
11 | B1+ | Signal | 0.3 | Cell #1+ |
12 | B3+ | Signal | 0.3 | Cell #3+ |
13 | B5+ | Signal | 0.3 | Cell #5+ |
14 | B7+ | Signal | 0.3 | Cell #7+ |
15 | B9+ | Signal | 0.3 | Cell #9+ |
16 | B11+ | Signal | 0.3 | Cell #11+ |
17 | B13+ | Signal | 0.3 | Cell #13+ |
18 | B15+ | Signal | 0.3 | Cell #15+ |
2.4.2. Definition of Temp. Sampling Connector
PIN | Wire No. | Signal | Wire size (mm²) | Remarks |
---|---|---|---|---|
1 | T1+ | Signal | 0.3 | Temp. #1+ |
2 | T2+ | Signal | 0.3 | Temp. #2+ |
3 | T3+ | Signal | 0.3 | Temp. #3+ |
4 | T4+ | Signal | 0.3 | Temp. #4+ |
5 | T1- | Signal | 0.3 | Temp. #1- |
6 | T2- | Signal | 0.3 | Temp. #2- |
7 | T3- | Signal | 0.3 | Temp. #3- |
8 | T4- | Signal | 0.3 | Temp. #4- |
2.4.3. Front View
Item | Name | Model | Remarks |
---|---|---|---|
1 | SOC LED x4 | ||
2 | Alarm LED | ||
3 | RUN LED | ||
4 | Dialer | ||
5 | Communication port | RJ11 | RS232 To upper machine |
6 | Communication port *2 | RJ45 | CAN To PCS RS485 Internal Connection |
7 | Reset | Waken system from malfunction status | |
8 | Dry Contact | ||
9 | Power On/Off Switch | ||
10 | Port Negative x2 | PSR6XAB | Black 5.7, 25mm2 |
11 | Port Positive x2 | PSR6XBB | Orange 5.7, 25mm2 |
--- | --- | --- | --- |
12 | GND | M6 | Yellow-Green, 10AWG |
2.4.4 Port RS485 and RS232
| Description
---|---
CAN| Pin 1: CAN-H Pin 5: CAN-L
Pin 2, 3, 4, 6, 7: NC
Pin 8: GND
RS485| Pin 1, 4, 5: NC Pin 2, 7: RS485-A Pin 3, 6: RS485-B Pin 8: GND
RS232| Pin 1, 2, 6: NC
Pin 3: BMS transmit; Computer receiver Pin 4: BMS receiver; Computer transmit
Pin 5: GND
Installation
3.1. DC Cable Requirements
Size | Outer Diameter | Max. Voltage | Max. Current |
---|---|---|---|
21-33 mm² | 10-12 mm | 1000 V | 120 A |
Caution
DC cable must be a multicore wire.
3.2. DC Cable
Danger
- Turn off system before doing electrical connection
- Ensure all the cables are in electrical safe condition
3.2.1 Material List
3.2.2 Steps
- Put wire through isolation cap and Tail Hood.
- Swipe outer isolation layer of DC cable .
- The is used for the positive, and the negative for tieback contact. The end of the cable is bunched at the terminal using a wire clamp.
- Tighten the isolation cap and plug contact.
- Put the positive and negative plug on to the system and tighten it.
- Use isolation cap for unused DC plug.
3.3. DC Cable Connection
3.3.1 Single Unit
3.3.2 Multi-Units in Parallel (4 sets as an example)
Master Pack and Slave Pack L051100-A can be used as single unit as well as
multi-units (inparallel) mode. The customer must inform supplier if multi-
units mode is required. The MasterPack can be used individually, but Slave
Pack cannot be used individually.
3.3.3. Method to set up Master Pack and Slave Pack
Master/slave machine dial code diagram:
Power ON and OFF
4.1. Instruction
Please double check the Precautions for use in section 1.3.
4.1.1 System Power ON
- Installation (including DC cable, communication wire connection and dialer switch) is properly down.
- Press Power Switch button, green LED should be twinkling and then turn into function mode. (system status can be red from LED signal, as shown below)
4.1.2. System Power OFF
Attention: It must be confirmed that the system is off before taking off DC
cables. Press Power Switch button
Green LED should be twinkling and then turn into stop mode
4.1.3. Sleep and wake up function
Number | Sleep Condition | Wake up Condition | Mark |
---|---|---|---|
1 | Forced sleep by upper computer | Reset button | |
**** 2 | **** Forced sleep by soft switch | **** Soft switch, | Only those |
equipped with soft switch can pass the call Wake up
3| Total Voltage is lower than 48V or monomer is lower than 2.8V, and
continuous No charge and discharge current for 4 hours, no communication goes
to sleep| Reset button, Soft switch, Communicatio n, Charging| Only
those equipped with soft switch can pass the call Wake up
4.1.4. Buzzer function
- 0.25s per 1s in case of fault
- 0.25s per 2S during protection
4.1.5. System Status Instruction
There are 6 LED indicator, 4 green LED gives status of SoC, 1 red Alarm LED
and 1 green Running Status LED (indicating charging, discharging etc.)
Status | Normal/Warning/Protection | RUN | ALM | SoC | Remarks |
---|---|---|---|---|---|
Power Off | Hibernate | no | no | no | no |
Standby | Normal | Twinkle 1 | no | Real SoC | Standby |
Warning | Twinkle 1 | no | |||
Charging | Normal 1Twinkle | 2 | no | ||
Warning | Twinkle 2 | no | |||
Overcharging | Twinkle 1 | no | Overcharing ALM no | ||
Overheat, Over-current, Low Temp. | Twinkle 1 | Twinkle 2 | |||
Discharging | Normal | Continuous | no | ||
Warning | Continuous | no | Over-current, ALM no | ||
Over discharging | Twinkle I | no | |||
Overheat, Low Temp., Over-cun ent Shortcut | Twinkle I | Twinkle 2 |
Charging/
Discharging/
Standby| Abnormal| Twinkle at current
state| Twinkle 3| If the slave is disconnected or disconnected, the slave ALM
light Twinkle;
Fault| no| Continuous| no| no| no| no| Fault refers to the hardware fault of
BMS voltage car yang device, charging MOS damage, temperature sensor
disconnection. etc
4.1.6 LED Twinkle Status
Status | On | Off |
---|---|---|
Twinkle 1 | 0.25S | 3.75S |
Twinkle 2 | 0.5S | 0.5S |
Twinkle 3 | 0.5S | 1.5S |
4.1.7. SoC indicator
SoC | LED |
---|---|
LED1 | LED2 |
0-25% | On |
25%-50% | On |
50%,-75% | On |
75%,w100% | On |
Transportation and Storage
5.1. Transportation
It is forbidden to encounter serious vibration and shock during
transportation.
5.2. Storage
If the system is not placed to use, the system must be properly stored.
Otherwise, if any issues, Sunsynk
- It should be stored in 60% SoC status.
- It should be stored at ventilation environment, Temp. < 35 deg C, RoH <65%.
- It should be stored avoiding humid condition.
- It should be stored in place where they can be monitored by professionals.
Disclaimer
It should be noted that Sunsynk shall not be liable if any necessary materials are added to this user’s manual without further inform of customers.
Global Tech China Ltd, 3 Floor, Wai Yip Industrial Building.171 Wai Yip
Street,
Kwun Tong, Kowloon, Hong Kong. Tel: +852 2884 4318 Fax:
+8522884 4816
www.sunsynk.com
sales@globaltech-china.com
www.globaltechhk.com
Documents / Resources
|
SUNSYNK L051100-A Power Lite Lithium Battery
System
[pdf] Owner's Manual
L051100-A, Power Lite Lithium Battery System, L051100-A Power Lite Lithium
Battery System, Lite Lithium Battery System, Lithium Battery System, Battery
System
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>