WELLFOR 28-in W x 36-in H LED Lighted Aluminum Rectangular Installation Guide

June 3, 2024
WELLFOR

WELLFOR-LOGO

WELLFOR 28-in W x 36-in H LED Lighted Aluminum Rectangular

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical furnishing, basic precautions should
always be followed,Requires two(2) person in installation. DANGER READ AND FOLLOW ALL INSTRUCTIONS BEFORE USING THIS MIRROR.
WARNING To reduce the risk of burns, fire, electric shock or injury to persons. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. Never drop or insert any object into any opening. Do not use outdoors.
WARNING Risk of electric shock. Connect this furnishing to a properly grounded circuit only. See Grounding instructions.

GROUNDING INSTRUCTIONS:

WARNING This product must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the product. An Electrical option cabinet must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.

NOTE: To ensure the normal use of the product, It is required to set out wires as per the regulations of lEE. Ihe product is only applicated to indoor installation. The installation must be executed by a professional electrician, wrong installation may lead to product damage and personal injury,

TOOLS REQUIRED FOR ASSEMBLY

WELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-
Rectangular-1

PARTS INCLUDED

WELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-
Rectangular-2

HARDWARE INCLUDED (not shown actual size)

WELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-
Rectangular-3

NOTE: Determine overall mirror dimensions before proceeding to installation.
“All dimensions & specifications are approximate and subject to change without notice. Accessories and parts may vary from the picture above.Depends on the product model and size.

ELECTRIC CONNECTIONS

ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENCED ELECTRICIAN

WARNING: Shut off power before wiring the mirror.
WARNING: An Electrical option mirror must be wired to a 20 Amp GFI (Ground Fault Interrupter) protected circuit when used in bathrooms and all other locations required by the National Electric Code.
WARNING: This mirror must be connected to a grounded, metal permanent wiring system or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the mirror.
CAUTION: Requires 120 VAC 20 Amp GFI protected circuit.

  • Electric wiring: Be sure to provide enough wire to make the proper and safe connection to the Field/Power.WELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-Rectangular-4
  • MIRROR FEATURESWELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-Rectangular-5
    • 4mm copper free silver mirror
    • High output LED lighting: CRI 90+, 6000K +500 CCT, IP44
    • Dimmable touch switch
    • Vertical and horizontal mount options
    • Defogger is seperate controlled

INSTALLATION INSTRUCTIONS

  1. PLACEMENT
    Choose to mount the mirror in either a vetical or horizontal orientation. Once the orientation is chosen measure the distance between the center of the keyholes in the mounting bracket.WELLFOR-28-in-W-x-36-in-H-LED-Lighted-
Aluminum-Rectangular-6

  2. SUPPORT LOCATION
    After measuring the distance between the keyholes on he mirror, mark the mounting points on the wall in the ppropriate spots. These marks should be the same distance apart as measured in step 1. Use a level to ensure the mounting points are straight.

  3. INSTALL SCREWS
    Using a drill, make holes on solid wall, and tighten mounting screws into the drywall anchors, leaving 3/8 in. space between the screw head and the wall.WELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-
Rectangular-8

  4. POWER OFF
    Please turn off all the power before the mirror wires connection.WELLFOR-28-in-W-x-36-in-H-LED-Lighted-Aluminum-
Rectangular-9

  5. CONNECTION
    Use the wire connector connect to external power supply, and pusing the power supply wires into the junction box.

  6. Turn on the power
    Insert the screw heads into the keyholes on the mirors mounting bracket, then carefully let the mirror drop down so the screw heads slide into the narrow ends of the keyholes, securing the mirror in place. Then turm on the power at the circuit breaker or reinsert the fuse.WELLFOR-28-in-W-x-36-in-H-LED-
Lighted-Aluminum-Rectangular-11

FINAL ASSEMBLY

How to use Defogger Switch and Dimmer Switch:

Left Touch Sensor
ON/OFF Anti-foggy(The power will automatically go off in an hour)

Right Touch Sensor
ON/OFF Lighting Brightness control by holdingON/OFF Anti-foggy(The power will automatically go off in an hour)

OPERATION

  1. Touch the sensor button to turn ON the light.
  2. Touch and hold the sensor button to dim the lightRelease the button when the light reaches the desired brightness setting.
  3. Touch the sensor button to turn OFF the light.

Suggestion: Turn off the mirror power supply if you don’t use it for a long time.

WARNINGS:

  1. Please do not use if you found the mirror have been broken.
  2. Never put any sharp or heavy material on the mirror surface, other wise the glass mirror will be broken and body injury accidents may occur.
  3. Turn off the power switch in storm lightning weather to avoid electric parts damage.

Use and Maintenance

CAUTION:

  • USE
1. To avoid damage, do NOT knock the mirror with any hard objects;
  • CLEANING
1. Do NOT clean the mirror with caustic cleaner. Do NOT wipe the mirror with Bristle brush;
  • MAINTENANCE
1. For daily maintenance, please use soft cloth and mild cleaner to clean the mirror.

LIMITED WARRANTY

LIMITED WARRANTY TWO YEARS TERM:
WELLFOR warrants to the original purchaser that, it will, at its election repair,replace, or make the appropriate adjustment to products made by this company shown to have significant defects in material or workmanship which are reported to WELLFOR in writing within two (2)years from the date of delivery. WELLFOR is not responsible for installation costs. The warranty is void in the event the product is damaged in transit, or if damage or failure is caused by abuse, misuse, abnormal usage, faulty installation, damage in an accident,improper maintenance,or any repairs other than those authorized by WELLFOR. At the expiration of the two years warranty period,WELLFOR shall be under no further obligation under any warranty, expressed or implied,including the implied warranty of merchantability. WELLFOR shall not be liable for any consequential damages arising out of or in connection with the use or performance of its products. Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.Any liability against WELLFOR under any implied warranty, including the warranty of merchantability, is expressly limited to the terms of this warranty. Permission to return any merchandise under this warranty must be authorized by WELLFOR and returned prepaid by the purchaser. Claims under this warranty should be sent directly to your dealer.

For customer support please call 206.809.0093 weekdays 9:00 to 6:00 PST, or by email at: service@wellfor.com.
For more information: www.wellfor.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WELLFOR User Manuals

Related Manuals