Altronix T3M77LXK1 Mercury Wired Kits Installation Guide

June 3, 2024
Altronix

Altronix T3M77LXK1 Mercury Wired Kits

Altronix-T3M77LXK1-Mercury-Wired-Kits-PRODUCT

Models Include

16 Door Kits with Fused Outputs: T3M77LXK1

  • Accommodates one (1) Intelligent Dual Reader Controller and seven (7) Dual Reader Interface Modules.

14 Door Kits with Fused Outputs: T3M77LXK2

  • Accommodates one (1) Intelligent Controller and seven (7) Dual Reader Interface Modules.

16 Door Kits with Fused Outputs: T3M77LXK3

  • Accommodates up to eight (8) Dual Reader Interface Modules.

Each fully assembled kit includes

  • Trove3 enclosure with TM3 Altronix/Mercury backplane
  • Two (2) AL1024ULXB2 – Power Supply/Charger
  • Two (2) ACMS8 – Dual Input/Output Fuse Protected Access Power Controller
  • Two (2) VR6 – Voltage Regulator
  • Two (2) PDS8 – Dual Input/Output Fuse Protected Power Distribution Module
  • One (1) Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL)
  • Wire harnesses and finger duct

16 Door Kits with PTC Outputs: T3M77LXK1D

  • Accommodates one (1) Intelligent Dual Reader Controller and seven (7) Dual Reader Interface Modules.

14 Door Kits with PTC Outputs: T3M77LXK2D

  • Accommodates one (1) Intelligent Controller and seven (7) Dual Reader Interface Modules.

16 Door Kits with PTC Outputs: T3M77LXK3D

  • Accommodates up to eight (8) Dual Reader Interface Modules.

Each fully assembled kit includes

  • Trove3 enclosure with TM3 Altronix/Mercury backplane
  • Two (2) AL1024ULXB2 – Power Supply/Charger
  • Two (2) ACMS8CB – Dual Input/Output PTC Protected Access Power Controller
  • Two (2) VR6 – Voltage Regulator
  • Two (2) PDS8CB – Dual Input/Output PTC Protected Power Distribution Module
  • One (1) Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL)
  • Wire harnesses and finger duct

All components of these Trove kits are UL Listed as sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information.

All registered trademarks are property of their respective owners.

Rev:  T3M77LXK0422

  • Installing Company: __
  • Service Rep. Name: __
  • Address: __
  • Phone #: _____

Overview

Altronix Trove Plus kits are pre-wired, and pre-assembled and consist of Trove3M3 enclosure/backplane with factory-installed Altronix power supply/ charger(s) and sub-assemblies, wire harnesses and finger duct.

Configuration Chart






Altronix

Model Number

| ****



115VAC

60Hz

Input Current (A)

| ****


Power Supply Board Input Fuse Rating

| ****


Power Supply Board Battery Fuse Rating

| Nominal DC Output Voltage| Maximum Supply Current for Main Outputs on Power Supply boards and ACMS8(CB)

Access Power Controller’s outputs

| Fail-Safe/Fail-Secure or Dry Form “C” Outputs| Current Per ACMS8 and PDS8(CB) Output (A)| ACMS8(CB) Board

Input Fuse (PTC) Rating

| ACMS8(CB) Board

Output Fuse (PTC) Rating

| PDS8(CB) Board Input Fuse Rating| PDS8(CB) Board Output Fuse (PTC) Rating
---|---|---|---|---|---|---|---|---|---|---|---
Power Supply 1| Power Supply 2


Output Range (VDC)

| ****

Output Range (VDC)

T3M77LXK1| ****




8.4

| ****




5A/

250V

| ****




15A/

32V

| ****




20.17-

26.4

| ****




20.17-

26.4

| ****




24VDC @ 9.4A

| ****




16

| ****


2.5

| ****

15A/

32V

| ****

3A/

32V

| ****

10A/

32V

| ****

3A/

32V

T3M77LXK2
T3M77LXK3
T3M77LXK1D| ****


2.0

| ****


9A

| ****


2.5A

| ****

10A/

32V

| ****


2.5A

T3M77LXK2D
T3M77LXK3D

Hardware and Accessories

  • Two (2) tamper switches (Altronix Model TS112 or equivalent).
  • Cam lock.
  • Battery leads.

Mechanical

  • 16 Gauge enclosure with ample knockouts for convenient access.
  • Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).

Installation Instructions

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only.

  1. Remove backplane from enclosure. Do not discard hardware.
  2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
  3. Mount included UL Listed tamper switches (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
  4. Mount Mercury boards to backplane, refer to pg. 3, 4.
  5. Refer to the ULXB Power Supply/Charger Installation Guide for AL1024ULXB2 and corresponding Sub-Assembly Installation Guides for PDS8(CB) and ACMS8(CB) for further installation instructions.
  6. Position Lenel/Mercury access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2-4, pg. 3-5).
  7. Mount backplane to enclosure with hardware.

T3M77LXK1

(T3M77LXK1D) Configuration

  1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2, pg. 3).
  2. Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models

LenelS2 / Mercury Access Controller Pem Mounting
LNL-2220 / LP1502 A
LNL-1320 / MR52 B

Altronix-T3M77LXK1-Mercury-Wired-Kits-FIG-2

T3M77LXK2 (T3M77LXK2D) Configuration

  1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
  2. Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models

LenelS2 / Mercury Access Controller Pem Mounting
LNL-3300 / LP2500 A
LNL-1320 / MR52 B

Altronix-T3M77LXK1-Mercury-Wired-Kits-FIG-3

T3M77LXK3 (T3M77LXK3D) Configuration

  1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 4, pg. 5).
  2. Mount backplane to enclosure with hardware.

Access Controller Position Chart for the Following Models

LenelS2 / Mercury Access Controller Pem Mounting
LNL-1320 / MR52 A

Altronix-T3M77LXK1-Mercury-Wired-Kits-FIG-4

TM3 Dimensions

  • 34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm)

Altronix-T3M77LXK1-Mercury-Wired-Kits-FIG-5

Trove3 Enclosure Dimensions (H x W x D approximate)

  • 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm)

Altronix-T3M77LXK1-Mercury-Wired-Kits-FIG-6

Altronix is not responsible for any typographical errors.

IIT3M77LXK Kit Series

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals