STAHL 133248 Ex e Junction Boxes Installation Guide
- June 3, 2024
- STAHL
Table of Contents
STAHL 133248 Ex e Junction Boxes
Installation Equipment
Ex e junction box
- Resistant Ex e enclosure, universally usable as connection or junction boxes and/ or to safeguard electric distributors up to 6.3 A
- IP66 degree of protection
- With mantle terminals or with a combination of mantle terminals and miniature fuses (optional)
WebCode 8118A
R. STAHL Series 8118 junction boxes are equipped with 4, 5 or 8 mantle terminals depending on their design size. As an option, miniature fuses can still be installed in addition. Junction boxes are therefore also suitable for safeguarding. The robust enclosure made from glass fibre reinforced polyester resin can be equipped with plastic or metal cable glands.
Technical Data
Explosion Protection
Scope of validity| European Union (ATEX)
IECEx
Application range (zones)| 1
2
21
22
IECEx gas certificate| IECEx PTB 06.0026
IECEx gas explosion protection| Ex eb IIC T6 … T5 Gb
IECEx dust certificate| IECEx PTB 06.0026
IECEx dust explosion protection| Ex tb IIIC T80 °C / T95 °C Db
ATEX gas certificate| PTB 99 ATEX 3103
ATEX gas explosion protection| E II 2 G Ex eb IIC T6 … T5 Gb
ATEX dust certificate| PTB 99 ATEX 3103
ATEX dust explosion protection| E II 2 D Ex tb IIIC T80 °C / T95 °C Db
Certificates| ATEX (PTB), Brazil (ULB), China (NEPSI), EAC (ENDCE), IECEx
(PTB), Korea (KGS)
Ship approval| BVIS
Explosion protection note| For product label, see skope of validity.
Electrical Data
Permissible rated operational current with 5 loaded terminals| for conductor
cross-section 1.5 mm²: 13 A for conductor cross-section 2.5 mm²: 18 A
for conductor cross-section 4 mm²: 24 A
Permissible rated operational current with 4 loaded terminals| for conductor cross-section 1.5 mm²: 15 A for conductor cross-section 2.5 mm²: 19 A
for conductor cross-section 4 mm²: 25 A
Permissible rated operational current with
≤ 3 loaded terminals
| for conductor cross-section 1.5 mm²: 16 A for conductor cross-section 2.5 mm²: 20 A
for conductor cross-section 4 mm²: 25 A
Ambient Conditions
Ambient temperature| -60 °C … +40 °C (T6)
-60 °C … +55 °C (T5)
Ambient temperature| -76°F … +104°F (T6)
-76°F … +131°F (T5)
Mechanical Data
IP degree of protection (IEC 60529)| IP66
Enclosure material| Polyester resin, Glass fibre reinforced
Enclosure colour| Dark grey
Flammability according to| IEC/EN 60695
UL 94
ASTM D635
Silicone-free| No
Connection cross-section| 4 mm²
Permissible number of conductors per clamping unit, solid| mantle terminal M7
x 0.75
conductor cross-section 1.5 mm²: number of conductors min. 2, max. 4
conductor cross-section 2.5 mm²: number of conductors min. 2, max. 2
Permissible number of conductors per clamping unit, finely stranded prepared,
core end sleeve crimped
| mantle terminal M7 x 0.75
conductor cross-section 1.5 mm²: number of conductors min. 2, max. 3
conductor cross-section 2.5 mm²: number of conductors min. 2, max. 2
Permissible number of conductors per clamping unit, finely stranded unprepared| mantle terminal M7 x 0.75
conductor cross-section 1.5 mm²: number of conductors min. 2, max. 3
conductor cross-section 2.5 mm²: number of conductors min. 2, max. 2
Permissible number of conductors per
clamping unit note
| All conductors of a terminal must have identical cross sections and
identical material.
Cover| Screw-on cover
Cover fixing type| M4 stainless steel screws, With captive screws
Width| 85 mm
Width, inches| 3.35 in
Height| 85 mm
Height, inches| 3.35 in
Depth| 55 mm
Depth, inches| 2.17 in
Packaging unit| 1
Weight| 0.3 kg
Weight| 0.66 lb
Mounting / Installation
Tightening torque of cover screw 1| 1.4 Nm
Cover screw 1 tightening torque lbf in| 12.4 lbf in
Components
Entry 1| 3 x 8161/7-M20-1304-LT
(Provided separately)
Entry 1 type| Polyamide cable gland, black
Entry 1| M20 x 1.5
Entry 1 terminal area| 4 – 13 mm
Entry 1 clamping range, inch| 0.16 – 0.51 in
Metal entry possible 1| No
Components
Entry 2| 1 x 8290/3-M20
(Provided separately)
Entry 2 type| Polyamide stopping plug
Entry 2| M20 x 1.5
Metal entry possible 2| No
Entries installation options/side| Size 1: 4x M20 (A+B+C+D)
Type of terminals 1| 5 x Mantle terminal
4 mm²
Technical Drawings – Subject to Alterations
Dimensional Drawings (All Dimensions in mm [inches]) – Subject to
Alterations
- Length L
- protrusion length for cable glands, Series 8161
- in case of M20: 25 … 31 [0.98 … 1.22]
- in case of M25: 27 … 33 [1.06 … 1.3]
- in case of M32: 32 … 39 [1.26 … 1.54]
- protrusion length for cable glands with strain relief, Series HSK-K-MZ
- in case of M25: 41 [1,61]
Accessories
Cable gland made of | plastic | Art. No. |
---|---|---|
**** | 8161/7-M20-1307-LT, Ex e |
Plastic, M20 x 1.5, cable outer diameter 7 to 13 mm Lot size 50 pieces
| 239204
Stopping plug
| 8290/3-M20
Plastic, M20 x 1.5 Lot size 100 pieces
| 285773
---|---|---
Brass plate with thread
****| 8118 size 1, plate 37 x 30 mm [1.46 x 1.18″] 1 x M20 x 1.5 with M4 PE connection (left)
for installation in enclosure size 1, size 2 and size 3
| 168913
---|---|---
****| 8118 size 1, plate 37 x 30 mm [1.46 x 1.18″] 1 x M20 x 1.5 with M4 PE
connection (right)
for installation in enclosure size 1, size 2 and size 3
| 168914
---|---|---
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding2022-11-25 R. STAHL Schaltgeräte GmbH | Am Bahnhof 30 | 74638 WALDENBURG 4/4 Tel. +49 7942 943 1700 | +49 7942 943 1777 | Email: sales.de@r-stahl.com | r-stahl.com
References
- R. STAHL | Explosion Hazard Systems | Industrial Explosion Protection
- You will find a little bit of Stahl chemistry everywhere | Stahl | Stahl
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>