SpeCtra 9 Plus Electric Breast Pumap Instruction Manual
- June 3, 2024
- Spectra
Table of Contents
- Important Safety Information
- Important Symbol
- Indication for use
- Pumping Guide
- Parts & Assembly
- How to use Spectra 9 Plus breast pump
- LCD Screen and Control Button
- Battery information
- How to use double pump
- Cleaning and disinfection
- How to store breast milk?
- How do I thaw and use stored breast milk?
- Troubleshooting
- Use and Storage environment
- Specifications
- LIMITED WARRANTY
- WARRANTY CARD
- European Authorized Representative
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SpeCtra 9 Plus Electric Breast Pumap Instruction Manual
Important Safety Information
READ ALL INSTRUCTIONS BEFORE USING.
When using electrical products, basic safety precautions should always be
followed
To reduce the risk of electrocution.
- DO NOT USE WHILE BATHING.
- DO NOT PLACE OR STORE PRODUCT WHERE IT CAN FALL OR BE PULLED.
- DO NOT PLACE IN OR DROP INTO WATER OR OTHER LIQUOD.
- DO NOT REACH FOR A PRODUCT THAT HAS FALLEN INTO WATER, UNPLUG THE PRODUCT IMMEDIATELY. 5 DO NOT EXCEED
- MINUTES IN MICROWAVE, NEVER IMMERSE MAIN BODY IN WATER
To reduce the risk of burns, electrocution, fire, or injury to persons.
- THIS PRODUCT SHOULD NEVER BE LEFT UNATTENDED WHEN PLUGED IN.
- CLOSE SUPERVISTION IN NECESSARY WHEN THIS PRODUCT IS USED NEAR INFANTS OR CHILDEN.
- USE THIS PRODUCT ONLY FOR ITS INTENDED USE AS DESCRIBED IN THIS MANUAL. DO NOT USE ATTACHMENTS NOT RECOMMENDED BY THE UZINMEDICARE CO.
- NEVER OPERATE THIS PRODUCT IF IT HAS A DAMAGED CORD OR PLUG. IF IT IS NOT WORKING PROPERLY, IF IT HAS BEEN DROPPED OR DAMAGED. DROPPED INTO WATER, OR IF ANY PARTS ARE BROKEN OR MISSING.
- KEEP THE CORD AWAY FROM HEATED SURFACES.
- NEVER USE WHILE SLEEPING OR DROWSY.
- DO NOT USE OUTDOORS OR OPERATE WHERE AEROSOL SPRAY. PRODUCTS ARE BEING USED OR WHERE OXYGEN IS BEING ADMINISTERED.
- THE AC/DC ADAPTOR CORD SHOULD BE UNPLUGGED FROM THE OUTLET WHEN NOT IN USE.
- DO NOT DISASSEMBLE OR MODIFY THE PRODUCT.
- DO NOT INHALE OR SWALLOW SMALL PARTS II ALLERGIC REACTIONS MAY OCCUR
- LINT, DUST, LIGHT (INCLUDING SUNLIGHT), ETC CAN BE ADVERSELY AFFECT SAFETY AND ESSENTIAL PERFORMANCE.
- AC/DC ADAPTOR MUST BE EASY TO UNPLUG POSITION DURING USAGE. If you feel pain in your breast or nipple, turn the pump off or adapter plug out and remove from your breast. Consult your healthcare professional (Suction can be broken by inserting finger between the breast and breast shield or by shutting the pump off)
Important Symbol
WARNING!
This is designed to be a personal use product. Use of this breast pump by any
other than the original owner presents health and performance risks and void
the product warranty.
Indication for use
This is a powered breast pump to be used by lactating women to express and collect milk from their breasts. This is intended for a single user.
Pumping Guide
-
Center the assembled breast shields over your nipples. It is important that your nipples are drawn evenly into the center of the flange and not distorted in any way.
-
Press the on/off button and press massage button “Massage button symbol” for massage mode before pumping.
-
The massage mode will encourage the letdown reflex which triggers the start of milk flow
TIP —to help letdown, try a warm compress on the breast before pumping, thinking about your baby and most of all, relaxing, will help you to letdown your milk when expressing. Massaging the upper area of your breast can also assist draining the breast -
Once your milk starts to flow, press the massage button again to switch to expression mode.
-
Adjust the vacuum and cycle to find your preferred setting.
-
Express milk from each breast for 10-15 minutes. If single pumping, then alternate breasts.
-
Turn pump off after few seconds later when pumping finished,
TIP – It is more effective to pump for a shorter time at more frequent
intervals than to pump for a longer time at wider intervals. If exclusively
pumping, we suggest pumping every 2-3 hours, at least 8 times a day to
maintain supply.
NOTE : EVEN WHEN YOU ARE USING THE BREAST PUMP, BREASTFEED YOUR BABY
WHENEVER YOU CAN.
Always breastfeed your baby directly when you can, even when using this
product. Ask your healthcare provider for personalised advice for your
situation
Parts & Assembly
How to assemble Back-flow protector.
- Insert silicone membrane into lower protector.
- Insert upper case into silicone membrane assembled.
-
How to Disassemble
-
**Parts name
**
After holding the lower case of protector by thumb like above picture 1, full the upper case to direction of the arrow for disassemble.
How to use Spectra 9 Plus breast pump
- Clean the kit and connect the power.
- Connect the tubing to the breast shield and assemble the bottle onto the breast shield.
- Set the vacuum power to the lowerst position.
- Set the nipple in the center of the breast shield and turn the unit on.
- Adjust the suction strength properly.
- Turn the kit off after use
LCD Screen and Control Button
Battery information
The battery used in this device may present a risk of fire or chemical bum if
mistreated. Do not disassemble, heat or incinerate.
Do not disassemble and do not dispose of in fire.
Battery Spec | Li-Polymer 7.4V — 900mAh |
---|---|
3 LED bar Battery indicator on display | Operating 2 hours |
1 bar Battery indicator on display | Operation half hour |
Battery indicator flashes | Operation less than 30 minutes, it needs charging |
How to use double pump
Cleaning and disinfection
First time use
Sterilise all parts of the breast shield kit excluding the tubing using your
preferred sterilisation method. You do not need to sterilise the tubing as it
will not be in contact with your breastmilk. Do not sterilise the pump body.
Subsequent use
Disassemble and wash all parts of your breast shield kit that come into
contact with your breast and breastmilk and wash in warm soapy water, then
rinse in dean water and airdry. Keep parts covered when not in use.
Baby feeding components that are used with breastmilk do not need sterilisation after every use. however you may wish to sterilise every few uses as a hygiene precaution and to remove fat residue.
All parts are dishwasher safe.
If required, the pump body can be cleaned with a damp(not wet) cloth.
NOTE : TO ELIMINATE CONDENSATION OR MILK IN THE TUBING, WASH AND DRY IT IMMEDIATELY. TO CLEAN MAIN BODY, WIPE MAIN BODY WITH A CLEAN DAMP CLOTH.
How to store breast milk?
- Make sure your hands are clean and dry before handling expressed breastmilk.
- Storage containers should be sterilised before being used to store breastmilk. If you intend to store your breastmilk in the same bottle or container you have expressed into, ensure it is sterilised before use. Spectra milk storage bags are presterilised.
- Try not to touch the insides of the storage containers
- Seal the container with a solid lid or secure the ziplock seal if using Spectra milk storage bags. Label each container with the date the milk was pumped.
- Breast milk that will be frozen should have at least one inch between the milk and the container lid. Frozen milk expands as it freezes.
- Store milk away the freezer or refrigerator door to avoid changes in temperature that may compromise the milk
How long can I store breast milk?
At Room Temperature:
Temperature | Storage Time |
---|---|
15°C (60°F) | 24 hours |
26°C (79°F) | 4 to 6 hours |
30°C (86°F) | 4 hours |
In the Refrigerator:
Temperature | Storage Time |
---|---|
0°C-4°C (32°F-39°F) | Up to 8 days |
In the Freezer:
Type | Storage Time |
---|
Compartment
Contained within a refrigerator| Up to 2 weeks
Self-Contained
Bottom, top mount, side-by-side, or stand alone freezer| 3 to 4 months
Deep Freezer
With a constant -17°C (0°F) temperature| 6 to 12 months
Source: Breastfeeding Made Easier at Home and Work, womensheatth.gov
How do I thaw and use stored breast milk?
- Always make sure to check the date on the milk’s container before using. Do not use undated milk, or milk that has been stored too long.
- Thaw frozen milk in the refrigerator or under cool, running water.
- Heat the milk under warm, running water and gently swirl the container to mix the milk.
- If warm water is not available, heat a pan of water on the stove. Once the water is warm, not boiling, remove the pan from the stove and place the milk container in the pan. Never warm the milk container directly on the stove.
- Never microwave breast milk because microwaves can cause dangerous hot spots that could burn you or a baby.
- Always test the temperature of the milk on the inside of your wrist before feeding it to a baby. The milk should feel warm, not hot.
- After thawing, milk should be stored in the refrigerator for no more than 24 hours. Never refreeze thawed milk. Throw away previously frozen milk that is not used within 24 hours.
Troubleshooting
Condition | Possible Causes | Checks | Solutions |
---|---|---|---|
Not working | Adaptor | Check if the power cord is not connected or it has | |
damaged. | Plug into the outlet. If it has damaged. Contact manufacturer Or |
service center or where you purchased.
Dead battery| Check after charged.| If it doesn’t charge, Contact manufacturer
or service center or where you purchased.
No suction| Air tube| Check the air tube is connected to the main body.|
Connect the air tube to the main body.
Valve| Check if they are connected to
breast shield properly.
| Disassemble and reassemble them property.
Air cap| Check
closed. if the air cap is| Close sine air cap Close
Low suction| Vacuum Level| Check if there is a tow vacuum level on the vacuum
regulator valve or if there is an abnormal noise.| Contact the location where
you purchased the product or the manufacturer.
Defective assembly kit| Check the connection of the kit.| Disassemble and
reassemble them.
Breast shield| Check if there is problem with the breast shield| Purchase and
replace the breast shield.
Valve head| Check if there is damaged in valve head.| Replace the valve head.
Pain| Too high suction| Check the suction level| Set to the lowest suction
level and consult your lactation consultant or physician.
Use and Storage environment
Specifications
Model : Spectra 9plus
Protection Type : Class II
Weight : 290g
Adaptor
Manufacturer: Dongguan Shilong FuhuaElectronic Co.,Ltd.
Model No:U ES18LCP-090140SPA
Input: 100-240V-,-50/60Hz, 500mA
Output: 9V 1.4 A
Battery: Li-Polymer 7.4V 900mAh
- Type of protection against electric shock: Class II equipment
- Degree of protection against electric shock: Type BF applied parts
- Classification according to the degree of protection against ingress of water: IP22
- This equipment is not suitable for use in the presence of flammable anesthetics or oxygen. 5. Mode of operation: Continuous.
LIMITED WARRANTY
This is designed to be a personal use product. Using breast pump by any other
than the original owner presents health and performance risks and void the
product warranty This product is warranted by Uzinmedicare Co.,Ltd to the
original retail purchaser to be free from defects in material and workmanship
for the period of 2 years.
This warranty does not cover damage caused by accident, misuse, abuse,
improper maintenance, unauthorized modification, or connection to an improper
power supply. A charge will be made for repair of such damages.
WARRANTY CARD
Spectra 9 Plus
Origin : Republic of Korea
Address : 54, 56, Dongtansandan 5-gil, Hwaseong-si, Gyeonggi-do, 18487,
Republic of Korea
Telephone :+82-70-5228-0983
Spectra 9 Plus Rechargeable Breast Pump
Name|
Telephone|
Mobile Phone|
Address|
European Authorized Representative
Obelis s.a
Bd. Gnral Wahis, 53, 1030 Brussels, Belgium Tel +32(0)2 732 59 54 Fax +32(0)2
732 60 03 E-mail : mail@obelis.net
Uzinmedicare Co., Ltd.
54,56, Dongtansandan 5-gil, Hwaseong-si, Gyeonggi-do,18487, Republic of Korea
Tel :+82-70-5228-0983 / www.uzinmedicare.com
Read User Manual Online (PDF format)